Lintec MC-5000L Series User manual

LN0364E2109D0
Mass Flow Controller for DeviceNet™
Instruction Manual
MC-5000L Series
Safety Precautions
Incorrect handling may cause death or injury
(1) Before connecting the fittings, check that no damage or defects are found on the fittings.
Make connections properly and make sure that a leak test is conducted before actual
operation to prevent fluid from leaking into the atmosphere (Hereinafter, the fluid used
is referred as “gas” or “fluid”).
(2) DO NOT apply any corrosive fluid to materials exposed to gas. Corrosion may cause gas
to leak into the atmosphere.
(3) This device is not designed as an explosion proof structure. DO NOT use this device in a
place where explosion-proof structures are required. Doing so may cause fire or explosion.
Incorrect handling mayleadtomediumorslight injury ormay
causedamageto,orlossof,facilitiesorequipment
(1) Observe the precautions listed in the WARNING (above).
(2) Strictly observe the electrical specifications. Not doing so may cause fire, damage to
sensors or malfunction.
(3) This device is not designed to be waterproof. DO NOT locate this device outdoors or in a
place where it may be splashed with water. Doing so may cause fire, trouble, or
malfunction of the device.
(4) DO NOT modify this device. It may cause fire or other problems.
(5) This device is not designed to handle hot swap. Please avoid attaching and removing the
power supply connector and interface connector with the power switched on. Attachment
and/or removal with the power on may result in failure of the device.
(6) This device is a precious device, please handle it carefully. Dropping down or handling it
carelessly will cause damage. Please use assist instrument while moving or setting the
device.
(7) Regular maintenance is recommended for steady use of this device (Recommended
proofreading frequency is once a year).
1. Introduction
This manual explains basic operation of the MC-5000L series (Hereinafter referred
as "MFC"). MFC is equipped with a network interface, and can be operated by
connecting to a network environment of DeviceNet ™.
Since MFC is a slave device, please prepare a master device of DeviceNet ™
network interface.
The device profile follows the MFC profile in ODVA specification.
Please go through the ODVA specification and device profile manual of MC-5000L
for proper use.
2. Summary
The MFC is high performance mass flow controller for gas using thermal flow
sensor and high response piezoelectric valve. In the MFC model, MO type and
MC type are available depending on the kind of valve operation mode. Also,
MFC interface employs Device Net™ network, so MFC is compatible with other
makers.
3. Features
The MFC is the following features.
(1)
LINTEC’s proprietary ambient temperature compensation type flow sensor is carried.
· Low sensor temperature, long-time steady monitor, and few problems such
as degradation of gas to be monitored.
·The effect of ambient temperature is less because the sensor temperature is
kept at the ambient temperature.
·Steady temperature distribution of sensor and high-speed response.
(2) Digital computing system with microprocessor and high-resolution A/D, D/A
converter is carried.
· High functionality.
·By setting of device number (address), multiple devices can be controlled
through a single interface.
· Many additional are provided as standard, e.g., totalizer function, zero adjust,
ramping function.
(3) MFC employs DeviceNet™ network protocol.
(4) Small dead space structure using a diaphragm valve.
(5) Single power supply 11 to 25VDC.
(6) Superior corrosion resistant sealing materials make maintenance easy. Metal
seals (Au).
(7) Particle-free structure.
(8) By using a metal case and various types of filters, steady operation can achieve
even in an environment of high-frequency noise and stationary magnetic field.
(9) Based on RoHS.
4. Structure
The MFC consists of sensors, bypass, valves, and a microcomputer for signal
processing. A digital PID feedback control system controls the valve action so that
flow rate output from the sensor agrees with flow rate setting value.
5. Specification / Dimensions
(1) Specification
Name
Mass Flow Controller
Model
MC-5100L
MC-5200L
MC-5250L
Flow rate range
(N2 conversion)
10SCCM to 5 SLM
~20SLM
~50SLM
Valve operation mode
Normally open / Normally closed
Surface treatment
Precision polishing
Minimumcontrollableflowrate
2%F.S.
Accuracy
100%F.S. to 10%F.S. ±1.0%S.P.
10%F.S. to 2%F.S. ±0.1%F.S.
Repeatability
±0.2%F.S.
Response time
1 second (Typical)
Operating differential
pressure
50 to 300kPa
Normally open
50 to 300kPa (
~
10SLM)
100 to 300kPa (10 to 20SLM)
Normally closed
100 to 300kPa (
~
10SLM)
200 to 300kPa (10 to 20SLM)
100 to 300kPa
(
~
30SLM)
150 to 300kPa
(
~
50SLM)
Maximum operating
pressure (Note1)
300kPa(G)
Withstanding pressure
1MPa(G)
Operating
temperature
&
Humidity
5 to 50ºC·0 to 80%RH (Condensation should be avoided)
Storage temperature &
Humidity
0 to 60ºC·0 to 80%RH (Condensation should be avoided)
Leak integrity
Less than 1×10-11Pa · m3/sec (He)
Mounting direction
Free
Wetted materials
Stainless steel 316L, PCTFE, PTFE, Au
Seal Materials
Au
Actuator
Piezoelectric actuator
Fittings
6.35VCR (106mm, 124mm)
1.125 W-Seal 79.8mm, 1.125 W-Seal 92mm
Power supply
11 to 25VDC (5VA max.)
Digital interface
DeviceNet™
Optional
B: Liquefied gas, G: Minimum control flow rate 0.5%F.S.
E: Small Range Control 1 to 10SCCM in nitrogen
J: Valve is closed at below 2% setting, M: Applied to ClF3
Weight
Approx. 1kg
Name
Mass Flow Controller
Model
MC-5460L
MC-5470L
Flow rate range
(N2 conversion)
~150 SLM
~200SLM
Valve operation mode
Normally closed
Surface treatment
Precision polishing
Minimumcontrollableflowrate
2%F.S.
Accuracy
100%F.S. to 35%F.S.
±1.0%S.P.
35%F.S. to 2%F.S.
±0.35%F.S.
1.0%F.S.
Repeatability
±0.5%F.S.
Response time
1 second (Typical)
Operating differential
pressure
250 to 500kPa
350 to 500kPa
Maximum operating
pressure (Note1)
500kPa(G)
Withstanding pressure
1MPa(G)
Operating
temperature
&
Humidity
5 to 50ºC·0 to 80%RH (Condensation should be avoided)
Storage temperature &
Humidity
0 to 60ºC·0 to 80%RH (Condensation should be avoided)
Leak integrity
Less than 1×10-11Pa · m3/sec (He)
Mounting direction
Free
Wetted materials
Stainless steel 304, Stainless steel 316L, Teflon, Viton, Au
Seal Materials
Au
Actuator
Piezoelectric actuator
Fittings
6.35UJR156mm, 9.52UJR163.4mm
Power supply
11 to 25VDC (5VA max.)
Digital interface
DeviceNet™
Optional
J: Valve is closed at below 2% setting
Weight
Approx. 1.4kg
Note1)There is a possibility that the gas does not flow in case of the gas pressure of more than
490kPa was used on the MC-5250L- MO /NO.
· ConnecttheMFC to theframeground.

(2) Dimensions
MC-5100L, MC-5200L, MC-5250L
MC-5460L, MC-5470L
6. Ordering information
MC-510*L –MO –4JR1 AA0A0 –dd –ee –ff
[1] [2] [3] [4] [5] [6] [7]
[1] Series model MC: Mass Flow Controller Series
MC-5100L, MC-5200L, MC-5250L, MC-5460L, MC-5470L
*Power connector orientation 0: Side direction, 1: Upper direction
[2] Valve mode
MO: Normally open (Precision polishing)
MC: Normally close (Precision polishing)
[3] Fitting size
4VR1:6.35VCR106, 4VR2:6.35VCR124, 4SWL:6.35SWL
SPW3: Surface mount 1.1.25W-Seal 79.8mm,
SPW4: Surface mount 1.125W-Seal 92mm
6JR3: 9.52UJR163.4mm, 4JR4: 6.35UJR156mm (Applied to MC-5460L and MC-5470L)
※ Please consult for more information.
[4] Optional
B: Applied to liquefied gas,
E: Small Range Control (1 to 4SCCM in nitrogen)
G:
Wide Range specifications (Control range 0.5 to 100 %F.S.)
J:
Valve is closed at below 2% setting, M: Applied to ClF3
※ Default setting is labeled
“AA0A0”.
Please consult for more information.
[5] Gas type
[6] Full scale flow rate
[7] Flow rate unit
SCCM (0 ºC standard), SLM (0 ºC standard)
7. Connection
(1) DeviceNet™ connector: Pin type micro connector (IEC60947-5-2)
Pin No.
Signal name
Function
1
Drain
Shield
2
V+
Power supply 11 to 25VDC (+)
3
V-
Power supply (-)
4
CAN_H
CAN interface HI
5
CAN_L
CAN interface LO
(2) Rotary switch, LED (on top of the MFC housing)
8. Operation
Procedure
1) This product is packed in a clean room before shipment. Please break the
seals in a clean room after taking it out of its box.
2) Check the gas type and flow rate, and check the direction of the gas flow
and the MFC before installation.
3) Check for gas leaks from the tubing with a helium (He) leak detector.
4) Prepare a master for DeviceNet™ and connect specified power, cable and
connector.
5) Connect to the network.
6) Turn on power supply and let the equipment warm up for at least 5 minutes
(Recommended time: 30min).
7) Please power on the MFC for 30 mins, then conduct zero-point adjustment
without gas flowing by pressing button on the top of device or software.
8) Device starts controlling flow after inputting setting value by software and
introducing gas with the specific pressure.
9) Complete shut off cannot be achieved with the mass flow controller. If
complete shut off is desired, a shut-off valve should be installed.
10) When a highly reactive gas is used, thoroughly purge all foreign matter
from the tubing and the MFC before operation.
11) When contaminated gas is used, install a filter at the equipment inlet.
9. Product warranty
(1) Period
This product is guaranteed for a period of 1 year from date of shipment. Defects
are repaired according to the following regulations.
(2) Scope
Warranty coverage is restricted to this product only. Any other damage caused
by this product is not covered.
(3) Disclaimer facts
The following repairs are not covered by the warranty:
1) Failure caused by by-product of fluid used.
2) Failurecausedbymisuse(includingcarelessoperation)orincorrectrepairormodification.
3) Failure caused by dropping after purchasing.
4) Failure caused by a natural disasters.
Even if the warranty period is still in effect, the following items may notbe repaired.
1) When the kind of fluid used in the product is unclear.
2) The product is returned with fluid remaining inside and safety cannot be
confirmed.
The MFC is a precision instrument. Control may become unstable if electric
noise, temperature change of fluid, pulsation of fluid pressure etc. occurs.
Please be forewarned.
This instruction manual is subject to revision without notice.
http://www.lintec-mfc.co.jp
CorporateHeadquarters
4-1-23Sekinotsu,Otsu City, ShigaPref.520-2277,Japan
TEL. +81-(0)77-536-2210FAX.+81-(0)77-536-2215
TokyoBranchOffice
3FHattoriBuild.,4-30-14YotsuyaShinjyuku-kuTokyo160-0004,Japan
TEL. +81-(0)3-5366-2801FAX.+81-(0)3-3341-3513
NET
Network Status
Network Status LED
MOD
Module Status
Module Status LED
ZERO ADJ.
Zero Adjustment
Zero Adjustment button
Display
Name
Description
Default
MSD
LSD
Node
Address
Decimal setting:
MSD: a digit in tens place
LSD: a digit in ones place
The setting number above 64 will be Software Set
Mode.
63
RATE
Data Rate
Baud rate switch
1: 125 kbps
2: 250 kbps
5: 500 kbps
Otherwise: Software set mode
5
This manual suits for next models
5
Other Lintec Controllers manuals
Popular Controllers manuals by other brands

Alpine
Alpine KTX-H100 owner's manual

ACS Tech80
ACS Tech80 SB1391 manual

Mitsubishi
Mitsubishi MELSEC Q Series Programming manual

SSD Drives
SSD Drives 690+ Series product manual

NexWatch
NexWatch PW-3000 installation manual

Lattice Semiconductor
Lattice Semiconductor ispLever Core Multi-Channel DMA Controller user guide