4.1.2 When put batteries in the charger, the charger will test the inner resistance of batteries about 3 seconds, and
then automatically under choosing current mode, LCD display will flash with “500mah” for 8 seconds, during those
8 seconds, you can choose 500ma or 1000mah through mode button to charge batteries, the system will lock the
current you choose and charge after 8 seconds. If there is no choosing current within 8 seconds, the system will
automatically charge batteries with 500ma, and it could not be changed at this time. If you want to change the
charging current, you must replace the batteries.
4.1.3 Users should be pay attention to the biggest charging current, if there is no need to
quick charge, it would be better to charge with 500ma, which is the safest and the
most favorable to batteries.
4.1.4 Under charge mode, you can slightly press mode button and shift to check 4 units:
charging capacity(mah)/charging time(h)/battery internal resistance(mR)/charging
current(mA). After full charge of batteries, it will show Full and charge End in small size at the bottom line on the
LCD display.
4.2 Discharge Mode
4.2.1 Discharge mode: Fully charge batteries first, and then discharge batteries to record discharging current and test
battery capacity, after that the batteries will be fully charged.
4.2.2 After the charger test the inner resistance of batteries, Long press mode button for 3
seconds to enter discharge mode under any circumstances;
-after entering discharge mode, the display will flash with“500ma”for 8 seconds, at
the same time, you can choose 500ma or 1000ma through mode button. The System will lock the current you choose
after 8 seconds, if there is no selection of current within 8 seconds, then the system will automatically charge battery
with 500ma(the current you choose is the current for charging batteries.)
-when the batteries are fully charged, the system will
automatically discharge batteries with 500ma and record discharge current and test battery capacity. When the LCD
show discharge end, capacity test mode is over, and
the current parameter flashing on the LCD is the actual capacity of batteries.
-after capacity test, the battery charger will charge batteries with the current chosen before
until the batteries are fully charged.
5. USB 5V Boost output
5.1 USB output is boost output only, output current is 1000mA, it is not available when connecting the power.
5.2 USB output will charge the 5V electronic devices when put the batteries in the charger slots.
5.3 Charger have two battery slots, any of one slot can do USB 5V boost output, we advise two batteries are put in
two slots at the same time.
5.4 Only 3.7V li-ion battery can support the USB 5V Boost output function. NI-MH battery is not available.
6. Specific Parameters
6.1 DC Input:12V/1.5A
6.2 Charge current for li-ion battery:2*(4.2V 500mA),2*(4.2V 1000mA)
Fully charge
battery
again