manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lightolier
  6. •
  7. Light Fixture
  8. •
  9. Lightolier PRISMALYTE plus PRA2GRFVA432 User manual

Lightolier PRISMALYTE plus PRA2GRFVA432 User manual

Other Lightolier Light Fixture manuals

Lightolier 4F23 User manual

Lightolier

Lightolier 4F23 User manual

Lightolier Calculite C4MRD CCDW User manual

Lightolier

Lightolier Calculite C4MRD CCDW User manual

Lightolier 4SB115 User manual

Lightolier

Lightolier 4SB115 User manual

Lightolier Calculite S6132BUES User manual

Lightolier

Lightolier Calculite S6132BUES User manual

Lightolier Lytespan 7178 User manual

Lightolier

Lightolier Lytespan 7178 User manual

Lightolier Lytecaster 302ESX User manual

Lightolier

Lightolier Lytecaster 302ESX User manual

Lightolier Lytecaster 2045 User manual

Lightolier

Lightolier Lytecaster 2045 User manual

Lightolier ProSpec 37224 User manual

Lightolier

Lightolier ProSpec 37224 User manual

Lightolier Calculite ProSpec PB4H3870 User manual

Lightolier

Lightolier Calculite ProSpec PB4H3870 User manual

Lightolier LYEDROP FIXTURE Guide

Lightolier

Lightolier LYEDROP FIXTURE Guide

Lightolier Lytecaster 1024 User manual

Lightolier

Lightolier Lytecaster 1024 User manual

Lightolier Eye-QLB EYS442FX354 User manual

Lightolier

Lightolier Eye-QLB EYS442FX354 User manual

Lightolier Lytecaster 2002P1 User manual

Lightolier

Lightolier Lytecaster 2002P1 User manual

Lightolier P7006 User manual

Lightolier

Lightolier P7006 User manual

Lightolier Calculite ProSpec PA4A7050 User manual

Lightolier

Lightolier Calculite ProSpec PA4A7050 User manual

Lightolier ProSpec 26030W User manual

Lightolier

Lightolier ProSpec 26030W User manual

Lightolier Calculite AS4LS User manual

Lightolier

Lightolier Calculite AS4LS User manual

Lightolier PristineHW Series User manual

Lightolier

Lightolier PristineHW Series User manual

Lightolier Calculite Matrix 4X9 User manual

Lightolier

Lightolier Calculite Matrix 4X9 User manual

Lightolier 6706S2UEM User manual

Lightolier

Lightolier 6706S2UEM User manual

Lightolier Calculite ProSpec PA1A7050 User manual

Lightolier

Lightolier Calculite ProSpec PA1A7050 User manual

Lightolier CA3FMR SERIES User manual

Lightolier

Lightolier CA3FMR SERIES User manual

Lightolier Lytespan 9170 User manual

Lightolier

Lightolier Lytespan 9170 User manual

Lightolier Lytecaster 1129 User manual

Lightolier

Lightolier Lytecaster 1129 User manual

Popular Light Fixture manuals by other brands

Veko Magnus manual

Veko

Veko Magnus manual

Cooper Lighting Halo L10538 specification

Cooper Lighting

Cooper Lighting Halo L10538 specification

Emos CLASSIC ZY1431T manual

Emos

Emos CLASSIC ZY1431T manual

Westinghouse Outdoor Lighting Fixture owner's manual

Westinghouse

Westinghouse Outdoor Lighting Fixture owner's manual

Hedler C 12 silent Operation manual

Hedler

Hedler C 12 silent Operation manual

Blizzard Lighting Puck: CSI manual 

Blizzard Lighting

Blizzard Lighting Puck: CSI manual 

Energetic Lighting ELYSL-5004 Series installation instructions

Energetic Lighting

Energetic Lighting ELYSL-5004 Series installation instructions

Lightmaxx Shaft 5R user manual

Lightmaxx

Lightmaxx Shaft 5R user manual

Triarch 31083 Assembly instructions

Triarch

Triarch 31083 Assembly instructions

Philips 32614 Series user manual

Philips

Philips 32614 Series user manual

IKEA TIVED Assembly instructions

IKEA

IKEA TIVED Assembly instructions

Chauvet Professional ROGUE R1 BEAM WASH user manual

Chauvet Professional

Chauvet Professional ROGUE R1 BEAM WASH user manual

Martin MAC 250 Krypton user manual

Martin

Martin MAC 250 Krypton user manual

Cooper Lighting Halo L3232E Specification sheet

Cooper Lighting

Cooper Lighting Halo L3232E Specification sheet

Stageline ODW-2410RGBW instruction manual

Stageline

Stageline ODW-2410RGBW instruction manual

ArtFox Beam 15R extreme manual

ArtFox

ArtFox Beam 15R extreme manual

GLG multispot 330 user manual

GLG

GLG multispot 330 user manual

Home Accents Holiday TY052-1924-1 Assembly instructions

Home Accents Holiday

Home Accents Holiday TY052-1924-1 Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

For Factory Technical Information: (97 ) 657-7600 • Fax (97 ) 65 -0595
631 Airport Road, Fall River, MA 02720 • (50 ) 679- 131 • Fax (50 ) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group Section 1A/Folio E20-44 Rev. A
Lightolier is a Philips group brand
09/09
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Prismalyte Plus PRA2GRFVA432
Page 1 of 2 2' x 4' Recessed Fluorescent, Floating Lens Frame, Black Reveal
Static or Air Supply/Return, 4 Lamp, T or T5
• 5" deep body.
• 2-9/16" lamp to lens for better lamp obscuration.
• 76.7% efficient (4 lamp T8).
• Black housing exterior for cooler ballast operating temperature.
• Clean contoured interior.
• Eyeleted heat removal vents in fixture ends.
• One-piece housing has ribbed construction for added strength.
• Hemmed over side rails for maximum safety.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips.
• Door jamb finished black on four sides for positive light stop.
• True mitered corner aluminum lens frame.
• Spring loaded rooster head latches.
• 18 gauge steel hinges.
• Construction to meet NYC Code Requirements or Chicago Plenum is
available.
Mounting Methods Dimensions
Gexposed T-grid ceiling. Texposed slot T-grid ceiling.
drywall kit. (See options)
1/4" max.
1-1/2" max.
15/16"
or 1"
24"
Type “G”
Fixture
Support
(by others)
Drywall Kit
(See Options)
Drywall
(by others)
1-7/8" max.
9/16"
24"
6" (152mm) Air supply slots
(PRA only)
39-1/4" (997mm)
47-31/32" (1218mm)
2" x 2-1/2" access plate
with two K.O.s
(7/8" dia.)
24" (610mm)
5" (127mm)
earthquake clip
installed
(lay-in grid)
earthquake clip
before
installation
Order Catalog Number: FK92X4.
For Factory Technical Information: (97 ) 657-7600 • Fax (97 ) 65 -0595
631 Airport Road, Fall River, MA 02720 • (50 ) 679- 131 • Fax (50 ) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group Section 1A/Folio E20-44 Rev. A
Job Information Type:
Lightolier is a Philips group brand
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 84 81 78 76 74 72 73 71 69
2 77 71 67 67 64 60 65 62 59
3 71 63 58 60 55 52 58 54 51
4 65 57 51 54 49 45 52 48 44
5 60 51 45 49 43 39 47 43 39
6 56 46 40 44 39 35 43 38 34
7 52 42 36 40 35 31 39 34 31
8 49 39 32 37 32 28 36 31 28
9 45 36 30 34 29 25 34 29 25
10 43 33 27 32 27 23 31 26 23
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height
WL8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 61 65 72 79 58 63 69 76
20 30 54 58 63 69 50 54 60 66
20 40 50 53 58 62 45 49 54 59
20 60 46 49 52 57 41 45 48 53
30 20 62 67 71 77 60 65 69 75
30 30 54 58 62 67 51 55 60 65
30 40 50 53 56 60 46 49 53 57
30 60 46 49 51 54 41 45 47 51
30 60 44 46 47 51 39 42 43 47
40 20 63 68 72 76 62 67 71 75
40 30 55 59 63 67 53 57 61 65
40 40 50 53 57 60 47 50 54 57
40 60 46 49 51 54 42 45 47 51
40 80 44 46 47 50 40 42 43 47
40 100 44 45 45 48 39 41 41 44
60 30 56 60 64 67 54 59 62 66
60 40 51 54 57 60 48 52 55 58
60 60 46 49 50 54 43 46 47 51
60 80 44 46 47 50 40 43 43 46
60 100 43 45 45 47 39 41 41 43
100 40 53 56 58 62 52 55 57 61
100 60 49 51 52 55 46 49 50 53
100 80 46 48 48 51 43 45 45 48
100 100 45 46 45 48 41 42 42 44
Prismalyte Plus PRA2GRFVA432
Page 2 of 2 2' x 4' Recessed Fluorescent, Floating Lens Frame, Black Reveal
Static or Air Supply/Return, 4 Lamp, T or T5
Ordering Information
Explanation of Catalog Number. Example: PRA2GRFVA432UNVH4
Options/Accessories
Special Lenses: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average
weight per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz.
average weight per square foot.
Radio Interference Filter:
To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast;
SUFFIX: B.
Air Closure Strip: SUFFIX ACS4 (factory installed).
Electrical Wiring Options: Consult factory.
Drywall Kit: Order Catalog Number: FK92X4.
(Request Folio OA30-10 Rev. A).
Chicago Plenum: SUFFIX: C.
Specifications
Performance: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1,
reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .81. To prevent
glare the VCP shall be not less than 43 either lengthwise or crosswise (at 100fc level) and
the average brightness at 65° shall not exceed 2805 candelas per square meter. To control
veiling reflections, luminaire output in the 30°-90° zone shall not be less than 67.3%.
Air Handling: (PRA only) side air passages for air supply or air return. Supply air is dis-
charged vertically. Optional side closure strips. Air return is also provided through the lamp
compartment through fixture body ends.
Specifications (continued)
Materials:Chassis parts are die-formed code gauge cold rolled steel. Housing
with side rails hemmed over and hous-
ing ends turned-in for safe handling.
Finish:Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86%
reflectance. Phosphate undercoating.
Lenses:VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge,
.095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12 with 7.8 oz. average
weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use
wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp.
Manage in accord with Disposal Laws. See: www.lamprecycle.org
Photometry Model No. PRA2GRFVA432120O4 LER = FP - 68.7 IW - 109.5 BF - 0.86
Comparative yearly lighting energy cost per 1000 lumens = 3.49
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
2
Fixture
Width
Ceiling Type:
G= Grid
(lay-in T bar)
T= Slot grid or
two-directional
concealed T
see options)
RF
Lens Shielding
Type:
VA=Virgin acrylic
(standard), see
options and
consult factory
4
Lamp
Quantity
Options:
Add appropriate suffix to
catalog no., ie: (C)
Ballast Type:
<20THD <10THD
2-2 Lamp Elec. T SO * HI*
1-4 Lamp Elec. T O4 * H4 *
2-2 Lamp 2 W Elec. T5 –PI
2-2 Lamp 2 W/54W Elec. T5 –PG
1-4 Lamp 54W Elec. T5 –PV
LOL T Dimming PS –
Other dimming options. Consult factory.
*Instant Start Standard
†Instant Start (120, 277 or UNV)
††Instant Start (UNV only)
NOTE:
For T8 UNV, you must use H
I
,H4 Ballast Code.
room cavity ratio
luminaries lengthwise
luminaries crosswise
Voltage:
120, 277 or
UNV=120-277
Lamp Type/
Fixture Length:
32=32W T
28=2 W T5
54=54W T5
(Nominal 4 ")
Prismalyte
Plus:
Floating
Lens Frame
Recessed
Fluorescent
Troffer
Body Style:
A=Air
Handling
S=Static
PR Standard Prismalyte Plus
PK For NYC Code – I.B.E.W. Manufactured
PX For NYC Code – Local 3 Manufactured
Lens Frame:
RF=1/2" regressed
floating aluminum
frame with 7/16"
black reveal four
sides.