EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LG
  6. •
  7. Air Conditioner
  8. •
  9. LG PHNFP14A0 User manual

LG PHNFP14A0 User manual

Other manuals for PHNFP14A0

3

This manual suits for next models

1

Other LG Air Conditioner manuals

LG LT-D5480HL User manual

LG

LG LT-D5480HL User manual

LG E12EM User manual

LG

LG E12EM User manual

LG LSN-LSU-90-120HYV User manual

LG

LG LSN-LSU-90-120HYV User manual

LG LMNC126LRL0 User manual

LG

LG LMNC126LRL0 User manual

LG P121CM Instruction Manual

LG

LG P121CM Instruction Manual

LG ASN30BA User manual

LG

LG ASN30BA User manual

LG ARNU153BHA2 User manual

LG

LG ARNU153BHA2 User manual

LG ARNU183TLC2 User manual

LG

LG ARNU183TLC2 User manual

LG LSU5AU2A User manual

LG

LG LSU5AU2A User manual

LG AC Smart 5 PACS5A000 User manual

LG

LG AC Smart 5 PACS5A000 User manual

LG AMNW07GSJA0 User manual

LG

LG AMNW07GSJA0 User manual

LG ARND153DCR4 User manual

LG

LG ARND153DCR4 User manual

LG LW1013CR Assembly instructions

LG

LG LW1013CR Assembly instructions

LG TERMINATOR SN05ICEX User manual

LG

LG TERMINATOR SN05ICEX User manual

LG LS240HSV3 User manual

LG

LG LS240HSV3 User manual

LG UV12 User manual

LG

LG UV12 User manual

LG ATNQ18GPLE7 User manual

LG

LG ATNQ18GPLE7 User manual

LG ARUB80LT3 User manual

LG

LG ARUB80LT3 User manual

LG JTNQ36GNLE5 User manual

LG

LG JTNQ36GNLE5 User manual

LG ARNH08GK3A2 User manual

LG

LG ARNH08GK3A2 User manual

LG HSNC096QDA3 User manual

LG

LG HSNC096QDA3 User manual

LG ANNQ60GKA4 User manual

LG

LG ANNQ60GKA4 User manual

LG S12KWH User manual

LG

LG S12KWH User manual

LG ASNW096H4A0 User manual

LG

LG ASNW096H4A0 User manual

Popular Air Conditioner manuals by other brands

Panasonic CS-E12HKEW operating instructions

Panasonic

Panasonic CS-E12HKEW operating instructions

Mitsubishi Electric MSZ-GE60VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE60VA null

Samsung AVMFC052EA0(4) null

Samsung

Samsung AVMFC052EA0(4) null

Haier HSU-09H03/R null

Haier

Haier HSU-09H03/R null

Haier HSU-24C03 null

Haier

Haier HSU-24C03 null

Mitsubishi Electric MSZ-GE22VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE22VA null

Samsung AVMCH052CA1 null

Samsung

Samsung AVMCH052CA1 null

nedis ACMB1WT7 quick start guide

nedis

nedis ACMB1WT7 quick start guide

Daikin FCFV50A Operation manual

Daikin

Daikin FCFV50A Operation manual

Fujitsu Inverter ASBA30JFC operating manual

Fujitsu

Fujitsu Inverter ASBA30JFC operating manual

Toshiba RAS-M10SMUV-E installation manual

Toshiba

Toshiba RAS-M10SMUV-E installation manual

Daikin FXLQ20MAVE Operation manual

Daikin

Daikin FXLQ20MAVE Operation manual

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

CIAT

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron AAC6000 instruction manual

Bestron

Bestron AAC6000 instruction manual

Frigidaire FFRE0533S1E0 Use & care guide

Frigidaire

Frigidaire FFRE0533S1E0 Use & care guide

Samsung AS09HM3N user manual

Samsung

Samsung AS09HM3N user manual

Frigidaire CRA073PU11 use & care

Frigidaire

Frigidaire CRA073PU11 use & care

Soleus Air GB-PAC-08E4 operating instructions

Soleus Air

Soleus Air GB-PAC-08E4 operating instructions

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

www.lg.com
INSTALLATION MANUAL
AIR
CONDITIONER
PHNFP14A0 / PSNFP14A0
PI485 Gateway(C, R)
Please read this installation manual completely before installing
the product.
Installation work must be performed in accordance with the
national wiring standards by authorized personnel only.
Please retain this installation manual for future reference after
reading it thoroughly.
P/NO : MFL69265507
ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
PORTUGUESE
MAGYAR
БЪЛГАРСKN
SRPSKI HRVATSKI SVENDKA NORSK SUOMI DANSK
EESTI KEEL
MALTI
SLOVENČINA
SLOVENŠČINA
LATVIEŠU VALODA
LIETUVIŲ KALBA
GAEILGE
МАКЕДОНСКИ
SHQIP
ÍSLENSKA BOSANSKI
Safety Precautions
2485 Gateway(C, R) Installation Manual 3
ENGLISH
PI 485 INSTALLATION MANUAL
TABLE OF CONTENTS
nSafety Precautions....................................................3~4
nPart Description .......................................................5~6
nInstallation Guide ....................................................7~12
nInstallation Steps .................................................................................7
nDIP Switch Configuration.................................................................8~9
nAdvanced Lock Control Type ...........................................................10
nCentral Controller Connection Diagram.............................................11
nExamples For Product Installation.....................................................12
nAccessory Parts .........................................................13
Don't touch with the
hands while the power is
on
•
There is risk of fire or electric
shock.
Use standard
parts(connector).
•
Do not disassemble or repair
the product. There is risk of fire
or electric shock.
For electrical work, contact
the dealer, seller, a qualified
electrician, or an Authorized
Service Center.
•
Do not disassemble or repair
the product. There is risk of fire
or electric shock.
nInstallation
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
nIncorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
nMeanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
Be sure not to do.
Be sure to follow the instruction.
WARNING
Safety Precautions Part Description
4485 Gateway(C, R) Installation Manual 5
ENGLISH
Part Description
PHNFP14A0
PI485 GATEWAY(C)
BUS_B: RS-485 (-) Terminal
BUS_A: RS-485 (+) Terminal
Reset Switch: PI485(C) Reset
LED01G,02G,03G: Communication Status LED
LED1: RS-485 Communication Status LED
CN_OUT: Indoor Unit Connector
DIP Switch: Product Selection (Refer Page 8~10)
1
2
4
5
6
7
3
L1 2 3 4
When the product is soaked (flooded or
submerged), contact an Authorized Service
Center.
• There is risk of fire or electric shock.
Be cautious that water could not enter the
product.
• There is risk of fire, electric shock, or product
damage.
nOperation
Use the correctly rated
breaker or fuse.
• There is risk of fire or electric
shock.
Do not install, remove, or re-
install the unit by yourself
(customer).
• There is risk of fire, electric
shock, explosion, or injury.
For installation, always
contact the dealer or an
Authorized Service Center.
• There is risk of fire, electric
shock, explosion, or injury.
1
2
3
4
5
6
7
Installation Manual 7
Installation Guide
Installation Steps (PHNFP14A0/PSNFP14A0)
1. Select DIP Switch Configuration(Refer page 8 ~ 10)
2. Connect RS-485 BUS_A(+), BUS_(B)(-) with other network products (ex.
Simple Central Controller , ACP.....)
3. Connect CN_OUT with Indoor Unit by the cable (provided)
4. Check the Communication Status LED
- LED1G(Red)
• OK operation : LED blinks for 5 times and then gets OFF
This process is repeated after every 3 minutes
• NG operation : Check the Indoor Unit°Øs address & wiring connections
- LED2G(Yellow), LED3G(Orange)
• NG operation : Check the DIP Switch setting & wiring connections
5. Check RS-485
nOK operation :
(1) LED blinks when PI485 receives data from central controller.
nNG operation : Check the wiring connections
6. Finally if all of the above steps are OK then tie the cables by tie wraps & clamp
Installation Guide
6
7
4
5
1
2
6485 Gateway(C, R)
ENGLISH
Part Description
PSNFP14A0
PI485 GATEWAY(R)
BUS_B: RS-485 (-) Terminal
BUS_A: RS-485 (+) Terminal
Reset Switch: PI485(R) Reset
LED01G,02G,03G: Communication Status LED
LED1: RS-485 Communication Status LED
CN_OUT: Indoor Unit Connector
DIP Switch: Product Selection (Refer Page 8~10)
6
7
2
5
3
1
4
L1 2 3 4
1
2
3
4
5
6
7
Installation Manual 98 485 Gateway(C, R)
ENGLISH
Installation Guide
L1 2 3 4
L1 2
KSD42H
34
Select Air
Conditioner Type
Select Advanced
Control Type Select Network
Type
L1 2
KSD42H
34
L1 2
KSD42H
34
3 ON+ALL OFF: LGAP RAC/SRAC/PAC Products + Central Controller
(ALL type)-Without LGAP
3, 4 ON+ALL OFF: LGAP RAC/SRAC/PAC Products + Central
Controller (ALL type)-Using LGAP
For RAC/SRAC/PAC products using LGAP
• PSNFP14A0
CAUTION:
Wrong products configuration can lead to malfunctioning
Installation Guide
L1 2
KSD42H
34
Select Air
Conditioner Type
Select Advanced
Control Type Select Network
Type
L1 2 3 4
L1 2
KSD42H
34
L1 2
KSD42H
34
DIP Switch Configuration
3 ON+ALL OFF: Using LGAP CAC Products + Central Controller
3, 4 ON+ALL OFF: LGAP CAC Products + Central Controller (ALL
type)-Using LGAP
For CAC products using LGAP
hThis means Central controller type (Central controller using LGAP is under development.
Next generation controller would use LGAP.)
• PHNFP14A0
CAUTION:
Wrong products configuration can lead to malfunction.
The wrong setting of air-conditioner switch could cause malfunctioning.
Switch setting must be done carefully.
Installation Manual 11
Installation Guide
L1 2 3 4
Indoor unit main PCB
Centrol Controller
PI485 Gateway PCB
L1 2 3 4
Indoor unit main PCB
PI485 Gateway PCB
Centrol Controller
Central Controller Connection Diagram
CAUTION:
After product installation, tie the cables with the clamps & tie-wraps provided.
• PHNFP14A0
• PSNFP14A0
Installation Guide
10 485 Gateway(C, R)
ENGLISH
Advanced Lock Control Type
L1 2
KSD42H
34
‘2,3,4 ON+All OFF : LGAP CAC/RAC/SRAC Products + Central
Controller (All types) - Using LGAP
- To use the advanced lock function (Run Mode lock, Fan Speed lock,
Temperature Lock, and Temperature Range lock; adjustable only within certain boundary)
by central controller, Set up the second dip switch according to the type of outdoor product.
- In case of advanced lock function, it can use only the central controller applied to LGAP.
CAUTION:
The wrong setting of air-conditioner switch could cause malfunctioning.
Switch setting must be done carefully.
After setting the dip switch, PI485 must be reset
NOTE : The advanced lock setting
Some products do not support advanced lock function.
In this case, The second dip switch on PI485 must be on.
In case of product applied to advanced function, it can process the advanced lock function without second dip
switch ON.
If all units support advanced lock function,
It is recommended that the second dip switch be off, so that advanced lock function is processed faster.
Accessory Parts
Installation Manual 1312 485 Gateway(C, R)
ENGLISH
Installation Guide
Examples For Product Installation
CAUTION:
Installation location can be different depending upon product's structure.
(1) The Installation for 4Way Cassette
Product
’Check Screw boss for PCB in 4way
Cassette Product then fix it.
(2) The Installation for DUCT Product
’Using PCB Holder provided
(3) The Installation for Cassette Product
Cover
’Check Screw boss for PCB in 4way
Cassette Product Then fix It
Accessory Parts
PCB :6871A20484H Holder for DUCT :3110A 20056A WIRE ASSY 1(for RAC/SRAC/CAC)
Screw 4 EA Installation Manual WIRE ASSY(for Others)
PCB :6871A20484C
WIRE ASSY 1(for RAC/SRAC/CAC)
WIRE ASSY(for Others) Top Case(3110A20124A)
Screw 4 EA Installation Manual
Bottom Case(3110A20125A)
PI485
L1 2 3 4
L1 2 3 4
* Others : Tie Wrap (3 EA) - Cable Tie
Clamp (1 EA)
• PSNFP14A0
• PHNFP14A0
Representative
:
LG Electronics Inc. EU Representative, Krijgsman 1, 1186
DM Amstelveen, The Netherlands
Manufacturer
:
LG Electronics Inc. Changwon 2nd factory, 84, Wanam-ro,
Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA