Local Control Network LCN-GT10D User manual

LCN-GT10D
Installation guide Local Control Network
®
1
Glass touch- keypad with 10 keys, 2,8” TFT- colour display, timer switch and
temperature sensor
The LCN-GT10D is a 10-key glass touch-keypad with
display for the I-port of any LCN module with version
140719 (Juli 2010) or after. It is suitable for temperature
regulation, due to it´s intregated temperature sensor.
®
A Corona surrounding light with white LED´s, serves as
a decorative accent lighting and as a discreet
orientation light, so that the LCN-GT4D can be comfor-
tably operated even with a low environmental light.
Apart from that, the bottom 6 keys D1..D6 are supplied
with a blue background light. Each of the 6 keys has an
integrated status LED that can be individually controlled or
react to status messages.
The 4 capacitive working sensor keys are situated behind
a 5 mm thick glass front. A slight touch on the surface
area is enough to trigger off the functions.
The inscriptions on the bottom 6 sensor keys are carried
out individually per inlay - changeable at any time without
difficulty.
X3 X4
X1 X2
Mo 31.12.2019 11:55:59
shutter automatic on
outside temperature 17,4°C
GARAGE
temp. +
temp. -
window OPEN/CLOSE Auto ON/OFF
D1
L1
D2
L2
D3
L3
D4
L4
D5
L5
D6
L6

LCN-GT10D Installation guide
building controls in perfection
2
®
Scope of delivery
LCN-GT10D, LCN-NUI (power supply), mounting frame, 4 screws 3,2 x 15mm, inlay for
inscription, pen, CD &1 sheet of paper (blank).
How it functions
The sensor keys on the LCN-GT10D react to touches on the glass surface. Depending
on the duration of contact, an appropriate LCN-control command (Short, LONG or
RELEASE) will be sent. When no configurations are made to the keys, the keys are
assigned as follows: X1 - X4 work on the keys in the A table according to their numbers.
The bottom 6 sensor keys work on the D table of the module. Further information can be
found in the online help on the LCN-PRO. A signal sound (can be swithed off) informs
over key contact. There is the possibility to trigger off further keys, by touching two keys
at the same time. Keys D1+D6 trigger off D7 and D2+D5 the key D8. This type of
double touching is especially suitable for functions that may not be triggered accidental-
ly (central off, switching the alarm system, etc).
The 6 status-LED´s in the bottom sensor keys can be programmed individually (ON,
OFF, BLINKS, FLICKERS).

3
LCN-GT10D
Installation guide Local Control Network
®
®
The Corona -surrounding light is controlled over the LED-command “GT-brightness”.
®
The brightness of the status-LED´s can be altered in 2 steps and the Corona -surrounding
light is adjustable in several steps. On the 2,8” TFT-colour display, six symbols, 3 text
rows with each 63 characters and 4 fields for the key captions, can be shown. If the key
captions are not needed, then even 4 text rows are possible.The LCN-GT4D supports a
language changing: german, english, french, spanish, polish, turkish, russian and
arabian, that can be toggled during operation. The appropriate command can be found in
the LCN-PRO. The display texts for other languages are entered in the LCN-PRO under “
3 Ports / I-Port”.
The LCN-GT4D has a built in 24-channel timer switch with 96
switching time periods. The 24 channels can be freely
described in the LCN-PRO, so That a simple change of
switching time periods can be carried out through the user.
The user menu is called up through touching the keys X2+X3
at the same time - see also online help in the LCN-PRO.
X4
X1
Timer switch
Public holidays
Bank holidays
Set date/time
X2
X3

4
LCN-GT10D Installation guide
building controls in perfection
®
Installation
The LCN-GT10D must not “tilt” on the wall, as this will lead to false triggering.
That is why the edge of the flush mounted box or
cavity wall box must be countersunk when
installing, to guarantee a stable fixing and a
flawless function of the LCN-GT10D.
The LCN-GT10D must not “tilt” on
the wall, as this will lead to false triggering. That
is why the edge of the flush mounted box or cavity wall box must be countersunk when
installing to guarantee a stable fixing and a flawless function of the LCN-GT10D. When
Installing on Kaiser cavity wall flush mounted boxes, the seperating strip must be removed
from the middle of the box, as this protrudes around 0,5mm.
Pull out the plastic slider a few millimetres on the LCN-GT10D when fixing to the supplied
mounting frame. When the slider is pressed back in, The LCN-GT10D is locked firmly to the
mounting frame.
Note:
Important:
Important:
When the temperature sensor is being used, the LCN-GT4D should not be installed
near heating sources, lights, cooling devices or a loaded (warm) LCN-UPP´s, because
these factors falsify the temperature value. In this case it is better to install an additional
LCN-GRT!
CD

5
LCN-GT10D
Installation guide Local Control Network
®
Connect the mounting frame
to the I-port and screw to the
flush mounted box.
Pull out the plastic slider
sideways at the rear side of
the key-sensor until it resists
(about 8mm), and insert the
LCN-GT10D at a slight angle
from the bottom towards the
m o u n ti n g f ra m e . A t t h e
bottom area, the LCN-GT10D
must be hooked into the
co rner s of t h e mou ntin g
frame and pressed towards
the wall.
T h r o u g h p u s h i n g i n t h e
plastic slider on the side, the
LCN-GT10D is locked firmly
onto the mounting frame. Insert guiding pins at an
angle from the bottom
engage to the bottom
corners in a slanted
movement
press the LCN-GT4D
towards the wall, lock
slides on the side
3.
1. 2.

extension:
max. 20m!
L
N
Power on
LCN-NUI
ISSENDORFF KG
85-264V~
50/60Hz, Pmax 2,5W
Schwarz/black
Blau/blue
LED
±20
26V~ %
50Hz, Pv<0,4W
Schwarz / black
Blau / blue
Weiß / white
230V~
GND
Daten
LCN-UPP
ISSENDORFF KG
D
L
N
PE D
L
N
PE
L
N
Power on
LCN-NUI
ISSENDORFF KG
85-264V~
50/60Hz, Pmax 2,5W
Schwarz/black
Blau/blue
LED
±20
26V~ %
50Hz, Pv<0,4W
Schwarz / black
Blau / blue
Weiß / white
230V~
GND
Daten
LCN-UPP
ISSENDORFF KG
Mo 31.12.2019 11:55:59
shutter automatic on
outside temperature 17,4°C
GARAGE
temp. +temp. -
window OPEN/CLOSE auto ON/OFF
LCN-IV
6
LCN-GT10D Installation guide
building controls in perfection
®
Connecting the modules
Install the enclosed power supply LCN-NUI in
flush mounted box with the LCN-UPx. Simply
loop the LCN-NUI into the connection cable.
The power supply is given directly over the
four-pole I-port extension. Connect the cable to
the LCN-IV to extend the I-connection of the
LCN-GT10D. (in the graphic: variation right).
I-connection guidelines
The I-connecting cable to the LCN module can be
extended up to 50m (including all sections in
between) with an LCN-IV (use ³0,8mmÆ). But:
The distance from the LCN-NUI to a maximum of
2 GT-key-sensors must not exceed 20 metres.
Please see also ”TDI-connection of peripheries”
on www.LCN.de.
LCN-UPP
bus module
LCN-UPP
bus module
LCN-NUI
power supply
LCN-NUI
power supply
Mo 31.12.2019 11:55:59
shutter automatic on
outside temperature 17,4°C
GARAGE
temp. +temp. -
window OPEN/CLOSE auto ON/OFF

7
LCN-GT10D Installation guide
Local Control Network - building controls in perfection
®
N 1 2 3
N 1 2 3
correct:
The data wires are connected here
from different pairs.
LCN-IV/IVH LCN-IV/IVH
Data
Data
5V+
Data
Data
5V+
Mass (N)
Data
Data
5V+
Mass (N)
Note about I-Port-extension on the LCN-IV/IVH
wrong:
The data wires must not be
connected from just one pair!
Reason:
Through capacitive overcoupling,
it may cause problems with the
data transfer.

8
LCN-GT10D Installation guide
building controls in perfection
®
Bringing into operation
requirements: The LCN-GT10D can be operated on LCN bus modules with firmware
140719 (July 2010) or after and be parametrized with the LCN-PRO version 4.x or after.
Settings: The
Up to 4 periphery devices may be operated parallel to the LCN-GT10D on the I-port, e.g.
LCN-GRT, -RR, -GT3L, -GT2, -GBL, however not the LCN-ULT, -GT4D or IOS-devices.
please see also ”TDI-connection of peripheries”.
When operating the LCN-GT4D/-GT10D, no DALI/DSI signals can be given
out! Operating the LCN-IV as pulse counter / counter input, is not possible! The power
supply for the LCN-GT10D must only be supplied from the LCN-NUI or the optionally
obtainable LCN-NIH .
The status messages from the LCN-GT10D reacts to older LCN modules as follows:
Serial number from sending module retrievable information
060101 (Jan. 1996) . . . . . . . relays- / binary sensors- / sums- / output status
0A0A0B (Oct. 2000) . . . . . . . . . same as 060101, additionally: actual value
100A06 (Oct. 2006) . . . . . . . . . . same as 0A0A0B, additionally: set value
LCN-GT10D is recognized automatically from the module and the tempera-
ture is registered in the variable 4 (R1var) - you can check the value in the analogue status
window of the LCN-PRO.
Important:

9
LCN-GT10D
Installation guide Local Control Network
®
Inscription
You will find the inscription software LCN-GT on the
enclosed CD for designing your inlays. The caption inlay
must be cut to 61 mm * 90 mm. Standard 80g reprogra-
phic paper is suitable and unproblematic for processing.
Semitransparent paper/inlayer is even better for the
optimum luminance of the LED´s.
Inserting the inlay into the key-sensor
Pull the plastic slider at the rear of the key-sensor to the
side. Guide the inlay through the slit on the bottom edge
of the LCN-GT10D as far as it will go.
Tip: When each corner of the inlay is trimmed around
2mm, it is easier to guide through the slit. When changing
the inlay/paper, the GT10D should be removed from the
wall.

LCN-GT10D Installationsanleitung
Gebäudeleittechnik in Perfektion
10
®

11
LCN-GT10D
Installation guide Local Control Network
®
information:
Technical data LCN-NUI
input voltage: LCN-NUI
2
connection input voltage: 2 wires with wire end-sleeves 0,75mm
output voltage: 5V DC (stable)
power output: max. 2,5W
connection output voltage: 3 I-port connectors
environmental temperature: -10°C to + 40°C
air humidity: max. 80% rel., non condensing
usage: stationary installation according to VDE632, VDE637
protection art: IP20
dimensions: ø 50mm x 22mm
® 110V - 230V AC 15%, 50/60Hz±
Important note:
Despite its extensive functionalities, the LCN system is simple to install and programme: It´s
all in the hands of the electrician. However a training course is necessary for every
electrician who installs this system. The direct users support over the telephone hotline,
is only free of charge and open to installers who have taken part in a training course.

12 changes are reserved. ISSENDORFF KG, 31157 Sarstedt
LCN-GT10D D08/2013
LCN-GT10D Installation guide
building controls in perfection
®
Technical data
Connections
power supply: over the I-port (with LCN-NUI/-NIH)
LCN-connection: sliding contacts to connect on to the mounting frame
Function
keys: 10 capacitive sensor areas behind glass, with the
functions: SHORT / LONG / RELEASE
LED´s: 6 LED´s to show LCN status messages
functions:: OFF / BLINKING / FLICKERING / ON
®
White Corona -LED´s controllable over command
“GT-brightness”, functions: OFF / BLINKING / FLICKERING / ON
the brightness is adjustable in steps
key background-LED´s (blue), functions: ON / OFF
display: 2,8” (71mm) TFT-colour display (320x240 pixels), 65536 colours
timer switch: 24 channels with 96 switching times
temperature sensor: measuring range from
dimensions (W x H x D): 90mm x 160mm x 15,5mm (5mm glass thickness)
environment: -10°C to +40°C, air humidity: max. 80% rel., non condensing
usage: stationary installation according to VDE632, VDE637
protection art: IP 20
installation: install on two flush mounted boxes
-10°C to +40°, triggering 0,1°C
accuracy type 0,3°C from +15°C to +30°C
Installation
Popular Keypad manuals by other brands

CDVI
CDVI C2R quick start guide

Identiv
Identiv 8210 uTrust TS user manual

AES global
AES global KPX1200 quick start guide

SOMFY
SOMFY 2 RTS Quick installation

DMP Electronics
DMP Electronics Thinline 7463 Installation and programming guide

Balcrank
Balcrank FUSION 3110-013 Operation, installation, maintenance and repair guide