
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK91X4.
Electrical Wiring Options: Consult factory.
Specifications
Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1,
with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .55.
To reduce glare the average brightness at 65° shall not exceed 2454 candelas per
square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall
not be less than 70.4%.
Materials: Chassis parts are die-formed 20 gauge steel.
Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.
Finish: Chassis exterior – baked white polyester enamel. Cavity – baked flat white
polyester enamel. Reflector – baked flat white polyester enamel, minimum 86%
Ordering Information
Explanation of Catalog Number. Example: CFH1GPF232120SOGLR
Specifications (continued)
reflectance. Rust preventative undercoating. Lamp Shield – baked flat white polyester
enamel.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is
within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal
Laws. See: www.lamprecycle.org
Options:
Add appropriate suffix
to catalog no., ie: (A)
Coffaire:
Direct/
Indirect:
Recessed
with Perforated
Mesh Shield
Body Style:
H= Air Return
S= Static
1
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
P
Perforated
Lamp
Shield
Lamp:
(By Others)
32 = T
28 = T5
54 = T5HO
(Nominal 24")
F
White
Reflector
Lamp
Quantity
1= 1 Lamp
2= 2 Lamp Ballast Type:
<20THD <10THD
1 & 2 Lamp Elec. T SO* HI*
1-2 Lamp 2 W Elec. T5 –P
I
1-2 Lamp 2 W Elec. T5 –PG
1-2 Lamp 54W Elec. T5 –PG
Linear T5 Instant Start WA
less than 10THD,
57.5 Input Watts,
0.93 Ballast Factor
LOL Dimming T PS –
*Instant Start Standard
†Instant Start (120V or 277V only)
††Program Rapid Start (UNV only)
Other dimming options. Consult factory.
NOTE:
For T8 UNV, you must use H
I
Ballast Code.
0.0 45.0 90.0 FLUX
0 1157 1157 1157
5 1147 1148 1153 109
15 1096 1095 1100 309
25 1004 998 995 460
35 877 858 854 539
45 720 692 696 540
55 535 514 511 464
65 343 330 341 333
75 172 168 165 175
85 27 33 34 39
90 000
Coffaire II R
ecessed Fluorescent CFH1GPF
Page 2 of 2 Direct/Indirect – 1' x 4' with Perforated Basket
Air Return/Static, 1 or 2 Lamp T or T5
Model No. CFH1GPF232120SO
LER = FP - 38.0 IW - 67.7 BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = 6.32
Report Number: G2004063
Catalog Number: CFH1GPF232120SO
Lamps: F32/T8 TL841
Luminaire: CFH 1' x 4' with perforated basket
Ballast: Triad B332I120
Report is based on 2850 Lumens per lamp.
Efficiancy: 52.1%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.2
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 46.920 10.920
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3079. 2959. 2977.
55 2821. 2710. 2694.
65 2454. 2361. 2440.
75 2010. 1963. 1928.
85 0937. 1145. 1180.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 57 55 52 51 50 48 49 48 47
02 52 48 44 45 42 40 43 41 39
03 47 42 38 40 36 34 38 36 33
04 44 37 33 35 32 29 34 31 29
05 40 34 29 32 28 25 31 27 25
06 37 30 26 29 25 22 28 25 22
07 34 27 23 26 22 20 26 22 19
08 32 25 21 24 20 18 23 20 17
09 30 23 19 22 18 16 22 18 16
10 28 21 17 21 17 14 20 17 14
ZONE LUMENS % LAMP % FIXT
00-030 0879 15.4 29.6
00-040 1418 24.9 47.8
00-060 2421 42.5 81.6
00-090 2968 52.1 100.0
90-180 0000 0.0 000.0
00-180 2968 52.1 100.0
ZONAL LUMEN SUMMARY
Section 5/Folio M15-20 Rev. A
Voltage:
120, 277 or
UNV=120-277
0.0 45.0 90.0 FLUX
0 1076 1076 1076
5 1065 1069 1075 102
15 1018 1025 1031 289
25 935 939 944 433
35 820 819 834 516
45 677 680 699 528
55 510 523 513 460
65 333 335 346 336
75 173 178 179 185
85 31 44 46 49
90 000
Model No. CFH1GPF228120WA
LER = FP - 47.5 IW - 57 BF - 0.93
Comparative yearly lighting energy cost per
1000 lumens = 5.05
Report Number: G2005196
Catalog Number: CFH1GPF228120WA
Lamps: FP28/835/PM ECO
Luminaire: CFH 1' x 4' with perforated basket
Ballast: WA Energy Saver System
Report is based on 2600 Lumens per lamp.
Efficiancy: 55.7%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.2
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 46.920 10.920
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2895. 2908. 2989.
55 2689. 2757. 2705.
65 2383. 2397. 2476.
75 2021. 2080. 2091.
85 01076. 1527. 1596.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 61 58 56 54 53 51 52 51 50
02 55 51 47 48 45 42 46 44 41
03 50 45 40 42 39 36 41 38 35
04 46 40 35 37 34 30 36 33 30
05 43 35 30 34 30 26 33 29 26
06 39 32 27 30 26 23 29 26 23
07 36 29 24 28 24 21 27 23 20
08 34 26 22 25 21 18 25 21 18
09 32 24 20 23 19 17 23 19 16
10 30 22 18 22 18 15 21 17 15
ZONE LUMENS % LAMP % FIXT
00-030 0824 15.9 28.4
00-040 1340 25.8 46.2
00-060 2328 44.8 80.3
00-090 2898 55.7 100.0
90-180 0000 0.0 000.0
00-180 2898 55.7 100.0
ZONAL LUMEN SUMMARY
Job Information Type:
For Factory Technical Information: (97 ) 657-7600 • Fax (97 ) 65 -0595 0 /10
631 Airport Road, Fall River, MA 02720 • (50 ) 679- 131 • Fax (50 ) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group Section 5/Folio M15-20 Rev. B
CF Standard Coffaire II
CY For NYC Code – I.B.E.W. Manufactured