Specplus SPS2GFSVA26U or 217
Page 2 of 2 2' x 2' Recessed Fluorescent, Lens Frame Troffer
Static, 2 Lamp, T
Ord ring Information
Explanation of Catalog Number. Example: SPS2GFSVA26UUNVHI
Options/Acc ssori s
Sp cial L ns s: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average weight per
square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz. average weight per
square foot. Substitute S1 or S2 for VA (standard) =
Sky Acrylic Lens (see Sky Lens sell sheet for
further details).
Plast r Fram : Catalog Number: PF22.
Continuous Row Installation: For F type fixtures, half width flanges are required between
fixtures. Order Catalog Number: 2FC TRIM CSP (each joint).
Radio Int rf r nc Filt r:
To order one RIF per fixture; SUFFIX: R.
To order one RIF per ballast; SUFFIX: B.
Fusing: Internal fast-blow fusing. SUFFIX A.
Internal slow-blow fusing. SUFFIX C.
El ctrical Wiring Options: Consult factory.
Drywall Kit: Order Catalog Number: FK92X2. (Request Folio OA30-10 Rev. A).
Chicago Pl num: SUFFIX: C.
Sp cifications
P rformanc : In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance
80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To prevent glare the VCP shall
be not less than 40 either lengthwise or crosswise (at 100fc level) and the average brightness at 65°
shall not exceed 2629 candelas per square meter. To control veiling reflections, luminaire output inthe
30°-90° zone shall not be less than 67.4%.
Sp cifications (continu d)
Mat rials:Chassis parts are die-formed code gauge cold rolled steel. Housing
with side rails hemmed
over and housing ends turned-in for safe handling.
Finish:Chassis xt rior–black baked polyester enamel. Cavity–white baked polyester enamel
minimum 86% reflectance. Phosphate undercoating.
L ns s:VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the
panel edge, .095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12
with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz.
average weight per square foot.
El ctrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
Lab ls: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp.
Manage in accord with Disposal Laws. See: www.lamprecycle.org
Sp cplus:
Recessed
fluorescent
troffer
S
Static
2
Fixtur
Width
L ns Fram :
FS = Flat steel
frame.
RA= Regressed
aluminum
frame.
FA = Flat aluminum
frame.
L ns Shi lding
Typ :
VA=Virgin acrylic
(standard)
S1=Sky lens 1
S2=Sky lens 2
See options and
consult factory
2
Lamp
Quantity
Ballast Typ :
<20THD <10THD
1–2 Lamp Elec. T SO * HI*
LOL T Dimming PS –
*Instant Start Standard
Other dimming options. Consult factory.
NOTE:
For T8 UNV, you must use H
I
Ballast Code.
Options:
Add appropriate suffix
to catalog no., ie: (A)
Voltag :
120, 277 or
UNV=120-277
Lamp Typ /
Fixtur L ngth:
6U =
6"U Lamp T
17 =
T
(Nominal 24")
Not : For Lin ar
T5 Lamp option,
consult factory
SP Standard Specplus Plus
SX For NYC Code – Local 3 Manufactured
C iling Typ :
G= Grid
(lay-in T bar)
F= Flanged (over
lap) Z spline and
plaster frame
0.0 45.0 90.0 FLUX
0 1669 1669 1669
5 1659 1658 1661 158
15 1578 1593 1614 451
25 1431 1464 1502 675
35 1212 1249 1309 785
45 913 960 1068 750
55 572 611 673 551
65 318 302 342 319
75 160 146 192 178
85 58 62 78 70
90 000
Mod l No. SPS2GFSVA26U120SO
LER = FP - 58.6 IW - 56.3 BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = 4.10
Report Number: G00035
Catalog Number: SPS2GFSVA26U120SO
Lamps: (2) U6T8
Luminaire: 2' x 2' SpecPlus with regressed
aluminum door frame and extruded
virgin acrylic shielding .095" nominal
thickness (similar to pattern 12).
Ballast: REL-2P32-SC
Report is based on 2750 Lumens per lamp.
Efficiency: 71.6%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 21.875 21.875
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 4164. 4410. 4906.
55 3239. 3460. 3811.
65 2444. 2321. 2629.
75 2008. 1832. 2410.
85 2162. 2311. 2907.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 79 75 73 71 69 67 68 66 65
02 72 67 62 63 59 56 61 58 55
03 66 59 54 56 52 48 54 51 47
04 61 53 47 50 46 42 49 45 41
05 56 48 42 45 40 37 44 40 36
06 52 43 37 41 36 32 40 36 32
07 49 39 33 38 33 29 37 32 29
08 45 36 30 35 30 26 34 29 26
09 42 33 28 32 27 24 31 27 23
10 40 31 25 30 25 21 29 25 21
ZONE LUMENS % LAMP % FIXT
00-030 1283 23.3 32.6
00-040 2069 37.6 52.6
00-060 3369 61.3 85.6
00-090 3936 71.6 100.0
90-180 0000 0.0 000.0
00-180 3936 71.6 100.0
ZONAL LUMEN SUMMARY
Job Information Type:
For Factory Technical Information: (97 ) 657-7600 • Fax (97 ) 65 -0595 02/10
631 Airport Road, Fall River, MA 02720 • (50 ) 679- 131 • Fax (50 ) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group S ction 1A/Folio E60-20 R v. B
Photom try Sky L ns Options
S1 S2