manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lightolier
  6. •
  7. Light Fixture
  8. •
  9. Lightolier PRISMALYTE plus PRA2GRFVA26U User manual

Lightolier PRISMALYTE plus PRA2GRFVA26U User manual

This manual suits for next models

3

Other Lightolier Light Fixture manuals

Lightolier RADIANCE PENDANT FIXTURES Guide

Lightolier

Lightolier RADIANCE PENDANT FIXTURES Guide

Lightolier Lytecaster 1304 User manual

Lightolier

Lightolier Lytecaster 1304 User manual

Lightolier SW STRIP User manual

Lightolier

Lightolier SW STRIP User manual

Lightolier LL4MF8LX254 User manual

Lightolier

Lightolier LL4MF8LX254 User manual

Lightolier Paralyte 2424 PLA2G9LS26U User manual

Lightolier

Lightolier Paralyte 2424 PLA2G9LS26U User manual

Lightolier 8279EN User manual

Lightolier

Lightolier 8279EN User manual

Lightolier Calculite ProSpec PA1P3075 User manual

Lightolier

Lightolier Calculite ProSpec PA1P3075 User manual

Lightolier ProSpec 26800 User manual

Lightolier

Lightolier ProSpec 26800 User manual

Lightolier Lytespan 6320 User manual

Lightolier

Lightolier Lytespan 6320 User manual

Lightolier Lytespan 6170 User manual

Lightolier

Lightolier Lytespan 6170 User manual

Lightolier 4R28 User manual

Lightolier

Lightolier 4R28 User manual

Lightolier Prospec 26190 User manual

Lightolier

Lightolier Prospec 26190 User manual

Lightolier Calculite 8038 User manual

Lightolier

Lightolier Calculite 8038 User manual

Lightolier CDB2SPF2FT User manual

Lightolier

Lightolier CDB2SPF2FT User manual

Lightolier 4SB115 User manual

Lightolier

Lightolier 4SB115 User manual

Lightolier Arco 4531 series Guide

Lightolier

Lightolier Arco 4531 series Guide

Lightolier SC Series User manual

Lightolier

Lightolier SC Series User manual

Lightolier QHE2GPFOP228 User manual

Lightolier

Lightolier QHE2GPFOP228 User manual

Lightolier Lytecaster 302ESX User manual

Lightolier

Lightolier Lytecaster 302ESX User manual

Lightolier QVS2GPTOS2FT User manual

Lightolier

Lightolier QVS2GPTOS2FT User manual

Lightolier Lytespan 9379 User manual

Lightolier

Lightolier Lytespan 9379 User manual

Lightolier Lytespan 8235WH User manual

Lightolier

Lightolier Lytespan 8235WH User manual

Lightolier Lytespan 8180WH User manual

Lightolier

Lightolier Lytespan 8180WH User manual

Lightolier VTS2GPK332 User manual

Lightolier

Lightolier VTS2GPK332 User manual

Popular Light Fixture manuals by other brands

Veko Magnus manual

Veko

Veko Magnus manual

Cooper Lighting Halo L10538 specification

Cooper Lighting

Cooper Lighting Halo L10538 specification

Emos CLASSIC ZY1431T manual

Emos

Emos CLASSIC ZY1431T manual

Westinghouse Outdoor Lighting Fixture owner's manual

Westinghouse

Westinghouse Outdoor Lighting Fixture owner's manual

Hedler C 12 silent Operation manual

Hedler

Hedler C 12 silent Operation manual

Blizzard Lighting Puck: CSI manual 

Blizzard Lighting

Blizzard Lighting Puck: CSI manual 

Energetic Lighting ELYSL-5004 Series installation instructions

Energetic Lighting

Energetic Lighting ELYSL-5004 Series installation instructions

Lightmaxx Shaft 5R user manual

Lightmaxx

Lightmaxx Shaft 5R user manual

Triarch 31083 Assembly instructions

Triarch

Triarch 31083 Assembly instructions

Philips 32614 Series user manual

Philips

Philips 32614 Series user manual

IKEA TIVED Assembly instructions

IKEA

IKEA TIVED Assembly instructions

Chauvet Professional ROGUE R1 BEAM WASH user manual

Chauvet Professional

Chauvet Professional ROGUE R1 BEAM WASH user manual

Martin MAC 250 Krypton user manual

Martin

Martin MAC 250 Krypton user manual

Cooper Lighting Halo L3232E Specification sheet

Cooper Lighting

Cooper Lighting Halo L3232E Specification sheet

Stageline ODW-2410RGBW instruction manual

Stageline

Stageline ODW-2410RGBW instruction manual

ArtFox Beam 15R extreme manual

ArtFox

ArtFox Beam 15R extreme manual

GLG multispot 330 user manual

GLG

GLG multispot 330 user manual

Home Accents Holiday TY052-1924-1 Assembly instructions

Home Accents Holiday

Home Accents Holiday TY052-1924-1 Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group S ction 1A/Folio E20-32 R v. A
Lightolier is a Philips group brand
09/09
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Prismalyte Plus PRA2GRFVA26U or 217
Page 1 of 2 2' x 2' Recessed Fluorescent, Floating Lens Frame, Black Reveal
Static or Air Supply/Return, 2 Lamp, T8
• 5" deep body.
• 2-9/16" lamp to lens for better lamp obscuration.
• 71.6% efficient (2 lamp T8).
• Black housing exterior for cooler ballast operating temperature.
• Clean contoured interior.
• Eyeleted heat removal vents in fixture ends.
• Hemmed over side rails for maximum safety.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips.
• Door jamb finished black on four sides for positive light stop.
• True mitered corner aluminum lens frame.
• Spring loaded rooster head latches.
• 18 gauge steel hinges.
• Construction to meet NYC Code Requirements or Chicago Plenum is
available.
Mounting M thods Dim nsions
23-7/8"
(606mm)
5"
(127mm)
15-11/16"
(398mm)
Air supply slots
(PRA only)
2"x 2-1/2" access plate
with two K.O.s (7/8" dia.)
24" (610mm)
5" (127mm)
Gxpos d T-grid c iling. Txpos d slot T-grid c iling.
drywall kit. (S options)
1/4" max.
1-1/2" max.
15/16"
or 1"
24"
Type “G”
Fixture
Support
(by others)
Drywall Kit
(See Options)
Drywall
(by others)
1-7/8" max.
9/16"
24"
arthquak clip
install d
(lay-in grid)
arthquak clip
b for
installation
Order Catalog Number: FK92X2.
24" (610mm)
5" (127mm)
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group S ction 1A/Folio E20-32 R v. A
Job Information Type:
Lightolier is a Philips group brand
Prismalyte Plus PRA2GRFVA26U or 217
Page 2 of 2 2' x 2' Recessed Fluorescent, Floating Lens Frame, Black Reveal
Static or Air Supply/Return, 2 Lamp, T8
Ord ring Information
Explanation of Catalog Number. Example: PRA2GRFVA26UUNVHI
Options/Acc ssori s
Sp cial L ns s: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average
weight per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz.
average weight per square foot.
Radio Int rf r nc Filt r:
To order one RIF per fixture; SUFFIX: R.
To order one RIF per ballast; SUFFIX: B.
Air Closur Strip: SUFFIX ACS2 (factory installed).
El ctrical Wiring Options: Consult factory.
Drywall Kit: Order Catalog Number: FK92X2.
(Request Folio OA30-10 Rev. A).
Chicago Pl num: SUFFIX: C.
Sp cifications
P rformanc : In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1,
reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .76. To prevent
glare the VCP shall be not less than 41 either lengthwise or crosswise (at 100fc level) and
the average brightness at 65° shall not exceed 2572 candelas per square meter. To control
veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.9%.
Air Handling: (PRA only) side air passages for air supply or air return. Supply air is dis-
charged vertically. Optional side closure strips. Air return is also provided through the lamp
compartment through fixture body ends.
Sp cifications (continu d)
Mat rials:Chassis parts are die-formed code gauge cold rolled steel. Housing
with side rails hemmed over and hous-
ing ends turned-in for safe handling.
Finish:Chassis xt rior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86%
reflectance. Phosphate undercoating.
L ns s:VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge,
.095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12 with 7.8 oz. average
weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot.
El ctrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use
wire suitable for at least 90°.
Lab ls: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp.
Manage in accord with Disposal Laws. See: www.lamprecycle.org
Photom try Mod l No. PRA2GRFVA26U120SO LER = FP - 58.4 IW - 56.5 BF - 0.87
Comparative yearly lighting energy cost per 1000 lumens = 4.25
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
co ffici nts of utilization — zonal cavity m thod (effective floor cavity reflectance 0.20)
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 79 76 73 71 69 67 68 66 65
2 72 67 62 63 60 57 61 58 55
3 66 60 54 56 52 49 54 51 48
4 61 53 48 51 46 42 49 45 42
5 57 48 42 46 41 37 44 40 37
6 53 44 38 42 37 33 41 36 33
7 49 40 34 38 33 29 37 33 29
8 46 36 31 35 30 26 34 30 26
9 43 34 28 32 27 24 32 27 24
10 40 31 26 30 25 22 29 25 22
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 57 61 67 73 54 58 64 70
20 30 49 53 58 64 46 50 55 60
20 40 46 48 53 57 42 45 49 54
20 60 42 45 48 52 38 41 43 48
30 20 58 63 67 72 56 61 65 70
30 30 50 54 58 63 47 51 55 60
30 40 46 49 52 56 42 45 49 53
30 60 42 45 47 50 39 41 43 47
30 80 41 43 43 47 38 39 40 43
40 20 60 64 68 72 58 63 67 70
40 30 51 55 59 63 49 53 57 61
40 40 47 50 53 56 44 47 50 53
40 60 43 46 47 50 40 42 43 47
40 80 42 43 43 46 38 40 40 43
40 100 42 43 42 44 39 39 38 40
60 30 52 56 60 64 51 55 58 62
60 40 48 50 53 57 45 48 51 55
60 60 44 46 47 50 41 43 44 48
60 80 42 44 43 46 39 40 40 43
60 100 42 43 42 44 39 39 38 40
100 40 51 53 55 59 49 52 54 57
100 60 47 48 48 52 45 46 46 50
100 80 45 45 45 48 43 43 42 45
100 100 44 44 43 45 42 41 40 41
room cavity ratio
luminaries lengthwise
luminaries crosswise
Prismalyt
Plus:
Floating
Lens Frame
Recessed
Fluorescent
Troffer
Body Styl :
A=Air
Handling
S=Static
2
Fixtur
Width
C iling Typ :
G= Grid
(lay-in T bar)
T= Slot grid or
two-directional
concealed T
see options)
RF
L ns Fram :
RF=1/2" regressed
floating aluminum
frame with 7/16"
black reveal four
sides.
L ns Shi lding
Typ :
VA=Virgin acrylic
(standard), see
options and
consult factory
2
Lamp
Quantity
Lamp Typ /
Fixtur L ngth:
6U =
6"U Lamp T8
17 =
T8
(Nominal 24")
Not : For Lin ar
T5 Lamp option,
consult factory
Options:
Add appropriate suffix to
catalog no., ie: (C)
Ballast Typ :
<20THD <10THD
1 2 Lamp Elec. T8 SO * HI*
LOL T8 Dimming PS –
*Instant Start Standard
Other dimming options. Consult factory.
NOTE:
For T8 UNV, you must use H
I
Ballast Code.
Voltag :
120, 277 or
UNV=120-277
PR Standard Prismalyte Plus
PK For NYC Code – I.B.E.W. Manufactured
PX For NYC Code – Local 3 Manufactured