Symptom Remedy
System is powered, but will
not initialise.
1. Try pressing and releasing the DOWN button a few times before
pressing and holding for 5 seconds.
2. Also, be aware if the control box has a special configuration:
If the desk is programmed with a lower stroke limit, so as to
avoid a collision with something like a file cabinet, it is possible
that it also has a custom, longer Forced Initialisation Time. This
is the time required to hold DOWN before initialisation begins.
Sometimes this is 10 seconds or longer.
3. If you have a standard control box without a special
configuration (i.e. with standard configuration), try to initialise
each column in Channel 1 by itself, with nothing else plugged
into the motor channels on the control box. Also, swap the
motor cables so that a different motor cable is used to initialise
Channel 1 by itself. The problem could be a faulty column or a
faulty motor cable.
Channel-specific error
E.g. E41 – Channel 1 overload
(Everything except PIEZO
errors
E59-E63)
1. Swap the motor cable connections at the control box (motor
cable #1 from channel 1 to 2, motor cable #2 from channel
2 to 1). If it remains E41, there could be a problem with the
application (load or obstruction on one side) or a defective
control box. If the error changes to E42, go to step 2.
2. Swap the motor cable connections at the columns, so that the
column that was originally connected to Channel 1 is back
in Channel 1, but with the motor cable that was originally
connected to Channel 2. If it remains E42, it is most likely a
defective motor cable, now connected to Channel 2. If it goes
back to E41, it is most likely a defective column, now connected
to Channel 1.
Desk is uneven 1. Initialise the desk. If both columns begin to run down, complete
the initialisation. If only one column moves, stop and go to Step
2.
2. Check motor cable connections. Check to ensure motor cables
are not pulled during movement. With a standard control box, it
is possible that only one column is connected, and connected to
Channel 1. In this case, it will initialise and run Channel 1 only. If
there is only one column but it is connected to Channel 2, it will
not initialise.
3. If a motor cable was disconnected, reconnect the cable and try
initialising again.
4. If unsuccessful, connect the column from Channel 2 into
Channel 1, with nothing in Channel 2, and initialise.
5. Try initialising the same column that is in Channel 1, but with
a different motor cable. If it still will not initialise, replace the
column.