Features
• 48.6% efficient (2 lamp) semi-specular louver.
• 51.6% efficient (2 lamp) specular louver.
• 1.3 spacing mounting ratio.
• Semi-specular or specular, low iridescence, pre-anodized
aluminum louver.
• Vertical grain on cross blades eliminates reflected lamp image.
• Spring loaded latches (self centering).
• Louver has protective dust guard.
• Only 5-1/2" deep body.
• Black housing exterior for cooler ballast operating temperature.
• UL-Listed twin knockout access plate.
• Can be mounted in continuous rows.
• 2 hold-down clips standard.
• Compatible with Armstrong TECHZONE®ceiling systems.
• Meets NYC Code requirements
• Construction to meet Chicago Plenum Code is available.
• Optional DALI ballast accepts digital dimming commands from
computers, scene controllers and automatic control devices.
Mounting Methods Dimensions
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte company www.lightolier.com
Technical In ormation: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details o design, materials and inish.
© 2007 a Genlyte company Section 2/Folio G07-36
3/07
Lytecel Recessed Fluorescent LIS6G20LW232
Page 1 o 2 6" wide x 48", 20 Cell (1 Row) Parabolic Louver,
Air Return/Static, 2 Lamp T8, IES RP1 For VDT Areas
Gexposed T-grid ceiling.
6"
15/16"
or
9/16"
Texposed slot T-grid ceiling.
2" max.
9/16"
2" max.
hold-down clips (1 at each end)
5-1/2"
(139mm)
4-1/4" (108mm)
6" (162mm)
6"
A/D Tegular grid ceiling
2" max.
6"
15/16"
or
9/16"
Shown in Armstrong TECH ceiling.
48"
(1200mm)
48"
(1200mm)
Joint of Two Units
2" x 2-1/2" Access Plate
with (2) 7/8" K.O.s
7-3/8"
(187mm)
48"
(1220mm)
39-1/4" (997mm)
Air Return Slots
(LIA only)
1-3/4" (44mm)
Lytecel Recessed Fluorescent LIS6G20LW232
Page 2 o 2 6" wide x 48", 20 Cell (1 Row) Parabolic Louver,
Air Return/Static, 2 Lamp T8, IES RP1 For VDT Areas
Lightolier a Genlyte company www.lightolier.com
Technical In ormation: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details o design, materials and inish.
© 2007 a Genlyte company Section 2/Folio G07-36
Job Information Type:
Ordering Information
Explanation o Catalog Number. Example: LIS6G20LW232120SO
Options/Accessories
Access Plate: Top Wiring access plate is shipped with fixture
as standard. When
access plates are required in advance for wiring convenience, specify separately.
Order Catalog Number: ACP5 CSP.
Electrical/Wiring Options: Consult factory.
EM Pack or Dimming Ballast: Consult factory.
Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Chicago Plenum: Suffix: CP.
Specifications
Performance: In an installation of 2 lamp 32W semi-specular luminaires in a
room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U.
shall not be less than .53 with a spacing to mounting ratio of 1.3 perpendicular
to the lamps. To meet IES RP-1 for VDT areas the VCP (visual comfort probabili-
ty) shall not be less than 91 either crosswise or lengthwise and the candela
value between 55 and 90 in the 0 to 90 planes shall not exceed 4631.
Candelas at Nadir (0 ) not to exceed 1234.
Air Handling-(LIA) side air passages for air return.
Materials: Chassis parts are die-formed cold rolled steel.
Louver: Pre-anodized aluminum (Coilzak®or equal).
Specifications (continued)
Finish: Louver—specular or semi-specular low iridescence pre-anodized
reflector sheet. Reflector: White baked polyester enamel reflector. Chassis
exterior—black baked polyester enamel.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90 .
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with
Disposal Laws. See: www.lamprecycle.org
LI:
Lytecel 6"
6
Fixture
Width
20
Number of
Cells:
1 row o
20 cells
Louver Finish:
L=Low
Iridescence
Semi-
specular
P=Low
Iridescence
S
pecular
W2
Lamp
Quantity:
(By others)
2=2 Lamp
32
Lamp Fixture
Length:
32=T8
(Nominal 48")
Ballast Type:
<20THD <10THD
2 Lamp Elec. T8 SO* HI*
*Instant Start Standard
Other dimming options, consult actory.
NOTE:
For T UNV, you must use HIBallast Code.
DA=DALI digital addressable dimming.
Options:
Add appropriate
su ix to catalog
no, ie: (GLR)
Voltage:
120, 277 or
UNV=120-277
0.0 45.0 90.0 FLUX
0 1234 1234 1234
5 1252 1300 1306 122
15 1207 1280 1287 356
25 1100 1182 1215 542
35 962 1020 1058 643
45 799 835 926 650
55 478 457 393 392
65 34 58 39 53
75 4610 7
85 1232
90 111
Model No. LIS6G20LW232120SO
LER = FP - 38.6 IW - 78.0 BF - 1.1
Comparative yearly lighting energy cost per
1000 lumens = $6.22
Report Number: G1206011
Catalog Number: LIS6G20LW232120SO
Lamp: F32 T8
Luminaire: 6" wide Troffer with semi-
specular louver and white reflector.
Ballast: Advance REL-2P32-SC
Report is based on 2850 Lumens per lamp.
Efficiency: 48.6%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.3 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 47.943 5.816
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 6279. 6562. 7277.
55 4631. 4427. 3807.
65 316. 763. 513.
75 86. 129. 215.
85 64. 128. 191.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 0 50 30
RW 70 50 30 50 30 10 50 30 10
1 54 53 51 49 48 47 48 47 46
2 50 47 45 45 43 41 43 42 40
3 47 43 39 41 38 36 39 37 35
4 43 38 35 37 34 32 36 33 31
5 40 35 31 33 30 28 32 30 28
6 37 32 28 30 27 25 30 27 25
7 35 29 25 28 25 22 27 24 22
8 32 26 23 25 22 20 25 22 20
9 30 24 21 24 20 18 23 20 18
10 28 22 19 22 19 16 2 18 16
ZONE LUMENS % LAMP % FIXT
00-030 1021 17.9 36.9
00-040 1664 29.2 60.1
00-060 2707 47.5 97.7
00-090 2769 48.6 100.0
90-180 0000 0.0 000.0
00-180 2769 48.6 100.0
ZONAL LUMEN SUMMARY
0.0 45.0 90.0 FLUX
0 1373 1373 1373
5 1287 1314 1304 125
15 1244 1345 1368 370
25 1149 1246 1264 566
35 1018 1079 1088 681
45 849 926 1005 711
55 579 520 440 441
65 1 52 32 39
75 1496
85 1233
90 112
Model No. LIS6G20PW232120SO
LER = FP - 40.9 IW - 78.0 BF - 1.1
Comparative yearly lighting energy cost per
1000 lumens = $5.86
Report Number: G1206012
Catalog Number: LIS6G20PW232120SO
Lamps: F32 T8
Luminaire: 6" wide Troffer with specular
louver and white reflector.
Ballast: Advance REL-2P32-SC
Report is based on 2850 Lumens per lamp.
Efficiency: 51.6%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 47.943 5.816
CANDELA DISTRIBUTION
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 0 50 30
RW 70 50 30 50 30 10 50 30 10
1 58 56 54 53 51 50 51 50 49
2 54 50 48 48 46 44 46 44 43
3 50 45 42 43 40 38 42 39 37
4 46 41 37 39 36 33 38 35 33
5 43 37 33 35 32 29 34 31 29
6 40 33 29 32 29 26 31 28 26
7 37 30 26 29 26 23 29 26 23
8 34 28 24 27 23 21 26 23 21
9 32 26 22 25 21 19 24 21 19
10 30 24 20 23 20 17 22 19 17
ZONE LUMENS % LAMP % FIXT
00-030 1061 18.6 36.1
00-040 1742 30.6 59.2
00-060 2895 50.8 98.4
00-090 2942 51.6 100.0
90-180 0000 0.0 000.0
00-180 2942 51.6 100.0
ZONAL LUMEN SUMMARY
Reflector:
W
=White Re lector
Mounting Height
Lengthwise Crosswise
Room Luminaires Luminaires
Size 0 Deg Plane 90 Deg Plane
.5 10 .5 10 .5 10 .5 10
30x30 90 85 77 70 88 83 76 68
40x40 90 85 82 76 90 85 82 73
60x30 90 85 80 75 88 83 79 73
60x60 91 86 82 79 91 87 84 78
100x100 91 87 82 78 92 90 87 82
TYPICAL V.C.P.'s
Mounting Height
Lengthwise Crosswise
Room Luminaires Luminaires
Size 0 Deg Plane 90 Deg Plane
.5 10 .5 10 .5 10 .5 10
30x30 85 76 70 69 88 80 76 67
40x40 85 76 72 72 90 84 81 73
60x30 85 76 72 74 89 80 77 69
60x60 85 78 73 74 91 86 83 76
100x100 86 78 73 74 92 88 86 81
TYPICAL V.C.P.'s
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 6672. 7277. 7898.
55 5609. 5038. 4263.
65 13. 684. 421.
75 21. 86. 193.
85 64. 128. 191.
LUMINANCE DATA IN CANDELA/SQ. METER
Body Style:
A=Air Return
S=Static
Standard Lytecel
LI
For NYC Code – Local 3 Manufactured
LN
Ceiling Type:
G= 9/16" or
15/16"Grid
T= Slot Grid
A= 9/16" Tegular
Grid
D= 15/16" Tegular
Grid

Other Lightolier Light Fixture manuals

Lightolier Lytecaster 1004IC User manual

Lightolier

Lightolier Lytecaster 1004IC User manual

Lightolier SS 2 LAMP User manual

Lightolier

Lightolier SS 2 LAMP User manual

Lightolier 9” PENDALYTE SERIES Instruction Manual

Lightolier

Lightolier 9” PENDALYTE SERIES Instruction Manual

Lightolier H9S2GLR254 User manual

Lightolier

Lightolier H9S2GLR254 User manual

Lightolier 40600H1 Guide

Lightolier

Lightolier 40600H1 Guide

Lightolier Calculite C6P38L User manual

Lightolier

Lightolier Calculite C6P38L User manual

Lightolier 4F23 User manual

Lightolier

Lightolier 4F23 User manual

Lightolier Calculite ProSpec PB1A1175 User manual

Lightolier

Lightolier Calculite ProSpec PB1A1175 User manual

Lightolier Calculite ProSpec PA4P3075 User manual

Lightolier

Lightolier Calculite ProSpec PA4P3075 User manual

Lightolier Lytespan 8640WH User manual

Lightolier

Lightolier Lytespan 8640WH User manual

Lightolier Paraplus II PPH2G12FW228 User manual

Lightolier

Lightolier Paraplus II PPH2G12FW228 User manual

Lightolier Calculite Matrix 4X9 User manual

Lightolier

Lightolier Calculite Matrix 4X9 User manual

Lightolier SL103A User manual

Lightolier

Lightolier SL103A User manual

Lightolier Lytespan 8258WH User manual

Lightolier

Lightolier Lytespan 8258WH User manual

Lightolier ProSpec 26056 User manual

Lightolier

Lightolier ProSpec 26056 User manual

Lightolier Lytespan 6320 User manual

Lightolier

Lightolier Lytespan 6320 User manual

Lightolier Lytespan 22GR6 User manual

Lightolier

Lightolier Lytespan 22GR6 User manual

Lightolier PRISMALYTE plus PRA2GRFVA26U User manual

Lightolier

Lightolier PRISMALYTE plus PRA2GRFVA26U User manual

Lightolier Lytecaster 1082 User manual

Lightolier

Lightolier Lytecaster 1082 User manual

Lightolier Lytespan 9630 User manual

Lightolier

Lightolier Lytespan 9630 User manual

Lightolier Lytecaster 1101HIE User manual

Lightolier

Lightolier Lytecaster 1101HIE User manual

Lightolier Calculite DR User manual

Lightolier

Lightolier Calculite DR User manual

Lightolier H9S2GLR1FT User manual

Lightolier

Lightolier H9S2GLR1FT User manual

Lightolier 8279EN User manual

Lightolier

Lightolier 8279EN User manual

Popular Light Fixture manuals by other brands

Philips Calculite C4T4GA-MHT4RF specification

Philips

Philips Calculite C4T4GA-MHT4RF specification

Elation ELAR DW BRICK instruction manual

Elation

Elation ELAR DW BRICK instruction manual

Kichler Lighting 16140SS30 instructions

Kichler Lighting

Kichler Lighting 16140SS30 instructions

Casablanca K2HB Instructions for mounting

Casablanca

Casablanca K2HB Instructions for mounting

LUCE&LIGHT RIVER WALL 4.0 installation instructions

LUCE&LIGHT

LUCE&LIGHT RIVER WALL 4.0 installation instructions

Commercial Electric 54197201 Use and care guide

Commercial Electric

Commercial Electric 54197201 Use and care guide

Parkside PBSL 5000 B1 Operation and safety notes

Parkside

Parkside PBSL 5000 B1 Operation and safety notes

Flash F7100518 user manual

Flash

Flash F7100518 user manual

GT-Lite GT-421CP user guide

GT-Lite

GT-Lite GT-421CP user guide

ANSMANN NL25B Operation manual

ANSMANN

ANSMANN NL25B Operation manual

Cameo NANO BEAM 300 user manual

Cameo

Cameo NANO BEAM 300 user manual

Cooper Lighting DP AXIO specification

Cooper Lighting

Cooper Lighting DP AXIO specification

Flash F1700034 user manual

Flash

Flash F1700034 user manual

Chauvet DMX Abyss DMX-450 user guide

Chauvet

Chauvet DMX Abyss DMX-450 user guide

Emos ZM5121 manual

Emos

Emos ZM5121 manual

MAUL MAULpulse quick start guide

MAUL

MAUL MAULpulse quick start guide

Chauvet LEG-3000 supplementary guide

Chauvet

Chauvet LEG-3000 supplementary guide

GE Lighting T5 Fluorescent Fixture Series Installation, use and maintenance manual

GE Lighting

GE Lighting T5 Fluorescent Fixture Series Installation, use and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.