manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lightolier
  6. •
  7. Light Fixture
  8. •
  9. Lightolier 1004ICVN Instructions for use

Lightolier 1004ICVN Instructions for use

This manual suits for next models

1

Other Lightolier Light Fixture manuals

Lightolier 40600H1 Guide

Lightolier

Lightolier 40600H1 Guide

Lightolier Lytespan 8217WH User manual

Lightolier

Lightolier Lytespan 8217WH User manual

Lightolier Lytespan 8605WH User manual

Lightolier

Lightolier Lytespan 8605WH User manual

Lightolier Calculite C6T6VN User manual

Lightolier

Lightolier Calculite C6T6VN User manual

Lightolier D13 User manual

Lightolier

Lightolier D13 User manual

Lightolier LYEDROP FIXTURE Guide

Lightolier

Lightolier LYEDROP FIXTURE Guide

Lightolier Lytespan 9176 User manual

Lightolier

Lightolier Lytespan 9176 User manual

Lightolier Calculite 7782 User manual

Lightolier

Lightolier Calculite 7782 User manual

Lightolier VTS2GPK332 User manual

Lightolier

Lightolier VTS2GPK332 User manual

Lightolier ALETTA AL2T8 User manual

Lightolier

Lightolier ALETTA AL2T8 User manual

Lightolier Lytecaster 2002P1 User manual

Lightolier

Lightolier Lytecaster 2002P1 User manual

Lightolier Lytespan 8103 User manual

Lightolier

Lightolier Lytespan 8103 User manual

Lightolier PristineHW Series User manual

Lightolier

Lightolier PristineHW Series User manual

Lightolier Lytecaster 377X User manual

Lightolier

Lightolier Lytecaster 377X User manual

Lightolier Lytecaster 1022 User manual

Lightolier

Lightolier Lytecaster 1022 User manual

Lightolier Calculite ProSpec PA1H3870 User manual

Lightolier

Lightolier Calculite ProSpec PA1H3870 User manual

Lightolier 1101FDM User manual

Lightolier

Lightolier 1101FDM User manual

Lightolier Calculite AF2PF User manual

Lightolier

Lightolier Calculite AF2PF User manual

Lightolier 16FR2X6 User manual

Lightolier

Lightolier 16FR2X6 User manual

Lightolier Lytecel LIS6G20LW132 User manual

Lightolier

Lightolier Lytecel LIS6G20LW132 User manual

Lightolier VR PARABOLIC VRA2G16LS26U User manual

Lightolier

Lightolier VR PARABOLIC VRA2G16LS26U User manual

Lightolier Lytespan 6276B User manual

Lightolier

Lightolier Lytespan 6276B User manual

Lightolier Decorative Arco 4833 User manual

Lightolier

Lightolier Decorative Arco 4833 User manual

Lightolier Lytespan 9175N User manual

Lightolier

Lightolier Lytespan 9175N User manual

Popular Light Fixture manuals by other brands

Veko Magnus manual

Veko

Veko Magnus manual

Cooper Lighting Halo L10538 specification

Cooper Lighting

Cooper Lighting Halo L10538 specification

Emos CLASSIC ZY1431T manual

Emos

Emos CLASSIC ZY1431T manual

Westinghouse Outdoor Lighting Fixture owner's manual

Westinghouse

Westinghouse Outdoor Lighting Fixture owner's manual

Hedler C 12 silent Operation manual

Hedler

Hedler C 12 silent Operation manual

Blizzard Lighting Puck: CSI manual 

Blizzard Lighting

Blizzard Lighting Puck: CSI manual 

Energetic Lighting ELYSL-5004 Series installation instructions

Energetic Lighting

Energetic Lighting ELYSL-5004 Series installation instructions

Lightmaxx Shaft 5R user manual

Lightmaxx

Lightmaxx Shaft 5R user manual

Triarch 31083 Assembly instructions

Triarch

Triarch 31083 Assembly instructions

Philips 32614 Series user manual

Philips

Philips 32614 Series user manual

IKEA TIVED Assembly instructions

IKEA

IKEA TIVED Assembly instructions

Chauvet Professional ROGUE R1 BEAM WASH user manual

Chauvet Professional

Chauvet Professional ROGUE R1 BEAM WASH user manual

Martin MAC 250 Krypton user manual

Martin

Martin MAC 250 Krypton user manual

Cooper Lighting Halo L3232E Specification sheet

Cooper Lighting

Cooper Lighting Halo L3232E Specification sheet

Stageline ODW-2410RGBW instruction manual

Stageline

Stageline ODW-2410RGBW instruction manual

ArtFox Beam 15R extreme manual

ArtFox

ArtFox Beam 15R extreme manual

GLG multispot 330 user manual

GLG

GLG multispot 330 user manual

Home Accents Holiday TY052-1924-1 Assembly instructions

Home Accents Holiday

Home Accents Holiday TY052-1924-1 Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTRUCTION SHEET NO.
IS:1004ICV
B1204 Page 1 of 4
INSTALLATION PROCEDURE FOR LOW VOLTAGE
INSULATED CEILING FRAME-IN-KIT 1004ICV, 1004ICVN
1. FRAME-IN (Fig. A)
Locate fixture along joist and line up bottom edge of HINGED
MOUNTING BAR with the bottom of joist and fasten in place.
Fig. A
Frame-In
Fig. B
Wire-In
Fig. C
Swing-Up
Fig. D
Close-In
Fig. E
Snap-On
Fig. F
Push-Up
For suspended ceilings:
•Rotate HINGED BAR ENDS to position shown
and fully extend bars.
•Crimp bottom of edge of CHANNEL to prevent
rotation of HINGED BAR ENDS.
•Bend NON-HINGED end of mounting bar at
featured hole location and extend out.
•Position notched area of MOUNTING BARS onto
T-BAR and lock by bending TAB underneath
T-BAR BEAD as shown.
•For suspended ceiling, make certain that bottom
of Mounting Frame is no higher than 1” above
ceiling line.
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
®
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720
NEW CONSTRUCTION
NOTE: I.C. Frame-in Kit may be used in direct contact with insulation.
WARNING: USE ONLY WITH LIGHTOLIER REFLECTOR TRIMS MARKED WITH I.C. LAMPING INFORMATION. USE OF OTHER
MANUFACTURERS’ TRIMS VOIDS THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD
HINGED MOUNTING BAR
5 5/8”
6”
CENTER LINE OF
APERTURE OPENING
Fig. G
Note: Integral nail version available
TAB
T-BAR
HINGED BAR ENDS
CHANNEL
TAB
BEND AT TAB
BEND AT HOLE
FOR JOIST SPACING LESS THAN 16” ON CENTER (TO 12” ON CENTER):
•MOUNTING BAR CHANNELS can be shortened and used as
nailing legs in tight spaces. Simply remove INNER BAR from
holed CHANNEL, bend CHANNEL at appropriate point and
use extra screw to secure it to the joist. (Fig. G)
INSTRUCTION SHEET NO.
IS:1004ICV
B1204 Page 3 of 4
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
®
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720
8. LAMPING (Fig. H)
1. Make sure that power is OFF when lamping or relamping.
Remove LAMP RING from TRIM by pulling straight down.
2. Remove LAMP SHIELD from LAMP RING.
3. Place LAMP SHIELD on back of LAMP (MR-16) and insert both
between LAMP SPRINGS until face of lamp sits firmly on GLASS LAMP
GUARD (Fig. J).
WARNING: RISK OF FIRE. LAMP SHIELD MUST BE INSTALLED.
4. Attach SOCKET to bi-pin prongs on LAMP.
5. Insert LAMP RING with LAMP SHIELD, LAMP and GLASS LAMP
GUARD back into TRIM.
FEMALE CONNECTORS
(ATTACHED TO FIXTURE WIRES)
MALE CONNECTORS
(ATTACHED TO SOCKET WIRES)
MR16 SOCKET
LAMP SPRING
Fig. H
LAMP SHIELD
INSULATING SLEEVING
GLASS LAMP GUARD
SOCKET
LAMP RING
Fig. J
NOTE: 1. LOW VOLTAGE FIXTURES should be
dimmed only with special dimmers intended
specifically for that purpose. Use Lightolier
Lytemode, Scenist, Crescendo VA, Neptune VA,
Precision VA, Easyset VA, Sunrise VA, Radiant
VA or equivalent products by others or variable
autotransformers or electronic dimmers
intended for use with low voltage fixtures.
2. Low voltage fixtures may produce audible
sound which may be objectionable in acousti-
cally critical areas.
LAMP
WARNING: 1. LAMP MANUFACTURERS REQUIRE THE GLASS LAMPGUARD BE IN PLACE BEFORE ENERGIZING LAMP, AND THAT GREAT
CARE MUST BE TAKEN THAT LAMP IS FULLY COOLED BEFORE RELAMPING. AVOID FINGER MARKS ON INSIDE OF LAMP FOR THEY MAY
CAUSE SHORT LAMP LIFE AND POSSIBLE BREAKAGE. 2. USE ONLY REFLECTOR TRIMS
PROVIDED BY LIGHTOLIER INC. USE OF OTHER
MANUFACTURER'S REFLECTOR TRIMS VOIDS THE UNDERWRITERS LABORATORIES
LISTING AND COULD CONSTITUTE A FIRE HAZARD.
9. TRANSFORMER REPLACEMENT (Fig. K)
1. Make sure power is off.
2. Remove REFLECTOR TRIM from ceiling.
3. Remove SCREW and lift TRANSFORMER off bracket.
4. Remove J-BOX COVER by removing wing nut.
5. Unsplice primary leads in J-BOX.
6. Remove primary leads from J-BOX cover and clip attached to side
of housing.
7. Cut secondary (red) leads 6" to 8" from TRANSFORMER and dis-
card faulty transformer.
8. Install new TRANSFORMER:
(WARNING: RISK OF FIRE. Transformer contains fixture thermal
protector. Replace as shown and described below. Use only
replacement transformer obtained from LIGHTOLIER.)
a. Splice secondary (red) leads to socket leads.
b. Attach TRANSFORMER to BRACKET with SCREW, making
sure that the side of transformer that has the wire leads is
facing the housing wall (Fig.L)
c. Put primary leads through clip and bushing in the J-BOX
COVER.
e. Wire primary leads to supply leads.
f. Replace J-BOX COVER.
g. Install REFLECTOR TRIM.
Fig. K
ROTO CLIPS
JUNCTION BOX
MAX. OF (6) #12 AWG BRANCH
CIRCUIT CONDUCTORS SUITABLE
FOR AT LEAST 90° C PERMITTED
IN JUNCTION BOX.
TRANSFORMER
PRIMARY: 120V, 60HZ
SECONDARY: 110V, 50W LOAD
SCREW
SECONDARY
(RED) LEADS
PRIMARY
LEADS
CLIP
INSTRUCTION SHEET NO.
IS:1004ICV
B1204 Page 4 of 4
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
®
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720
APERTURE
HOLE
TRANSFORMER
WIRE LEADS
HOUSING
WALL
Fig. L