Lighting Systems Baselyte-BSL31
Page 2 of 4 1 Light T5 HO Wall Mount Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Report No: 2101686
Lamps: F54T5
Lumens per Lamp: 4650
Efficiency: 58.3%
Up: 100.0% Down: 0.0%
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE
CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 45 90 135 180
180 464 464 464 464 464
175 531 511 461 414 390
165 658 596 447 311 261
155 825 665 419 235 245
145 1019 781 378 222 229
135 1203 878 328 201 207
125 1409 977 268 172 172
115 1588 1048 199 133 133
105 977 1012 116 90 85
95 237 244 31 33 36
90 39 18 2 6 7
85 00000
75 00000
65 00000
55 00000
45 00000
35 00000
25 00000
15 00000
5 00000
0 00000
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 55 55 55 47 47 47 32 32 32
1 48 46 44 41 39 38 28 27 26
2 42 38 36 35 33 31 24 23 21
3 36 32 29 31 28 25 21 19 18
4 32 28 25 27 24 21 19 17 15
5 28 24 21 24 21 18 16 14 13
6 25 21 18 21 18 15 15 12 11
7 22 18 15 19 16 13 13 11 9
8 20 16 13 17 14 11 12 10 8
9 18 14 11 16 12 10 11 8 7
10 16 13 10 14 11 9 10 7 6
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180 2709
2709
0 0
100.0
100.0
0
58.3
58.3
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 55 55 55 47 47 47 32 32 32
1 48 46 44 41 39 38 28 27 26
2 42 38 36 35 33 31 24 23 21
3 36 32 29 31 28 25 21 19 18
4 32 28 25 27 24 21 19 17 15
5 28 24 21 24 21 18 16 14 13
6 25 21 18 21 18 15 15 12 11
7 22 18 15 19 16 13 13 11 9
8 20 16 13 17 14 11 12 10 8
9 18 14 11 16 12 10 11 8 7
10 16 13 10 14 11 9 10 7 6
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180 2709
2709
0 0
100.0
100.0
0
58.3
58.3
Module Lengths & Mounting Distances Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module Joiner End Set Mount Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run 1 1 1 1
16’ run 2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
Joiner
BSLEWW = wall mount standard white
End Set
BSLJW = wall mount joiner
System Components & Accessories
Non-Power Wall Mount Power Wall Mount
BSLWP1 = 1-power mount
BSLWP2 = 2-power mount
BSLWN = non-power wall mount