Linear’s AccessKey is a digital keyless entry system
designed for access control applications. The keypad is
housed in a rugged cast aluminum enclosure that can be
mounted to a pedestal or bolted directly to a wall. The
die-cast keys have bright, easy-to-read yellow graphics.
Up to 480 entry codes, from 1 to 6 digits in length, can be
programmed. They can activate either, or both, of the relay
outputs. Relay #1 has a 5 Amp capacity. Relay #2 has a
1 Amp capacity.
Two LED indicators show the status of the entry system.
The left LED lights red to indicate power, then turns green
when access is granted. The right LED lights yellow when
the keypad is in “lockout” condition (from too many
incorrect code entries). The keypad’s courtesy light
illuminates the keys for two minutes after any key is pressed.
An internal sounder beeps when each key is pressed.
The DOOR SENSE/INHIBIT input can be used two ways.
If programmed for “door sense”, a switch on the door
detects forced entry or door ajar situations. If programmed
for “inhibit”, the input can be wired to a “service” switch or
automatic timer that will disable the Relay #1 when
required.
The REQUEST-TO-ENTER input can be wired to a
pushbutton or fire access keyswitch to provide codeless
entry for authorized personnel. The “anti-passback”
feature prevents using the same code twice before the
programmed time elapses.
The ALARM SHUNT output activates when access is
granted. This output can be wired to shunt alarm contacts
on the access door/gate to prevent triggering of an alarm
when authorized access occurs.
Two solid state outputs, capable of switching 100 mA to
common, are programmable to signal forced entry, door
ajar, lockout, alarm circuit shunting, request-to-enter, and
keypad active conditions.
The AccessKey is powered from a 12-24 Volt AC or DC
source. Power can be obtained from the access device or
a separate power supply. The EEPROM memory retains
all entry codes and programming, even without power.
SPECIFICATIONS
MECHANICAL
Case dimensions: 4.00" W x 5.50" H x 3.00" D
ELECTRICAL
Voltage: 12-24 Volts AC or DC
Current: 10 mA typical, 150 mA maximum
Outputs: Relay #1
Form “C” 5 Amps @ 24 Volts maximum
Relay #2
Form “C” 1 Amp @ 24 Volts maximum
Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA
@ 24 VDC maximum
ENVIRONMENTAL
Temperature: -22°F to 149°F (-30°C to 65°C)
Humidity: 5% to 95% non-condensing
FEATURES
KEYPAD PROGRAMMABLE
480 ENTRY CODE CAPACITY
1-6 DIGIT ENTRY CODE LENGTH
4 INDEPENDENT OUTPUTS (TIMED/TOGGLED)
4 INDEPENDENT TIMERS
EACH ENTRY CODE CAN BE PROGRAMMED TO ACTIVATE EITHER OR
BOTH RELAYS
RELAY CONTACTS ARE FORM “C” (N.O. & N.C)
SOLID STATE OUTPUTS ARE OPEN COLLECTOR (SWITCH-TO-COMMON)
TWO LED INDICATORS
COURTESY LAMP
PIEZO SOUNDER
TIMED ANTI-PASSBACK (LAST 3 VALID ENTRIES)
KEYPAD LOCKOUT
TACTILE KEY FEEL
DOOR SENSE INPUT
INHIBIT INPUT
REQUEST-TO-ENTER INPUT
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
COMPONENT LOCATIONS . . . . . . . . . . . . . . . . . . . . . . 3
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . 3
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
FACTORY DEFAULTS . . . . . . . . . . . . . . . . . . . . . . . . . 6
BASIC PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . 6
PROGRAMMING OPTIONS . . . . . . . . . . . . . . . . . . . . . 7
ACCESSKEY OPERATION . . . . . . . . . . . . . . . . . . . . . . 10
MANAGER’S ENTRY CODE LOG . . . . . . . . . . . . . . . . . . 11
LINEAR LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . 12
FCC NOTICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2

Black 0003
Black0003
COMPONENT LOCATIONS
WIRING DIAGRAM
TACTILE
KEYPAD
YELLOW
"LOCKOUT"
INDICATOR
RED/GREEN
POWER/ACCESS
INDICATOR
NIGHT
LIGHT
TERMINAL BLOCK J4
POWER AND INPUTS KEYLOCK
TERMINAL
BLOCK J3
OUTPUTS
JUMPER JP1
REMOVE TO
REDUCE
BEEPER SOUND
JUMPER JP2
RESETS
MASTER CODE
Figure 1. Component Locations
J4
1
2
3
4
5
6
J3
1
2
3
4
5
6
7
8
9
POWER
INHIBIT
COMMON
REQUEST-TO-ENTER
EARTH GROUND
N.O.
COMMON
N.C.
OUTPUT #3
OUTPUT #4
N.O.
COMMON
N.C.
COMMON
GROUND
ACCESSKEY
GATE OPERATOR
INHIBIT
TIMER
AUXILIARY
POWER
OPEN
J4
1
2
3
4
5
6
J3
1
2
3
4
5
6
7
8
9
DOOR SENSE
COMMON
REQUEST-TO-ENTER
EARTH GROUND
N.O.
COMMON
N.C.
OUTPUT #3
OUTPUT #4
N.O.
COMMON
N.C.
COMMON
GROUND
ACCESSKEY
FIRE
ACCESS ELECTRIC
DOOR
STRIKE
OPEN
DOOR SWITCH
ALARM CONTACT
OPTIONAL WIRING
REQUIRED WIRING
POWER
SUPPLY
RELAY #1
TO ALARM
SYSTEM
TO ALARM
SYSTEM
POWER
RELAY #2
RELAY #1
RELAY #2
TYPICAL DOOR INSTALLATION WIRINGTYPICAL GATE INSTALLATION WIRING
Figure 2. Wiring Diagram
3

Black 0004
Black0004
INSTALLATION
To avoid damage to the unit from static discharges,
connect the EARTH GROUND terminal to a good earth
grounding point. Suggested wiring size is 18 AWG for earth
ground and power (up to 500 feet of 18 AWG wire can be
run for power, use larger wire for longer runs). Use
22 AWG or larger (depending on the load) for all other
connections.
!CAUTION: If the unit is AC powered, and one
side of the power transformer secondary is
connected to earth ground, connect the
grounded side to the “-” power terminal of the
unit.
Select a location for the keypad. For door access control
installations, mount the keypad near the controlled door.
For gate control installations, mount the keypad in clear
view of the gate, but far enough from the gate so the user
cannot touch the gate from the keypad.
#WARNING: TO AVOID SERIOUS INJURY OR
DEATH, MAKE SURE THAT THE UNIT IS FAR
ENOUGH FROM THE GATE SO THAT THE USER
CANNOT TOUCH THE GATE WHILE OPERATING
THE KEYPAD. HOWEVER, THE GATE MUST BE
FULLY VISIBLE FROM THE KEYPAD.
Pedestal Mounting
The AccessKey keypad can be mounted on a standard
pedestal.
Use four security bolts and locking nuts to secure the
keypad’s backplate to the pedestal (see Figure 3).
Wall Mounting
The AccessKey keypad can be mounted directly to a wall
or flat surface.
Use the appropriate fasteners to secure the keypad’s
backplate to the mounting surface.
When mounting the keypad to a concrete wall, use
concrete wedge anchors or molly anchors (see
Figure 4).
PEDESTAL
MOUNT BACKPLATE WITH
SECURITY BOLTS AND LOCKNUTS
Figure 3. Pedestal Mounting Keypad Backplate
USE CONCRETE
WEDGE ANCHORS
OR MOLLY ANCHORS
WALL MOUNTING
Figure 4. Wall Mounting Keypad Backplate
4

Black 0005
Black0005
Gate Control
Route four wires between the gate and the keypad (two
for power, two for control).
Connect the gate operator’s auxiliary or radio power
output terminals to the keypads POWER input
terminals (observe wiring polarity).
Connect the gate operator’s OPEN terminals to the
keypad’s Relay #1 COMMON & N.O. terminals.
NOTE: For operator wiring specifics, refer to the
gate operator’s wiring diagram.
If a request-to-enter pushbutton or fire access
keyswitch is going to be used, route two wires from the
keypad to the normally open switch. Connect the wires
to the normally open switch and to the keypad’s
REQUEST-TO-ENTER and COMMON terminals.
If an inhibit switch or timer is going to be used, route
two wires from the keypad to the inhibit switch or timer
relay. Connect the inhibit switch/timer terminals to the
keypad’s INHIBIT and COMMON terminals.
NOTE: If the INHIBIT input is going to be used, it
must be programmed to select that input type. See
the Programming Options section of this manual.
Door Control
Install a low voltage electric door strike for unlocking
the door.
Choose a location for the power supply or transformer.
Route two wires between the power supply and the
keypad. Connect the power supply’s output terminals
to the keypads POWER input terminals (observe wiring
polarity).
Route two wires between the door strike and the
keypad. Connect one of the door strike wires to the
keypad’s Relay #1 N.O. terminal. Connect the other
door strike wire to the keypad’s POWER +terminal.
Connect a wire between the keypad’s POWER -
terminal and the Relay #1 COMMON terminal.
If a request-to-enter pushbutton or fire access
keyswitch is going to be used, route two wires from the
keypad to the normally open switch. Connect the wires
to the normally open switch and to the keypad’s
REQUEST-TO-ENTER and COMMON terminals.
To use the door sense feature to detect forced entry or
door ajar conditions, install a normally closed door
switch on the door and route two wires from the switch
to the keypad. Connect the door switch to the keypad’s
DOOR SENSE and COMMON terminals.
If an inhibit switch or timer is going to be used, route
two wires from the switch or timer to the keypad.
Connect the inhibit switch/timer terminals to the
keypad’s INHIBIT and COMMON terminals.
NOTE: Either door sense or inhibit can be used.
Both features cannot be used at the same time.
ACCESSKEY
KEYPAD
FIRE
ACCESS
KEYSWITCH
2 WIRES FROM OPERATOR
FOR ACCESSKEY POWER
GATE
OPERATOR
(BEHIND GATE)
2 WIRES FROM ACCESSKEY
TO TRIGGER GATE OPEN
2 WIRES FOR
REQUEST-TO-ENTER
Figure 5. Gate Installation
FROM
POWER
SUPPLY
DOOR
SENSE
SWITCH
ELECTRIC
DOOR
STRIKE
ACCESSKEY
KEYPAD
2 WIRES
FOR DOOR
STRIKE
2 WIRES
FOR DOOR
SENSE
2 WIRES
FOR
POWER
Figure 6. Door Installation
5

Black 0006
Black0006
FACTORY DEFAULTS
MASTER PROGRAMMING CODE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123456
ENTRY CODE LENGTH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 DIGITS
REQUEST-TO-ENTER OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RELAY #1
ALARM SHUNT OUTPUT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISABLED
FORCED ENTRY OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OUTPUT #3
DOOR AJAR OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OUTPUT #4
RELAY #1 ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SECONDS
RELAY #2 ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SECONDS
SOLID STATE OUTPUT #3 ON TIME. . . . . . . . . . . . . . . . . . . . . . . . . 2 SECONDS
SOLID STATE OUTPUT #4 ON TIME. . . . . . . . . . . . . . . . . . . . . . . . . 2 SECONDS
DOOR SENSE/INHIBIT INPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . DOOR SENSE
KEYPAD LOCKOUT OUTPUT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISABLED
KEYPAD ACTIVE OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISABLED
BEEPER SOUNDS WHEN KEY PRESSED . . . . . . . . . . . . . . . . . . . . . . . . . . . . YES
BEEPER SOUNDS DURING RELAY #1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO
BEEPER SOUNDS DURING RELAY #2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO
BEEPER SOUNDS DURING OUTPUT #3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO
BEEPER SOUNDS DURING OUTPUT #4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO
KEYPAD LOCKOUT COUNT . . . . . . . . . . . . . . . . . . . . 3 TRIES BEFORE LOCKOUT
ANTI-PASSBACK TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO ANTI-PASSBACK
BASIC PROGRAMMING
When the AccessKey is in programming mode, both LEDs
will turn off until programming begins. After a programming
option number is entered the yellow LED will blink. This
indicates that the AccessKey is ready to accept the new
programming data. After the new data entry is complete,
the green LED will light while the data is being stored. The
red LED will light if any programming data is entered
incorrectly, and the command will have to be fully re-entered.
Entering Programming Mode
The 6-digit Master Programming Code (default = 123456)
is used to enter Programming Mode.
Press: #9 #Master Code
Master Code = the current 6-digit Master Programming Code
Exiting Programming Mode
Press: **#
The red LED will light when Programming Mode is exited.
NOTE: The Accesskey will automatically exit
Programming Mode after two minutes of inactivity.
Re-entering a Command After a Mistake
If the red LED lights, indicating an incorrect entry, or a
wrong key is pressed during programming, to clear the
keypad and re-enter the command:
Press: *9 #
Setting Entry Code Length Default: 4 digits
Press: 0 3 #Length #
Length = 1 - 6 for entry code length
NOTE: If the Entry Code Length is going to be
changed from the factory default of four digits, make
this change first, before programming any entry
codes.
Adding a New Entry Code
Press: 0 1 #Code #Code #Relay #
Code = The new entry code:
1-999999, depending on code length
Relay = Relay output entry code will activate:
1 = Relay #1 2 = Relay #2
3 = Both Relays
The yellow LED will flash quickly while the AccessKey
searches its memory for available space and duplicate
entries. The green LED will light when the new code is
stored.
If the new entry code chosen is already being used for
another entry code, the red LED will light. A new unique
code needs to be entered.
NOTE: Leading zeros (zeros before the code
number, i.e. 0001) do not need to be entered when
programming a new entry code. The AccessKey will
internally add any zeros to fill all digits determined
by the entry code length setting. Leading zeros will
have to be entered by the user when entering their
code to gain access.
Erasing a Single Entry Code
Press: 0 2 #Code #Code #
Code = The entry code to delete.
The yellow LED will flash quickly while the AccessKey
searches its memory for the code to erase. The green LED
will light when the code is erased.
Erasing All Entry Codes
#WARNING: Performing this command will
remove all entry codes from the memory.
Press: 9 7 #0 0 0 0 0 0 #0 0 0 0 0 0 #
NOTE: The green LED will light while the memory is
being erased. This may take up to 15 seconds.
Changing the 6-Digit Master Programming Code
Press: 9 8 #Master Code #Master Code #
Master Code = The new 6-digit Master Programming Code
New master code: _____________________
6

Black 0007
Black0007
PROGRAMMING OPTIONS
There are several AccessKey programming options. For
most installations, the factory set default options are
sufficient. The keypad must be in programming mode
to make these changes.
Programming Accesskey to Hold the Output
Linear’s AccessKey products have a programmable
“Toggle Mode” available for each relay and solid-state
output. When an output is programmed for Toggle Mode,
the output alternates from OFF to ON or from ON to OFF
each time it is activated.
The rules for a toggle output are:
If the output is OFF, it will turn ON and stay on until
the next activation.
If the output is ON, it will turn OFF and stay off until
the next activation.
Typical Programming
With the unit in Program Mode, set the Auxiliary Relay (Relay
#2) output to Toggle Mode using the following keystrokes:
Press: 2 2 # 9 9 #
22= Programming Step; 99 = Toggle Mode
Program all normal entry codes to use the Main Relay
(Relay #1), and only Relay #1 as the output relay. Program
the code(s) that you want to use to gold the output for an
indefinite period to the Auxiliary Relay (Relay #2). See the
following example that sets entry codes 1234 for normal
and 5678 for toggle operation.
Press: 0 1 # 1 2 3 4 # 1 2 3 4 # 1 #
01 = Programming Step; 1234 = Entry Code;
1 = Main Relay
Press: 0 1 # 5 6 7 8 # 5 6 7 8 # 2 #
01 = Programming Step; 5678 = Entry Code;
2 = Auxiliary Relay
Typical Wiring
For devices triggered by a normally open circuit, wire the
contacts of the Main and Auxiliary Relays in parallel (see
the Figure below). Either relay will be able to trigger the
access device. Entry codes programmed for the Auxiliary
Relay will be able to hold the output on.
Select Door Sense or Inhibit Input
Default: Door Sense
The input on terminal block J4, terminal #3 can be
programmed for DOOR SENSE or INHIBIT.
Press: 1 0 #Input#
Input = 1 for Inhibit,
= 0 for Door Sense
When programmed for DOOR SENSE, if an open condition
on the input occurs before access is granted (with an entry
code or with the request-to-enter input) a FORCED
ENTRY output will occur. If an open condition remains
60 seconds after a relay activation for access, a DOOR
AJAR output will occur.
When programmed for INHIBIT, a closed condition on the
input will prevent relay #1 from activating when access is
requested (with an entry code). This mode is typically used
with an external timer to disable the access device at
certain times.
Select Forced Entry Output Default: Output #3
Sets which output activates if the Door Sense input opens before
access is granted. This output is not timed.
Press: 1 1 #Output #
Output = Output to Activate (0-4)
1 = Relay #1 2 = Relay #2 3 = Output #3
4 = Output #4 0 = No Output
Select Door Ajar Output Default: Output #4
Sets which output activates if the Door Sense input stays open after
access is granted. This output is not timed.
Press: 1 2 #Output #
Output = Output to Activate (0-4)
1 = Relay #1 2 = Relay #2 3 = Output #3
4 = Output #4 0 = No Output
Select Keypad Lockout Output Default: No Output
Sets which output activates when the keypad is “locked out” after too
many incorrect entry code attempts. The lockout time is 60 seconds.
Press: 1 3 #Output #
Output = Output to Activate (0-4)
1 = Relay #1 2 = Relay #2 3 = Output #3
4 = Output #4 0 = No Output
Select Keypad Active Output Default: No Output
Sets which output activates when any keys are pressed. This output
is timed. If toggle mode is selected, the timer value defaults to 2
seconds.
Press: 1 4 #Output #
Output = Output to Activate (0-4)
1 = Relay #1 2 = Relay #2 3 = Output #3
4 = Output #4 0 = No Output
Select Alarm Shunt Output Default: No Output
Sets which output activates during the time access is granted. (Use
this output to shunt alarm contacts attached to the access door.) This
output may be timed or latched.
Press: 1 5 #Output #
Output = Output to Activate (0-4)
1 = Relay #1 2 = Relay #2 3 = Output #3,
4 = Output #4 0 = No Output
1234
NORMAL
ENTRY CODE
5678
TOGGLE
ENTRY CODE
N.O.
COMMON
N.C.
N.O.
COMMON
N.C.
MAIN
RELAY
AUXILIARY
RELAY
ACCESSKEY
OUTPUTS
ACCESS
DEVICE
EITHER RELAY CAN TRIGGER
THE ACCESS DEVICE
7

Black 0008
Black0008
Select Request-to-Enter Output Default: Relay #1
Sets which output activates when the Request-to-Enter input is
grounded. This output may be timed or toggled.
Press: 1 6 #Output #
Output = Output to Activate (0-4)
1 = Relay #1 2 = Relay #2 3 = Output #3
4 = Output #4 0 = No Output
Relay #1 On-time Default: 2 Seconds
Sets the length of time Relay #1 activates when triggered.
Press: 2 1 #Seconds #
Seconds = Output time in seconds (0-60)
99 = Toggle mode
Relay #2 On-time Default: 2 Seconds
Sets the length of time Relay #2 activates when triggered.
Press: 2 2 #Seconds #
Seconds = Output time in seconds (0-60)
99 = Toggle mode
Solid-state Output #3 On-time Default: 2 Seconds
Sets the length of time Output #3 activates when triggered.
Press: 2 3 #Seconds #
Seconds = Output time in seconds (0-60)
99 = Toggle mode
Solid-state Output #4 On-time Default: 2 Seconds
Sets the length of time Output #4 activates when triggered.
Press: 2 4 #Seconds #
Seconds = Output time in seconds (0-60)
99 = Toggle mode
Beep Sounds on Keystrokes Default: Yes
Selects whether or not the keypad beeps as each key is pressed.
Press: 4 0 #Sound #
Sound = 1 for Yes
= 0 for No
Beep Sounds During Relay #1 Default: No
Selects whether or not the keypad beeps during Relay #1 activation.
Press: 4 1 #Sound #
Sound = 1 for Yes
= 0 for No
Beep Sounds During Relay #2 Default: No
Selects whether or not the keypad beeps during Relay #2 activation.
Press: 4 2 #Sound #
Sound = 1 for Yes
= 0 for No
Beep Sounds During Output #3 Default: No
Selects whether or not the keypad beeps during Output #3 activation.
Press: 4 3 #Sound #
Sound = 1 for Yes
= 0 for No
Beep Sounds During Output #4 Default: No
Selects whether or not the keypad beeps during Output #4 activation.
Press: 4 4 #Sound #
Sound = 1 for Yes
= 0 for No
Keypad Lockout Count Default: 3 Tries
Sets the number of incorrect entry code attempts allowed before the
keypad “locks out”.
Press: 5 0 #Attempts #
Attempts = Number of attempts before lockout (2-7)
Anti-passback Time Default: No Anti-passback
Sets the length of time an entry code will not function after it is used.
Press: 5 1 #Minutes #
Minutes = Time in Minutes (1-4)
0 = No Anti-passback
Master Reset
!CAUTION: Performing a master reset will clear
the entire memory of the AccessKey and return
all programmable options to the factory default
values. ALL ENTRY CODES WILL BE ERASED.
STEP 1 Disconnect power from the keypad.
STEP 2 Press and hold down the *and #keys.
STEP 3 Apply power to the keypad, continue holding the
keys down until the red LED starts flashing.
STEP 4 Release the keys. The red and yellow LEDs will
remain lit until the process is complete, then the
yellow LED will go out.
Resetting the Master Code
STEP 1 Open the AccessKey case.
STEP 2 Locate jumper JP2. This jumper is used to reset
the master code.
STEP 3 With power applied to the keypad, remove jumper
JP2. The keypad will begin to beep, signaling that
the code has been reset.
STEP 4 Replace jumper JP2.
THE MASTER PROGRAMMING CODE IS NOW 123456.
8

Black 0009
Black0009
Solid State Outputs
The two solid state outputs (Output #3 & Output #4) can
be programmed to activate during various conditions.
These outputs can be used to activate indicators or
sounders. See Figure 7 for wiring examples using the solid
state outputs.
Beeper Sound Level
The keypad’s beeper can be set to low or high level.
If the keypad’s beeper is too loud for the keypad’s
location, remove jumper JP1 (see Figure 8).
Locking Keypad
After the installation is complete. Lock the keypad using
the keylock (see Figure 9).
REMOVE JUMPER JP1 TO REDUCE
THE SOUND LEVEL OF THE BEEPER
Figure 8. Removing Beeper Jumper
HOOK KEYPAD
ONTO BACKPLATE
USE KEY TO
LOCK KEYPAD
Figure 9. Locking the Keypad Case
OUTPUT #3
OUTPUT #4
COMMON
GROUND
ACCESSKEY
POWER
1K
Ω
LED
1K
Ω
LED
ELECTRONIC
BEEPER
EXAMPLE 1: OUTPUT #3 LIGHTS AN LED,
OUTPUT #4 LIGHTS AN LED AND SOUNDS A BEEPER
EXAMPLE 2: OUTPUT #3 LIGHTS A LAMP POWERED FROM AN EXTERNAL
SOURCE, OUTPUT #4 TRIGGERS A NORMALLY OPEN ALARM PANEL ZONE
OUTPUT #3
OUTPUT #4
EACH
OUTPUT
100 mA
MAXIMUM
ALARM PANEL
N.O. ZONE
COMMON
END-OF-LINE
RESISTOR
POWER
SOURCE
LOW VOLTAGE
LAMP
EACH
OUTPUT
100 mA
MAXIMUM
Figure 7. Using the Solid State Outputs
9

Black 0010
Black0010
ACCESSKEY OPERATION
Users of the AccessKey have up to 40 seconds to
key in their entry code.
Up to eight seconds are allowed between each
keystroke.
All digits of the entry code must be entered.
Example: If the code is 0042, the user must enter
“0 0 4 2”.
If the wrong key is pressed, pressing the *key
will reset the keypad. The correct code can then be
re-entered.
After a correct code is entered, the red LED will
turn green and the programmed relay will activate
for the programmed time.
If the number of incorrect codes entered exceeds
the keypad lockout count, the yellow LED will light,
indicating that the keypad is locked out. The
lockout will remain for one minute.
After a valid code has been entered, it will be
unusable until the anti-passback time expires.
USERS HAVE UP TO
40 SECONDS TO ENTER
THEIR COMPLETE CODE
PRESS STAR KEY TO
RESET KEYPAD IF THE
WRONG KEY IS PRESSED
RED LED TURNS
GREEN WHEN
ACCESS IS GRANTED
YELLOW LED WILL LIGHT
DURING KEYPAD LOCKOUT IF
TOO MANY INCORRECT CODES
ARE ENTERED
Figure 10. Operating AccessKey
10

Black 0011
Black0011
MANAGER’S ENTRY CODE LOG
NAME ADDRESS OR APARTMENT NUMBER ENTRY CODE RELAY NUMBER
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
◊1 ◊2
11

Black 0012
Black0012
LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in
material and workmanship for twelve (12) months. The
Warranty Expiration Date is labeled on the product. This
warranty extends only to wholesale customers who
buy direct from Linear or through Linear’s normal
distribution channels. Linear does not warrant this
product to consumers. Consumers should inquire from
their selling dealer as to the nature of the dealer’s warranty,
if any. There are no obligations or liabilities on the part
of Linear corporation for consequential damages arising
out of or in connection with use or performance of this
product or other indirect damages with respect to loss
of property, revenue, or profit, or cost of removal,
installation, or reinstallation. All implied warranties,
including implied warranties for merchantability and implied
warranties for fitness, are valid only until Warranty Expiration
Date as labeled on the product. This Linear Corporation
Warranty is in lieu of all other warranties express or
implied.
All products returned for warranty service require a Return
Product Authorization Number (RPA#). Contact Linear
Technical Services at 1-800-421-1587 for an RPA# and
other important details.
FCC NOTICE
Changes or modifications not expressly described in this
manual or approved by the manufacturer could void the
user’s authority to operate the equipment.
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception, which
can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by
one or more of the following measures:
° Reorient or relocate the receiving antenna.
° Increase the separation between the equipment and
receiver.
° Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
° Consult the dealer or an experienced radio/TV
technician for help.
Copyright © 2002 Linear Corporation 214530 E
Table of contents
Other Linear Remote Starter manuals

Linear
Linear Digital Keyless Entry System AK-3 Technical specifications

Linear
Linear AKR-1 Technical specifications

Linear
Linear ACCESS AK-21 Technical specifications

Linear
Linear AE-2000 User manual

Linear
Linear Digital Keyless Entry System Technical specifications

Linear
Linear M13-631 User manual

Linear
Linear MULTI-CODE 4200 User manual

Linear
Linear WEATHER RESISTANT KEYLESS ENTRY SYSTEM AK-2W Technical specifications

Linear
Linear AE2000PLUS User manual