manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lightolier
  6. •
  7. Accessories
  8. •
  9. Lightolier Advent Lytespan 1 61XMCE User manual

Lightolier Advent Lytespan 1 61XMCE User manual

This manual suits for next models

11

Other Lightolier Accessories manuals

Lightolier 1004F13ESR User manual

Lightolier

Lightolier 1004F13ESR User manual

Lightolier Lytespan 6296 User manual

Lightolier

Lightolier Lytespan 6296 User manual

Lightolier Calculite C6CFL32 User manual

Lightolier

Lightolier Calculite C6CFL32 User manual

Lightolier Lytespan 24MHT45RF User manual

Lightolier

Lightolier Lytespan 24MHT45RF User manual

Lightolier Calculite GC User manual

Lightolier

Lightolier Calculite GC User manual

Lightolier Calculite RM-INC User manual

Lightolier

Lightolier Calculite RM-INC User manual

Lightolier Calculite C6P38A User manual

Lightolier

Lightolier Calculite C6P38A User manual

Lightolier Lytecaster 1113T User manual

Lightolier

Lightolier Lytecaster 1113T User manual

Lightolier Lytecaster 1001F Series Guide

Lightolier

Lightolier Lytecaster 1001F Series Guide

Lightolier Lytecaster 1095 User manual

Lightolier

Lightolier Lytecaster 1095 User manual

Lightolier 40829U User manual

Lightolier

Lightolier 40829U User manual

Lightolier C6TCAA User manual

Lightolier

Lightolier C6TCAA User manual

Lightolier 6099 User manual

Lightolier

Lightolier 6099 User manual

Lightolier Lytespan 8111 User manual

Lightolier

Lightolier Lytespan 8111 User manual

Lightolier LG Series User manual

Lightolier

Lightolier LG Series User manual

Lightolier Lytecaster 1045 User manual

Lightolier

Lightolier Lytecaster 1045 User manual

Lightolier MR-16 User manual

Lightolier

Lightolier MR-16 User manual

Lightolier 1005 User manual

Lightolier

Lightolier 1005 User manual

Lightolier Compact Fluorescent Frame-In Kit User manual

Lightolier

Lightolier Compact Fluorescent Frame-In Kit User manual

Lightolier 1004F26ESR User manual

Lightolier

Lightolier 1004F26ESR User manual

Lightolier mounting frame for insulated celing User manual

Lightolier

Lightolier mounting frame for insulated celing User manual

Lightolier D14 User manual

Lightolier

Lightolier D14 User manual

Lightolier ZYLINDER GLAS Guide

Lightolier

Lightolier ZYLINDER GLAS Guide

Lightolier SLOITED GRID CEILING CLIPS User manual

Lightolier

Lightolier SLOITED GRID CEILING CLIPS User manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0309
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Advent Lytespan® 1 and 2 Circuit Track 61XMCE
Page 1 of 3
2000mm
3000mm
4000mm
1.59mm
29.46mm
2
5
127.78mm
7
1
6
4
3
Plain Track
Features
1. Advent Lytespan Track: 6063-T5 Aluminum 1.8mm wall thickness.
2. Track Mounting Clips: 0.61mm Spring steel, in black or white; furnished with
track units.
3. Toggle Bolt & Screws: furnished with track units.
4. Conductor (3): 16A current carrying capacity.
5. Insulating Liner: 1.2mm wall, thermoplastic.
6. Neutral Conductor: on bead side of track.
7. Polarity Bead: identies the neutral conductor.
8. Live End: molded thermoplastic. Includes contacts for power supply leads.
9. Dead End Cover: molded thermoplastic.
10. Mini Coupler: connects track units mechanically and electrically.
Mechanical
Track units plug together and lock securely to prevent accidental separation. Track
units can be eld cut.
Finish
All painted nishes are baked enamel.
Mounting
Track may be surface mounted to ceilings or walls. The track may be stem mount-
ed. The track is not intended to be cable mounted. The track can also be recessed,
see Specication Sheet 7515.
Electrical
Two circuits individually controllable, rated 16 amps, at 220 - 240 volts 50 Hz
per track circuit (16 amps total for the two circuits), when supplied by a 220/240
volt, 50 Hz, single phase 3-wire branch circuit with a grounded neutral. The track
is polarized and continuously grounded throughout. Electrical conductors are
concealed in a insulating liner. Lytespan lighting units attach to the track at any
point and can be adjusted to operate on either track circuit. Not intended for use
with a power cord or a convenience receptacle adapter. Magnetic and electronic
transformers require different dimmer controls. Use the proper control device on
the track. Caution should be used when operating dimming controls on 3 wire
circuiting (the neutral conductor may overload). For additional information on dim-
ming, call 1-800-833-3664. All wiring must be in accordance with National and
Local Codes.
Labels
I.B.E.W.,CE
Finishes Plain Track
2m Catalog No. 3m Catalog No. 4m Catalog No.
Aluminum 612MALCE 613MALCE 614MALCE
Black 612MBKCE 613MBKCE 614MBKCE
White 612MWHCE 613MWHCE 614MWHCE
Lightolier is a Philips group brand
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0309
Advent Lytespan® 1 and 2 Circuit Track 61XMCE
Page 2 of 3
Grid Ceiling Mounting Clips
Square Edge Panels and 14.827mm-23.812mm
T-Bars Clip is supplied assembled. Mounts onto
T-Bars by rotating clips. Use two per 2m track,
three per 3m, and four per 4m track.
Set of 10
14.3 - 23.8mm
T-Runner
8 - 10.3mm
14.3 - 23.8mm
Square
Edge Panel
T-Runner
8mm
14.287mm
3.175 - 6.35mm
Toggle Bolt
Nylon Spacer
Screw
Track Mounting Clips
Furnished with track: 2 clips per 2m track,
3 clips per 3m and 4m track units. Attaches to
track at any point. Clip is nylon coated. White
clip supplied with white track, and aluminum,
black clip with black track. Spaces track from
ceiling.
Direct Mounting
Toggle bolts and nylon insulators are furnished
with Track, two per 2m track, three per 3m and
four per 4m track. Mount through existing holes
in track. Top of track sits flush to mounting
surface.
Regressed Edge Panels and 14.287mm-
23.812mm T-Bar Clip is supplied assembled.
Mounts easily onto T-Bars by rotating clips.
Use two per 2m track, three per 3m, and four
per 4m track.
Slotted Grid Ceilings such as Donn Fineline
and Chicago Metalic Ultraline 3500 and
3600.Use two per 2m track, three per 3m,
and four per 4m track.
Switches Track
240V
240V
Circuit 1
Neutral
Circuit2
BR
BL
BK
Switches Track
240V
Circuit 1
Neutral
Circuit2
BR
BL
Wiring Diagram
(3) wire two circuit 220/240, 50Hz single
phase with grounded neutral. Maximum total
track load (circuit 1 + circuit 2) = 16 amps.
220/240 50Hz single branch circuit, 16 amp
supply. Maximum load, 16 amps distributed
between track circuits.
6088 (9) Clips
Slotted Grid
Runner
6087 (9) Clips
6089 (9) Clips
56451WH Matte White
56451BK Matte Black
Not recommended for wall mounting.
Regressed
Edge Panel
Live End
Energizes Track from the beginning of a run. It
is included with Individual Track Units. Use
with plain track units.
6148ALCE Matte Aluminum
6148BKCE Matte Black
6148WHCE Matte White
In-Line Connector
Permits power feed between track units in a
straight run of track. The In-Line Connector is
polarized and pre-wired. KO permits direct
feed with electrical connector.
6154ALCE Matte Aluminum
6154BKCE Matte Black
6154WHCE Matte Aluminum
Mini-Coupler
Used to connect two pieces of track together
mechanically and electrically.
Power cannot
be fed to the Mini-Coupler.
6149ALCE Matte Aluminum
6149BKCE Matte Black
6149WHCE Matte White
114.3 mm
60.3 mm
Plastic Cover
Track
Recommended for wall
and ceiling mounting.
Track Mounting and Power Feed Systems
Lightolier is a Philips group brand
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0309
Advent Lytespan® 1 and 2 Circuit Track 61XMCE
Page 3 of 3
M20 (3/8" or 1/2")
Connector
Track
Power Extension
Connector
Beam
Jump
Track
Power Extension
Connector
Wall
Track
Power Extension
Connector
Track
Power Extension
Connector
M20 (3/8" or 1/2")
Connector Jump
Wall
(Conduit)
5-1/2"
3-11/32"
5-1/2"
11-3/4"
0-90
Ceiling to Wall
Wall
Inside
Corner
Wall
Outside
Corner
M20 (3/8" or 1/2")
Connector (by others)
Cast Plug
Live End Cover
Track Unit
Locknut
Live End
1/2" 14 Thread,
Integral with Live End
Live End
Track Unit
Variable Angle Connector
The Variable Angle Connector is pre-wired and
polarized. Connector will accept an M20 (3/8"
or 1/2") electrical fitting. (Use Locknut from
Cast Plug or 3/8" or 1/2" fitting.) Connector
flexes in all directions.
Direct Feed into Connectors
The Live End, “L”, ”T”, “X”, In-Line & Variable
Angle Connectors will accept an M20 (3/8" or
1/2") electrical fitting. Does not require a
separate power feed kit.
6151**CE1 External Right AL
6151**CE2 External Left AL
6151**CE3 Internal Right AL
6151**CE4 Internal Left AL
**Finishes: AL Matte Aluminum
BK Matte Black
WH Matte White
"T" Connector
The "T" connector is polarized and pre-wired.
Used to make "T" pattern with track. (See
fig. 1) 12 ga. copper jumper wires supplied to
make all necessary connections. KO permits
direct feed with electrical connector.
6153ALCE Matte Aluminum
6153BKCE Matte Black
6153WHCE Matte White
Power Extension Connector
Replaces Dead End Cover at end of track to
permit power continuity around structural
obstacles to another track section.
Accepts same power feed-in kits as Live End.
6146ALCE Matte Aluminum
6146BKCE Matte Black
6146WHCE Matte White
Over Beam or Through Beam
Through Wall or Column
"L" Connector
The "L" connector is polarized and pre-wired.
It may be rotated for right angle or left angle
turn. KO permits direct feed with electrical
connector.
6150ALCE Matte Aluminum
6150BKCE Matte Black
6150WHCE Matte White
"X" Connector
The "X" connector is not pre-wired or
polarized. Used to make "X" pattern with
track. 12ga. copper jumper wires supplied to
make all necessary connections. KO permits
direct feed with electrical connector.
6152ALCE Matte Aluminum
6152BKCE Matte Black
6152WHCE Matte White
M20 (3/8" or 1/2") Fitting, 3/8" recommended
(by others). Note: Use M20 locknut (not
shown) with M20 Fitting (by others). No
locknut needed with 3/8" or 1/2" fitting.
Track Mounting, Power Feed Systems and Mounting Patterns
6151XXCE1
External Right
6151XXCE2
External Left
Neutral
Track (Typ)
Neutral
6151XXCE4
Internal Left
6151XXCE3
Internal Right
Neutral
Neutral
Neutral
Neutral
View from Floor
Fig. 1