LI-600N Porometer/Fluorometer Quick Start Guide
Online Resources
Computer
Software Configuration and data management, calibration, barcode generator: licor.com/600Nsoftware
Support Manual, software, videos,FAQs, tech tips, application notes, and more: licor.com/600Nsupport
Instruction
Manual Comprehensive instructions, operating theory, and maintenance:licor.com/600Nmanual
1Chamber. Active measurement site
2Porometer. Measures stomatal conductance
3Fluorometer. Measures PAM chlorophyll afluorescence
4Enter button. Powers on, selects options, initiates or
logs a measurement
5USB port. Charges and connects to a computer with a
micro-USB cable
Charge the battery
The LI-600N arrives partially charged. Connect the LI-600N to a power source with the USB cable and charge to 100%.
Take a measurement
The following instructions are for the gsw+F configuration preloaded on the instrument.
Step 1: Press and hold the Enter button to power on the LI-600N.
Step 2: Select the preloaded gsw+F configuration and press the Enter button.
Step 3: The LI-600N will enter match mode. Respond to the prompt. When matched, it will beep and go to the Measurements screen.
Step 4: Clamp to a needle or leaf. Watch for stability in the gsw variable. Press the Enter button (Log) to log the measurement when gsw is
stable. After the LI-600N displays Logged and beeps, unclamp the needle or leaf. View the data from the measurement on the screen.
Step 5: Press the Enter button (New) to start another measurement, or press the left arrow twice to navigate to Settings to Shutdown.
Step 6: Download the data. Install the LI-600N computer software. Connect the LI-600N to the computer via USB and download the data to
the computer software. Export the data from the software as a .zip file that contains .csv and Excel files.
Workflow for taking a measurement
The workflow for taking a measurement varies depending on the configuration. The following is for gsw+F with prompt on log disabled. See the
user manual for detailed instructions on those settings.
2
1
Select a configuration
and press the Enter
button.
3
When finished, press
the left arrow twice,
select Shutdown and
press the Enter
button.
Select Configuration
gsw+F
gsw+F+prompt
---
---
gsw+F
Shutdown
Match
Instrument Settings
Settings
Warning(s)
Prompt
Log
Home
leak_pct Qamb
F
PhiPS2
flr2sec
gsw
gsw2sec
Tleaf
LI-600N
LI-600N
Cancel
RH_adj
Matching.
Do not clamp on leaf.
flow RH_delta
flow_s
!
LI-600N
Answer any prompts:
highlight the answer
and press the Enter
button.
4 5
Settings Info Home
Home New
LI-600N
Mark
leak_pct Qamb
F
PhiPS2
flr2sec
gsw
gsw2sec
Tleaf
Clamp onto a needle
or leaf, watch for
stability, then press
the Enter button (Log).
Press the Enter button
(New) to initiate
another measure-
ment, and repeat from
step 3,
Measurement techniques
lAlign the needle or leaf with the opening in the aperture. If they are not aligned, the IRT sensor will not accurately measure the
sample.
lMaintain the light conditions of the leaf. Do not alter the light or shade the leaf you are measuring. If, while taking a measurement,
you shade the leaf you plan to measure next, unshade the leaf and wait 60 seconds before measuring it. Changes to light at the leaf sur-
face will affect PhiPSII and gsw.
lMatch the quantum sensor's light conditions to those of the leaf. If the leaf you measure is in the light, ensure that the quantum
sensor is also in the light. If the leaf you measure is in shade, ensure that the quantum sensor is also in the shade. A mismatch between
the leaf and the quantum sensor may result in a significant error in ETRcalculation.
lAvoid measuring a needle or leaf with water on it. If the needle or leaf you plan to measure has water or condensation on it, gently
and thoroughly dry it. Measuring a wet needle or leaf may result in overestimation of stomatal conductance, and water ingress into the
instrument may cause damage.
Copyright © 2023 LI-COR, Inc.
All rights reserved.
984-20614•10/2023
LI-COR Biosciences
4647 Superior Street
Lincoln, Nebraska 68504
Phone: +1-402-467-3576
Toll free: 800-447-3576 (U.S. and Canada)
[email protected]
LI-COR Distributor Network:
www.licor.com/envdistributors
Regional Offices
LI-COR Biosciences GmbH
Siemensstraße 25A
61352 Bad Homburg
Germany
Phone: +49 (0) 6172 17 17 771
[email protected]
LI-COR Biosciences UK Ltd.
St. John’s Innovation Centre
Cowley Road
Cambridge
CB4 0WS
United Kingdom
Phone: +44 (0) 1223 422102

Other LI-COR Measuring Instrument manuals

LI-COR LI-7810 User manual

LI-COR

LI-COR LI-7810 User manual

LI-COR LI-830 Guide

LI-COR

LI-COR LI-830 Guide

LI-COR 4300 User manual

LI-COR

LI-COR 4300 User manual

LI-COR LI-3000C Use and care manual

LI-COR

LI-COR LI-3000C Use and care manual

LI-COR LI-820 User manual

LI-COR

LI-COR LI-820 User manual

LI-COR LI-800 Guide

LI-COR

LI-COR LI-800 Guide

LI-COR LI-800 User manual

LI-COR

LI-COR LI-800 User manual

LI-COR TriSonica LI-560 User manual

LI-COR

LI-COR TriSonica LI-560 User manual

LI-COR LAI-2200 User manual

LI-COR

LI-COR LAI-2200 User manual

LI-COR LI-250A User manual

LI-COR

LI-COR LI-250A User manual

LI-COR LI-600 User manual

LI-COR

LI-COR LI-600 User manual

LI-COR LAI-2200 User manual

LI-COR

LI-COR LAI-2200 User manual

LI-COR LI-7700 User manual

LI-COR

LI-COR LI-7700 User manual

LI-COR LI-820 User manual

LI-COR

LI-COR LI-820 User manual

LI-COR LI-250 User manual

LI-COR

LI-COR LI-250 User manual

LI-COR LI-850 User manual

LI-COR

LI-COR LI-850 User manual

LI-COR LI-600 User manual

LI-COR

LI-COR LI-600 User manual

LI-COR LI-200R User manual

LI-COR

LI-COR LI-200R User manual

LI-COR LI-8100A User manual

LI-COR

LI-COR LI-8100A User manual

LI-COR LI-6800 User manual

LI-COR

LI-COR LI-6800 User manual

LI-COR LI-8100 User manual

LI-COR

LI-COR LI-8100 User manual

LI-COR LI-870 Guide

LI-COR

LI-COR LI-870 Guide

LI-COR LI-600 User manual

LI-COR

LI-COR LI-600 User manual

LI-COR LI-840 Guide

LI-COR

LI-COR LI-840 Guide

Popular Measuring Instrument manuals by other brands

cobas h 232 Operator's manual

cobas

cobas h 232 Operator's manual

sauter TVP-L instruction manual

sauter

sauter TVP-L instruction manual

ECOTEST MKS-05 TERRA operating manual

ECOTEST

ECOTEST MKS-05 TERRA operating manual

Motortech SparkView operating manual

Motortech

Motortech SparkView operating manual

AEMC 6526 quick start guide

AEMC

AEMC 6526 quick start guide

Extech Instruments 461893 user manual

Extech Instruments

Extech Instruments 461893 user manual

Circutor CVM-B100 instruction manual

Circutor

Circutor CVM-B100 instruction manual

Bosch Professional GLM 400 Series Original instructions

Bosch

Bosch Professional GLM 400 Series Original instructions

Pro PM-501X-VFL Operation guide

Pro

Pro PM-501X-VFL Operation guide

EEC EST-300 Series user manual

EEC

EEC EST-300 Series user manual

Milwaukee REDLITHIUM L4 3PL Operator's manual

Milwaukee

Milwaukee REDLITHIUM L4 3PL Operator's manual

bluelab Guardian Monitor Wi-Fi manual

bluelab

bluelab Guardian Monitor Wi-Fi manual

delta-mobrey 2468CA operating manual

delta-mobrey

delta-mobrey 2468CA operating manual

Keysight Technologies EPM Series Configuration guide

Keysight Technologies

Keysight Technologies EPM Series Configuration guide

Panametrics DigitalFlow GC868 Programming manual

Panametrics

Panametrics DigitalFlow GC868 Programming manual

GeoMax ZONE20 H user manual

GeoMax

GeoMax ZONE20 H user manual

Ametek Reichert AR5 user guide

Ametek

Ametek Reichert AR5 user guide

Siemens SEM3 Quick reference guide

Siemens

Siemens SEM3 Quick reference guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.