manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lightolier
  6. •
  7. Light Fixture
  8. •
  9. Lightolier Coffaire II CFA2GPF217 User manual

Lightolier Coffaire II CFA2GPF217 User manual

Mounting Metho s Dimensions
Features
• Direct/indirect lamp shield appearance with soft contoured interior.
• Perforated mesh lamp shield with white acrylic overlay.
• Contoured body and ends.
• Air supply and return.
• Air return slots located above lamp shield.
• Air return models meet UL 159 , Paragraph 9.2.2.5 requirements.
• 61.7% efficient (2 lamp T ).
• 55.9% efficient (3 lamp T ).
• Spacing to mounting ratio 1.4 (2 lamp).
• Spacing to mounting ratio 1.3 (3 lamp).
• Only 5" deep.
• Tension screws secure ends to body.
• Perforated lamp shield hinges from either side.
• Can be continuous row mounted.
• Built-in earthquake clips.
• Ballast accessible from room side.
• Optional supply air slot cover.
• Meets NYC Code.
• Construction to meet Chicago Plenum requirements is available.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
05/07
Coffaire II Recessed Fluorescent CFA2GPF217 or 317
Page 1 of 2 Direct/Indirect – 2' x 2' with Perforated Basket
Air Supply and Return, 2 Lamp or 3 Lamp, T8
24" (610mm)
5"
(127mm)
2-1/2"
(64mm)
2" x 2-1/2" Access Plate
with 7/ " dia. K.O.
24" (610mm)
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 6 7-7600 • Fax (978) 6 8-0 9
631 Airport Road, Fall River, MA 02720 • ( 08) 679-8131 • Fax ( 08) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company Section 5/Folio M15-36
lamp shield hinges either side
exposed t-grid ceiling
Exposed T-bar
by others
1-1/2"
max.
Acoustical
material
by others
15/16"
24"
built-in earthquake clips
Coffaire II Recessed Fluorescent CFA2GPF217 or 317
Page 2 of 2 Direct/Indirect – 2' x 2' with Perforated Basket
Air Supply and Return, 2 Lamp or 3 Lamp, T8
Job Information Type:
Or ering Information
Explanation of Catalog Number. Example: CFA2GPF217120SO
Options/Accessories
Optional supply air slot cover: Order Catalog Number: CACS-2
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Drywall Kit: Order Catalog Number: FK92X2.
Electrical Wiring Options: Consult factory.
Chicago Plenum: SUFFIX: C.
Dust Shiel : See Folio Number: OA50-20
Specifications
Performance: In an installation of 2 lamp 40W luminaires in a room cavity
ratio of 1, with reflectance 0% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .64. To reduce glare the average brightness at 65° shall not exceed
1 15 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 73.2%.
Materials: Chassis parts are die-formed code gauge steel.
Lamp Shiel : 22 gauge steel perforated mesh lamp shield with white
acrylic overlay.
Specifications (continue )
Finish: Chassis exterior – soft white post painted polyester powder. Cavity –
soft white post painted polyester powder. Reflector – soft white post painted
polyester powder, minimum % reflectance. Rust preventive undercoating.
Lamp Shiel –white.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp
locations.
Labels: I.B.E.W./UL and ULc Listed.
Options:
Add appropriate
suffix to catalog
no., ie: (GLR)
Coffaire II:
Direct/
In irect:
Recessed
with Perforated
Mesh Shield
A
Bo y Style:
A= Air Supply
and Return
2
Fixture
Wi th
G
Ceiling Type:
Standard Grid
P
Perforate
Lamp
Shiel
17
Lamp:
(By Others)
17=T8
(Nominal 24")
F
Flat
White
Reflector
Lamp
Quantity
2=2 Lamp
3=3 Lamp
Ballast Type:
<20THD <10THD
1 or 2 Lamp Elec. T8 SO * HI*†
1-3 Lamp Elec. T8 O3 * H3 *†
LOL Dimming T8 PS*–
*Instant Start Standard
Other dimming options. Consult factory.
NOTE: For T8 UNV, you must use H
I
,H3, Ballast Code.
Mo el No. CFA2GPF217120SO
LER = FP - 50.2 IW - 30.0 BF - 0.93
Comparative yearly lighting energy cost per
1000 lumens = $4.7
Report Number: G200424
Catalog Number: CFA2GPF217120SO
Lamps: F017/41K
Luminaire: Coffaire 2'x2' with perforated
basket
Ballast: Triad C240SI120
Report is based on 1350 Lumens per lamp.
Efficiency: 61.7%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.4
Shielding Angles: 55 65
Plane: 0-Deg 90-Deg
Luminous Length: 22.920 22.920
CANDELA DISTRIBUTION0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1443. 166 . 1 56.
55 1301. 1656. 192 .
65 10 9. 1605. 1 15.
75 9. 1037. 1219.
5 50 . 541. 575.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 67 64 62 60 5 57 5 56 55
02 61 56 52 53 49 47 51 4 46
03 56 49 44 46 42 39 45 41 3
04 51 43 3 41 37 33 40 36 33
05 47 39 33 37 32 29 35 31 2
06 43 35 29 33 2 25 32 2 25
07 40 32 26 30 25 22 29 25 22
037 29 23 27 23 20 27 23 19
09 35 26 21 25 21 1 25 20 1
10 32 24 19 23 19 16 23 19 16
ZONE LUMENS % LAMP % FIXT
00-030 446 16.5 26.
00-040 736 27.3 44.2
00-060 1327 49.1 79.7
00-090 1665 61.7 100.0
90-1 0 0000 0.0 000.0
00-1 0 1665 61.7 100.0
ZONAL LUMEN SUMMARY
Mo el No. CFA2GPF317120O3
LER = FP - 4 .7 IW - 46.5 BF - 1.00
Comparative yearly lighting energy cost per
1000 lumens = $0.00
Report Number: G2004249
Catalog Number: CFA2GPF317120O3
Lamps: F017/41K
Luminaire: Coffaire with perforated
basket
Ballast: Triad B332I120
Report is based on 1350 Lumens per lamp.
Efficiency: 55.9%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 55 65
Plane: 0-Deg 90-Deg
Luminous Length: 22.920 22.920
0.0 45.0 90.0 FLUX
0 00 00 00
5 794 796 79 76
15 754 766 7 0 217
25 6 4 712 741 329
35 591 63 6 2 399
45 476 544 600 417
55 346 431 493 3 0
65 20 300 33 2 3
75 103 133 147 137
5 19 22 23 27
90 000
CANDELA DISTRIBUTION0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 19 5. 2269. 2503.
55 1779. 2216. 2535.
65 1452. 2094. 2359.
75 1174. 1516. 1675.
5 643. 745. 77 .
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 61 5 56 55 53 51 53 51 50
02 56 51 47 4 45 42 46 44 42
03 51 45 40 42 39 36 41 3 35
04 46 40 35 37 33 30 36 33 30
05 43 35 30 34 29 26 32 29 23
06 39 32 27 30 26 23 29 26 23
07 36 29 24 27 23 20 27 23 20
034 26 22 25 21 1 24 21 1
09 32 24 20 23 19 16 23 19 16
10 30 22 1 21 17 15 21 17 15
ZONE LUMENS % LAMP % FIXT
00-030 621 15.3 27.4
00-040 1020 25.2 45.1
00-060 1 17 44.9 0.3
00-090 2264 55.9 100.0
90-1 0 000000.0 000.0
00-1 0 2264 55.9 100.0
ZONAL LUMEN SUMMARY
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 6 7-7600 • Fax (978) 6 8-0 9
631 Airport Road, Fall River, MA 02720 • ( 08) 679-8131 • Fax ( 08) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company Section 5/Folio M15-36
Voltage:
120, 277 or
UNV=120-277
0.0 45.0 90.0 FLUX
0 572 572 572
5 569 570 570 54
15 541 550 560 155
25 492 515 537 237
35 426 465 500 290
45 346 400 445 307
55 253 322 375 2 3
65 156 230 260 215
75 7 91 107 104
5 15 16 17 20
90 000
CF Standard Coffaire II
CN For NYC Code –Local 3 Manufactured

Other Lightolier Light Fixture manuals

Lightolier Lytecaster 317X User manual

Lightolier

Lightolier Lytecaster 317X User manual

Lightolier L56LED User manual

Lightolier

Lightolier L56LED User manual

Lightolier Calculite C4P20L User manual

Lightolier

Lightolier Calculite C4P20L User manual

Lightolier Lytecaster 1004SICR User manual

Lightolier

Lightolier Lytecaster 1004SICR User manual

Lightolier QVH1GPFOS2FT User manual

Lightolier

Lightolier QVH1GPFOS2FT User manual

Lightolier 4K28 User manual

Lightolier

Lightolier 4K28 User manual

Lightolier MD*COFFER MDCG2BX User manual

Lightolier

Lightolier MD*COFFER MDCG2BX User manual

Lightolier Wal-Lyter WLRN244120SB User manual

Lightolier

Lightolier Wal-Lyter WLRN244120SB User manual

Lightolier Lytespan 8735 User manual

Lightolier

Lightolier Lytespan 8735 User manual

Lightolier 1000AICM User manual

Lightolier

Lightolier 1000AICM User manual

Lightolier H9S2GLR254 User manual

Lightolier

Lightolier H9S2GLR254 User manual

Lightolier Lytespan 8330 User manual

Lightolier

Lightolier Lytespan 8330 User manual

Lightolier SL403A User manual

Lightolier

Lightolier SL403A User manual

Lightolier Lytecaster 1035 User manual

Lightolier

Lightolier Lytecaster 1035 User manual

Lightolier Lytecaster 1052LV User manual

Lightolier

Lightolier Lytecaster 1052LV User manual

Lightolier Lytecaster 384X User manual

Lightolier

Lightolier Lytecaster 384X User manual

Lightolier ProSpec Track Lighting User manual

Lightolier

Lightolier ProSpec Track Lighting User manual

Lightolier Calculite C7E17VW User manual

Lightolier

Lightolier Calculite C7E17VW User manual

Lightolier Lytespan 8103 User manual

Lightolier

Lightolier Lytespan 8103 User manual

Lightolier Calculite ProSpec PA2H3039 User manual

Lightolier

Lightolier Calculite ProSpec PA2H3039 User manual

Lightolier Decorative Arco 4833 User manual

Lightolier

Lightolier Decorative Arco 4833 User manual

Lightolier ProSpec 37113 User manual

Lightolier

Lightolier ProSpec 37113 User manual

Lightolier Lytespan 8119 User manual

Lightolier

Lightolier Lytespan 8119 User manual

Lightolier CDS2GPF214 User manual

Lightolier

Lightolier CDS2GPF214 User manual

Popular Light Fixture manuals by other brands

Emos ZV1111 manual

Emos

Emos ZV1111 manual

Cooper Lighting Electronic Metal Halide MA6AR Specifications

Cooper Lighting

Cooper Lighting Electronic Metal Halide MA6AR Specifications

Soundoff Signal GHOST EGHSTE5 B Series quick start guide

Soundoff Signal

Soundoff Signal GHOST EGHSTE5 B Series quick start guide

Safety 1st Under Crib Smart Light quick start guide

Safety 1st

Safety 1st Under Crib Smart Light quick start guide

EuroLite TMH-155 Moving-Head user manual

EuroLite

EuroLite TMH-155 Moving-Head user manual

Cooper Lighting Metalux HBO SERIES Specifications

Cooper Lighting

Cooper Lighting Metalux HBO SERIES Specifications

Beamz Panther 25 Led Spot instruction manual

Beamz

Beamz Panther 25 Led Spot instruction manual

Lighting Science HEALTHE Cleanse Set up and operation guide

Lighting Science

Lighting Science HEALTHE Cleanse Set up and operation guide

Lumiere Coronado 806 Specifications

Lumiere

Lumiere Coronado 806 Specifications

Wagan FRED Light 2639 user manual

Wagan

Wagan FRED Light 2639 user manual

Eaton All-Pro WPS2040M instruction manual

Eaton

Eaton All-Pro WPS2040M instruction manual

Triarch Indoor Lighting 29771 instructions

Triarch

Triarch Indoor Lighting 29771 instructions

TECshow BEAMER 7R user manual

TECshow

TECshow BEAMER 7R user manual

Energetic Lighting E1HBA Series installation instructions

Energetic Lighting

Energetic Lighting E1HBA Series installation instructions

ADJ StarTec Series user manual

ADJ

ADJ StarTec Series user manual

Portfolio DUALBRITE 4291 user manual

Portfolio

Portfolio DUALBRITE 4291 user manual

Acuity Brands Lithonia Lighting D-Series Wall installation instructions

Acuity Brands

Acuity Brands Lithonia Lighting D-Series Wall installation instructions

Lumiere Coronado 812 Specifications

Lumiere

Lumiere Coronado 812 Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.