HP90 Recessed Fluorescent H9S2GLR214 or 224
Page 2 of 2 Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens
Static, 2 Lamp T5
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR224UNVPG
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK92X2 .
Electrical Wiring Options: Consult factory.
For motion or light sensor. See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 14W luminaires in a room cavity ratio of 1,
with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .86.
To reduce glare the average brightness at 65° shall not exceed 2540 candelas per
square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall
not be less than 75.3%.
Materials: Chassis parts are die-formed code gauge steel.
Lamp Shield: Linear prismatic translucent DR acrylic lens.
Specifications (continued)
Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white
acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular alu-
minum .95% reflectance.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is
within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal
Laws. See: www.lamprecycle.org
Options:
Add appropriate
suffix to catalog
no., ie: (A)
HP90
Direct/Indirect
Recessed
S
Body Style:
S= Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens Lamp:
(By Others)
14=T5 14W
24=T5HO 24W
(Nominal 24")
R
Reflector:
Specular
Aluminum
2
Lamp
Quantity
2=2 Lamp
Ballast Type:
<10THD
2 Lamp Elec. T5 PG ††
(14 Watt)
2 Lamp Elec. T5HO PG ††
(24 Watt)
††Program Rapid Start (UNV only)
0.0 45.0 90.0 FLUX
0 622 622 622
5 620 620 623 59
15 595 605 614 171
25 548 572 593 264
35 481 521 559 326
45 397 456 507 351
55 299 375 440 333
65 198 184 364 280
75 100 180 226 178
85 21 27 20 35
90 222
Model No. H9S2GLR214UNVPG
LER = FP - 68.1 IW - 31.1 BF - 1.06
Comparative yearly lighting energy cost per
1000 lumens = $3.53
Report Number: G2010021
Catalog Number: H9S2GLR214UNVPG
Lamps: (2) F14T5
Luminaire: HP90 2' x 2' with linear
prismatic lens.
Ballast: ICN-2S28 Advanced
Report is based on 1200 Lumens per lamp.
Efficiency: 83.2%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.3 1.4
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 22.800 22.800
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1656. 1902. 2115.
55 1538. 1928. 2263.
65 1382. 1982. 2540.
75 1140. 2051. 2575.
85 711. 917. 677.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 90 86 82 80 78 75 77 75 73
02 81 74 68 70 65 61 67 63 59
03 74 65 57 61 55 50 58 54 50
04 67 57 49 54 47 43 52 46 42
05 62 51 43 48 41 36 46 41 36
06 57 45 38 43 37 32 42 36 31
07 53 41 34 39 33 28 38 32 28
08 49 37 30 36 29 25 35 29 25
09 46 34 27 33 27 22 32 26 22
10 43 32 25 30 24 20 29 24 20
ZONE LUMENS % LAMP % FIXT
00-030 494 20.6 24.7
00-040 820 34.2 41.1
00-060 1504 62.7 75.3
00-090 1997 83.2 100.0
90-180 0000 0.0 000.0
00-180 1997 83.2 100.0
ZONAL LUMEN SUMMARY
Model No. H9S2GLR224UNVPG
LER = FP - 57.2 IW -{.{BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $4.19
Report Number: G2007082
Catalog Number: H9S2GLR224UNVPG
Lamps: (2) F24T5 HO
Luminaire: HP90 2' x 2' with linear
prismatic lens.
Ballast: QTP2X39-24T5HO/UNV Osram
Report is based on 1760 Lumens per lamp.
Efficiency: 80.3%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.4
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 22.800 22.800
0.0 45.0 90.0 FLUX
0 894 894 894
5 889 890 893 85
15 852 867 880 245
25 781 818 848 377
35 687 744 800 465
45 547 651 732 499
55 397 538 642 473
65 246 406 527 393
75 114 253 326 246
85 26 37 29 47
90 333
CANDELA DISTRIBUTION0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2081. 2477. 2785.
55 1862. 2523. 3011.
65 1566. 2584. 3354.
75 1185. 2630. 3388.
85 802. 1142. 895.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 87 83 79 78 75 73 75 72 70
02 79 72 66 67 63 59 65 61 58
03 71 63 56 59 53 49 57 52 48
04 65 55 48 52 46 41 50 45 41
05 60 49 42 46 40 35 45 39 35
06 55 44 37 42 36 31 40 35 31
07 51 40 33 38 32 27 37 31 27
08 47 36 29 35 29 24 34 28 24
09 44 33 26 32 26 22 31 25 22
10 41 31 24 29 24 20 29 23 20
ZONE LUMENS % LAMP % FIXT
00-030 706 20.1 25.0
00-040 1171 33.3 41.4
00-060 2143 60.9 75.8
00-090 2828 80.3 100.0
90-180 000000.0 000.0
00-180 2828 80.3 100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277
H9 Standard HP90
HY For NYC Code – I.B.E.W. Manufactured
Job Information Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 11/11
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group Section 5/Folio M32-15 Rev.C