Louver IC Series
Page 1 of 2 2' x 4' Recessed Fluorescent, 3" 12, 1 , 24 or 32 Cell Parabolic Louver
Static, 2,3 or 4 Lamp, T
• UL Listed Type IC Recessed Luminaire
(Intended for Direct Thermal Insulation Contact).
• Construction provides optimum thermal performance.
• Ballast mounted with thermal heat sink.
• Ideal for fire rated ceilings.
• One piece housing.
• Black exterior for cooler ballast operating temperature.
• 5" deep body.
• 77.7% efficient (3 light 18 cell)
• Hemmed over side rails for maximum safety.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips.
• Pre-anodized aluminum parabolic louver.
• Spring loaded rooster head latches.
• 18 gauge steel hinges.
• Louver has protective film dust guard.
• Vertical grain louver eliminates reflected lamp images on cross baffle.
• Construction to meet NYC Code or Chicago Plenum requirements
is available.
Mounting Methods Dimensions
Gexposed T-grid ceiling. Texposed slot T-grid ceiling.
drywall kit.
1/4" max.
15/16"
or 1"
24"
Type “G”
Fixture
Support
(by others)
Drywall Kit
(See Options)
Drywall
(by others)
9/16"
24"
1-1/2" max. 1-7/8" max.
Order Catalog Number: FK92X4.
24" (610mm)
5"
(127mm)
6"
(152mm)
Air supply slots
(DPA only)
47-31/32" (1218mm)
2" x 2-1/2" access plate
with two K.O.s
(7/8" dia.)
3" Nominal
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
For Factory Technical Information: (97 ) 657-7600 • Fax (97 ) 65 -0595 0 /10
631 Airport Road, Fall River, MA 02720 • (50 ) 679- 131 • Fax (50 ) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group Section 7/Folio Q80-25 Rev. A
Louver IC Series
Page 2 of 2 2' x 4' Recessed Fluorescent, 3" 12, 1 , 24 or 32 Cell Parabolic Louver
Static, 2,3 or 4 Lamp, T
Options/Accessories
Plaster Frame: Catalog Number: PF24.
Radio Interference Filter:
To order one RIF per fixture; SUFFIX: R.
To order one RIF per ballast; SUFFIX: B.
Fusing: Internal fast-blow fusing. SUFFIX A. Internal slow-blow fusing. SUFFIX C.
Electrical Wiring Options: Consult factory.
Drywall Kit: Order Catalog Number: FK92X4. (Request Folio OA30-10 Rev. A).
Chicago Plenum: SUFFIX: C.
Specifications
Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1,
reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .85. To prevent
glare the VCP shall be not less than 75 either lengthwise or crosswise (at 100fc level) and
the average brightness at 65° shall not exceed 1606 candelas per square meter. To control
veiling reflections, luminaire output in the 30°-90° zone shall not be less than 72.0%.
Materials:Chassis parts are die-formed code gauge cold rolled steel. Housing
is ribbed for
rigidity with side rails hemmed over and housing ends turned-in for safe handling.
Specifications (continued)
Louver is pre-anodized aluminum.
Finish:Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel
minimum 86% reflectance. Rust preventative undercoating. Louver–low iridescence semi-specular
anodized vertical grain aluminum reflector sheet is standard.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See:
www.lamprecycle.org
SECTION 7/Folio Q80-25
IC Series:
Recessed
Parabolic
suitable for
Thermal
Insulation
Contact
S
Body Style:
S=Static
2
Fixture
Width
Lamp
Quantity
2=2 lamps
3=3 lamps
4=4 lamps
Ballast Type:
<20THD <10THD
1 & 2 Lamp Elec. T SO * HI*
1-3 Lamp Elec. T 03 * H3 *
1-4 Lamp Elec. T 04 * H4 *
*Instant Start Standard
†Instant Start (120, 277 or UNV)
††Program Rapid Start (UNV only)
NOTE:
For T8 UNV, you must use H
I
Ballast Code.
Ordering Information
Explanation of Catalog Number. Example: ICS2G12LS232120UNVHI
Ceiling Type:
G= Grid
(lay-in T bar)
T= Slot grid
Number of
Cells:
12=2 rows
of 6
18=3 rows
of 6
24=3 rows
of
32=4 rows
of
Louver Finish:
L= Low iridescence
Semi-specular
(standard)
P=Low iridescence
Specular
W=White Baked
Enamel
S
Single "V"
Reflector Voltage:
120, 277 or
UNV=120-277
Lamp Type/
Fixture Length:
32=32W T
(Nominal 4 ")
IC Standard IC Parabolic
IY For NYC Code – I.B.E.W. Manufactured
0.0 45.0 90.0 FLUX
0 1571 1571 1571
5 1572 1569 1573 150
15 1511 1547 1579 438
25 1399 1489 1585 689
35 1242 1411 1593 888
45 1033 1330 1777 1057
55 744 1158 1217 939
65 274 415 322 356
75 17 30 38 42
85 1112
90 000
Model No. ICS2G12LS232120SO
LER = FP - 65.5 IW - 61.6 BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = 3.67
Report Number: ITL49787
Catalog Number: ICS2G12LS232120S0
Lamp: (2) F32 T8
Luminaire: IC 2' X 4' Troffer with 2X6
Semi-Specular Louver
Ballast: M3-RN-T81LL-D-120
Report is based on 2850 Lumens per lamp.
Efficiency: 80.0%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.3 1.6
Shielding Angles: 25 29
Plane: 0-Deg 90-Deg
Luminous Length: 45.125 21.000
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2389. 3075. 4109.
55 2121. 3301. 3469.
65 1060. 1606. 1246.
75 107. 190. 240.
85 19. 19. 19.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 89 85 83 80 78 76 77 75 74
2 81 76 71 71 68 64 69 66 63
3 74 67 61 63 59 55 61 57 54
4 68 59 53 56 51 47 55 50 46
5 63 53 46 50 45 40 49 44 40
6 58 48 41 45 40 35 44 39 35
7 53 43 36 41 35 31 40 35 31
8 50 39 32 37 32 28 36 31 27
9 46 36 29 34 29 25 33 28 25
10 43 33 27 32 26 22 31 26 22
ZONE LUMENS % LAMP % FIXT
00-030 1277 22.4 28.0
00-040 2165 38.0 47.5
00-060 4161 73.0 91.2
00-090 4561 80.0 100.0
90-180 0000 0.0 000.0
00-180 4561 80.0 100.0
ZONAL LUMEN SUMMARY
Mounting Height
Lengthwise Crosswise
Room Luminaires Luminaires
Size 0 Deg Plane 90 Deg Plane
8.5 10 13 16 8.5 10 13 16
30x30 86 81 75 73 84 77 71 71
40x40 86 85 80 74 84 81 76 71
60x30 86 84 79 75 84 79 76 74
60x60 86 85 84 78 84 80 80 75
100x100 86 85 84 81 84 80 80 77
TYPICAL V.C.P.'s
0.0 45.0 90.0 FLUX
0 2502 2502 2502
5 2497 2501 2500 239
15 2395 2482 2549 702
25 2213 2422 2674 1128
35 1966 2388 2741 1484
45 1647 2183 2047 1541
55 1202 1300 970 1062
65 483 419 384 444
75 23 25 20 31
85 3335
90 000
Model No. ICS2G18LS33212003
LER = FP - 68.8 IW - 85.8 BF - 0.89
Comparative yearly lighting energy cost per
1000 lumens = 3.49
Report Number: ITL49576
Catalog Number: ICS2G18LS33212003
Lamp: (3) F32 T8
Luminaire: IC 2' X 4' Troffer with 3X6
Semi-Specular Louver
Ballast: M3-RN-T81LL-120
Report is based on 2850 Lumens per lamp.
Efficiency: 77.6%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.6
Shielding Angles: 18 38
Plane: 0-Deg 90-Deg
Luminous Length: 45.125 21.000
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3808. 5048. 4733.
55 3427. 3706. 2765.
65 1869. 1621. 1486.
75 145. 158. 126.
85 56. 56. 56.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 86 83 81 78 76 75 75 74 72
2 80 74 70 70 67 64 68 65 62
3 73 66 61 63 58 55 61 57 54
4 67 59 53 56 51 47 54 50 47
5 62 53 47 51 45 41 49 45 41
6 57 48 41 46 40 36 45 40 36
7 53 43 37 42 36 32 41 36 32
8 50 40 33 38 33 29 37 32 29
9 46 36 30 35 30 26 34 29 26
10 43 33 28 32 27 23 32 27 23
ZONE LUMENS % LAMP % FIXT
00-030 2068 24.2 31.2
00-040 3552 41.5 53.5
00-060 6155 72.0 92.8
00-090 6634 77.6 100.0
90-180 0000 0.0 000.0
00-180 6634 77.6 100.0
ZONAL LUMEN SUMMARY
Mounting Height
Lengthwise Crosswise
Room Luminaires Luminaires
Size 0 Deg Plane 90 Deg Plane
8.5 10 13 16 8.5 10 13 16
30x30 83 77 69 65 85 80 74 69
40x40 85 80 76 68 85 82 79 71
60x30 83 78 74 69 85 81 78 71
60x60 85 81 81 73 85 82 83 76
100x100 85 81 81 75 85 82 83 77
TYPICAL V.C.P.'s
Options:
Lamps
Flex
EM Pack
Fuse
(Consult your
representative)
-
Job Information Type:
For Factory Technical Information: (97 ) 657-7600 • Fax (97 ) 65 -0595 0 /10
631 Airport Road, Fall River, MA 02720 • (50 ) 679- 131 • Fax (50 ) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group Section 7/Folio Q80-25 Rev. A

Other Lightolier Lighting Equipment manuals

Lightolier Baselyte-BSL31 User manual

Lightolier

Lightolier Baselyte-BSL31 User manual

Lightolier EC1-11 User manual

Lightolier

Lightolier EC1-11 User manual

Lightolier Lighting Systems LFK1 User manual

Lightolier

Lightolier Lighting Systems LFK1 User manual

Lightolier Covelite CL-3 User manual

Lightolier

Lightolier Covelite CL-3 User manual

Lightolier Lighting Systems EC2-4 User manual

Lightolier

Lightolier Lighting Systems EC2-4 User manual

Lightolier RT6-6 User manual

Lightolier

Lightolier RT6-6 User manual

Lightolier 1101FIC User manual

Lightolier

Lightolier 1101FIC User manual

Lightolier LSBW-2 User manual

Lightolier

Lightolier LSBW-2 User manual

Lightolier IS-SIL_J User manual

Lightolier

Lightolier IS-SIL_J User manual

Lightolier Lytespan 83ED17RF User manual

Lightolier

Lightolier Lytespan 83ED17RF User manual

Lightolier Lytespan 8620WH User manual

Lightolier

Lightolier Lytespan 8620WH User manual

Lightolier TCU Series User manual

Lightolier

Lightolier TCU Series User manual

Lightolier Lighting Systems Baselyte-BSL25 User manual

Lightolier

Lightolier Lighting Systems Baselyte-BSL25 User manual

Lightolier Lytespan 8114 User manual

Lightolier

Lightolier Lytespan 8114 User manual

Lightolier PRE-WIRED COMPACT FLUORESCENT EMERGENCY... Guide

Lightolier

Lightolier PRE-WIRED COMPACT FLUORESCENT EMERGENCY... Guide

Lightolier LTC Series User manual

Lightolier

Lightolier LTC Series User manual

Lightolier IS_ST624 User manual

Lightolier

Lightolier IS_ST624 User manual

Lightolier Lightolier LP-11 User manual

Lightolier

Lightolier Lightolier LP-11 User manual

Lightolier Calculite ProSpec PA1P3810 User manual

Lightolier

Lightolier Calculite ProSpec PA1P3810 User manual

Lightolier Lytecaster 315X User manual

Lightolier

Lightolier Lytecaster 315X User manual

Lightolier HDB2SLW128 User manual

Lightolier

Lightolier HDB2SLW128 User manual

Lightolier Lytespan 7610 User manual

Lightolier

Lightolier Lytespan 7610 User manual

Lightolier LSBW-6 User manual

Lightolier

Lightolier LSBW-6 User manual

Lightolier Calculite C6AW User manual

Lightolier

Lightolier Calculite C6AW User manual

Popular Lighting Equipment manuals by other brands

LIGHTSAFE EDLED quick start guide

LIGHTSAFE

LIGHTSAFE EDLED quick start guide

Blizzard Lighting Pocket Nebula user guide

Blizzard Lighting

Blizzard Lighting Pocket Nebula user guide

Flash WashFX 1000 IP65 user manual

Flash

Flash WashFX 1000 IP65 user manual

UFO MicroLED 4000P Product user guide

UFO

UFO MicroLED 4000P Product user guide

JONATHAN Y JYL3019A-B Install

JONATHAN Y

JONATHAN Y JYL3019A-B Install

Star Headlight & Lantern ULB34 quick start guide

Star Headlight & Lantern

Star Headlight & Lantern ULB34 quick start guide

Twinkly curtain Instruction guide

Twinkly

Twinkly curtain Instruction guide

GE 23071LO instructions

GE

GE 23071LO instructions

Good Earth Lighting AC1358-RGB-06LF0-G manual

Good Earth Lighting

Good Earth Lighting AC1358-RGB-06LF0-G manual

ACME COMET user manual

ACME

ACME COMET user manual

DL diode led installation guide

DL

DL diode led installation guide

Hella 2RL 008 061-001 Mounting instructions

Hella

Hella 2RL 008 061-001 Mounting instructions

Astera Lightdrop AX3 user manual

Astera

Astera Lightdrop AX3 user manual

Kogan NBOTLTUBBPA user guide

Kogan

Kogan NBOTLTUBBPA user guide

Hubbell KIM LIGHTING VRB1 installation instructions

Hubbell

Hubbell KIM LIGHTING VRB1 installation instructions

LANZINI EVO XL TORREFARO instructions

LANZINI

LANZINI EVO XL TORREFARO instructions

ACME HYGIEA user manual

ACME

ACME HYGIEA user manual

Larson Electronics WAL-HL-2000W-240V instruction manual

Larson Electronics

Larson Electronics WAL-HL-2000W-240V instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.