CDVI Digicode PROFIL100EC User manual

The installer’s choice
cdvi.se
PROFIL100EC
SVENSKA
SE
ENGLISH
EN
Vattentätt kodlås med bakgrundsbelysning i delat montage
Illuminated Mullion Weatherproof Keypad Remote Electronics

2
HIGH RESISTANCE
TO VANDALISM
IP52
CE certication
PROFIL100EC
Illuminated Mullion Weatherproof Keypad EN
INSTALLATION MANUAL
Remote electronics, supplied
with the PROFIL100EC keypad
IP67
-25°C to +70°C
-25°C to +70°C
CE certication
Environmental tests:
vibrations
WEEE & RoHS
Mounting plate
for remote
electronics box
Wiring
sealed cap Varistor
(M5x8
Diax®
screw)
T20 Diax®
Spanner
Plastic
anchors
(M4x30)
mounting
screws
Remote electronics 1 2 - - - 2 2
PROFIL100EC
- -11122
1] PRODUCT PRESENTATION
Stainless steel.
Narrow: Ideal for installation
on an aluminium section.
Backlit.
2 relays.
Recommended for activating
and deactivating your alarm system.
Surface-mount.
Free voltage.
Installation with Diax®screws.
PCB of remote electronics
protected with a varnish coating.
100 user codes.
Audible and visual feedback.
Dimensions (L x W x D): 165 x 43 x 27mm.
Power supplies:
12V to 24V ac or 12V to 48V dc.
Consumptions: 30 to 100mA.
3] MOUNTING KIT
2] NOTES & RECOMMENDATIONS
Cable
- The distance between the PROFIL100EC
and the remote electronic can not exceed
more than 50 meters.
- Make sure that the cable is not near by a high
voltage cables (ex: 230V ac).
-Recommended cable between the PROFIL100EC
and the remote electronics: 2 twisted pairs
(4 wires) SYT1 0.8MM.
Mounting recommendations
Mount the keypad on a at surface to avoid
any vandalism and to insure the best mounting.
Security advice
- For security advice reasons, change
the factory default master code.
- When selecting a master code and user code
avoid simple codes (example : 3 4 5 6 7).
Installation recommendations
To secure the system from back electromagnetic
elds do not forget to mount the varistor
in parallel on the lock.
Recommended power supplies
suitable for the PROFIL100EC
ARD12 (230V input) or BS60 (230V input).
2cdvi.se
cdvigroup.com

3
1 2 3
456
PROFIL100EC
Illuminated Mullion Weatherproof Keypad EN
INSTALLATION MANUAL
4] MOUNTING INSTRUCTIONS
Once you have made sure that the mounting kit is complete and that you prepared the cables
of the PROFIL100EC keypad and its remote electronic then you can proceed and mount the
product. Make sure that you have all the appropriate tools (drill, screw drivers and a
meter
tape...) and follow the mounting instructions for the PROFIL100EC and its remote electronic.
Verify the distance
between the PROFIL100EC
keypad and its remote
electronic (refer to page 3,
Notes and Recommendations).
Place the back plate of the
PROFIL100EC on the wall and
the bracket of the remote
electronic then mark with a pen
the hole location then drill the
2 mounting holes (5mm drill
bit Ø and 35mm hole depth)
and the hole wiring access.
Fasten the PROFIL100EC
keypad to the back plate by
using the supplied (M5x8) Diax®
screw and T20 Diax®spanner
hardware.
Insert the 2 plastic anchors
in the holes. Mount the back
plate of the PROFIL100EC with
the (M4x30) mounting screws.
Insert the 2 plastic anchors
in the holes. Place the bracket
of the electronic and screw
on the wall using the supplied
M4x30 screws. Slide the box
from up to down on the bracket.
Insert the cable in the hole
access area of the back plate.
Then mount the keypad on
the back plate, placing rst
the top in the hooks and then
the bottom.
Insert the cable in the remote
electronic and wire the cable
to the terminals. Don’t forget
to install the varistor on the
lock (refer to page 3, Notes
and Recommendations‘).
3
cdvi.se
cdvigroup.com

PROFIL100EC
Illuminated Mullion Weatherproof Keypad EN
INSTALLATION MANUAL
4cdvi.se
cdvigroup.com
5] WIRING DIAGRAM
D - 693: Remote electronics
P3 jumper allows to the
user to modify its own
Pin code. To enable this
feature put the jumper on.
(see Programming section
in the instruction manual)
P2 jumper resets the keypad
to factory default values. Remove
the power from the keypad then put
the jumper. (see Programming section
in the instruction manual)
Fail safe lock
Fail secure lock
Varistor
Input voltage
12 to 24V ac
or 12 to 48V dc
Power supply
According to lock
specications
Relay
1
Relay
2
Outputs Description
V
Input voltage 12V to 24V ac or 12V to 48V dc
V
Input voltage 12V to 24V ac or 12V to 48V dc
R1 N/C contact relay 1
C1 Common relay 1
T1 N/O contact relay 1
R2 N/C contact relay 2
C2 Common relay 2
T2 N/O contact relay 2
P1 Request-to-exit input relay 1
MCommon of inputs
P2 Request-to-exit input relay 2
PX Request-to-enter input
HTimer Contact
+White wire from keypad
-Brown wire from keypad
EGreen or Blue wire (illumination)
Request-to-Exit inputs
- P1 request-to-exit input
activates relay 1.
- P2 request-to-exit input
activates relay 2.
- Latch or toggled output.
H input can be used with
a timer to enable the
request-to-enter function.
(Press the button on the
keypad with the key logo
When the contact is open then
the request-to-enter is disabled.
When the contact is closed then
press the button with the key
logo to enter.

PROFIL100EC
Illuminated Mullion Weatherproof Keypad EN
INSTALLATION MANUAL
5
cdvi.se
cdvigroup.com
A. Reset master code
and user codes
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to conrm entry
in programming mode.
2. Press A6 to reset the Master Code
and the User codes.
- One beep is emitted.
- Press on Aand B to conrm reset
of all memory of the keypad.
- Wait for two beeps.
- The master code is restored to its default
value 1 2 3 4 5 and all the User codes
are deleted from the keypad.
- Once the reset is completed then the keypad
returns to a stand-by operating mode.
OR
1. Cut the power. Place the jumper on P2.
2. Put the power back.
-Wait approximately 3 seconds.
- Two beeps are emitted to conrm reset
of the keypad.
- Remove P2 jumper.
- The master code is restored to its default
value 1 2 3 4 5 and all the User codes
are deleted from the keypad.
B. Setting code length
1. Enter the master code twice.
(1 2 3 4 5 default value master code).
2 beeps are emitted to conrm entry
in programming mode.
2. Press A4 to program the code length.
- One beep is emitted.
- Press 4or 5for the digit code.
- One beep is emitted to conrm
programming of the code length.
3. Press A5 to modify the master code.
- One beep is emitted.
- Enter the new 4 or 5-digits master code.
- One beep is emitted to conrm
programming of the new master code.
4. Press B to exit from
programming mode.
2 beeps are emitted to conrm that the
keypad is in stand-by operating mode.
4 beeps indicate a data computing error.
Default values
- Without codes.
- Illumination time: 10 seconds.
- Relay release time: 1 second.
- Code length: 5-digits.
- Master Code: 1 2 3 4 5.
- Programming security time :
120 secondes.
- Code length for sub master code:
Version 1 relay
(Group 1) = AB,
Version 2 relays
(Group 2) = 13.
Audible signal:
- The buzzer indicates different
audible signals.
- It can be turned off by cutting
the ST1 wire on the remote
electronics.
- 1 short beep: Keypad powered.
- 1 long beep: Data computing
in programming or access
granted.
- 2 short beeps: Enter or Exit
from programming.
- 4 short beeps:
data computing error.
Code length
- The master code and the User
codes can be of 4 or 5-digits
in length.
- All the keypad keys can be used
to program a code.
- The master code and the Pin code
can be of 4 or 5-digits code.
- The master code CAN NOT
be used as a PIN code
(User Pin code).
- To delete a specic User pin Code
replace it by 0 0 0 0 if code
length is 4-digits format or
replace it by 0 0 0 0 0 if the
code is in 5-digits format.
P2 jumper:
Reset master code and user
codes
P3 jumper:
Modication of individual
code by the user

PROFIL100EC
Illuminated Mullion Weatherproof Keypad EN
INSTALLATION MANUAL
6cdvi.se
cdvigroup.com
C. Changing the master code
The master code is used only
to enter in programming mode.
1. Enter the master code twice.
(1 2 3 4 5 default value master code).
2 beeps are emitted to conrm
entry in programming mode.
2. Press A5 to modify the master code.
- One beep is emitted.
- Enter the new 4 or 5 digits master code.
- One beep is emitted to conrm
that the master code is programmed.
3. Press B to exit
from the programming mode.
2 beeps are emitted to conrm that
the keypad is in stand-by operating mode.
D. Adding, changing
or deleting a user code
Group 1: From address 00 to address 99,
relay output 1
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to conrm entry
in programming mode.
2. To add a user code, enter the user
location (from 00 to 99).
If the user location is used 4 beeps
are emitted, enter the 4 or 5-digits
User code.
3. To Change a User code enter
the user location.
-4 beeps are emitted to indicate that
the user location is already programmed.
- Enter a new 4 or 5-digits code.
- A beep is emitted to conrm the new
user code.
4. To delete a User code enter
the user location.
-4 beeps are emitted.
- Press 0 0 0 0 0 in 5-digits length code
or 0 0 0 0 in 4-digits length code.
- A beep is emitted to conrm the user
code has been deleted.
Note:
If the Pin code is already programmed or is
identical to the master code, then 4 beeps are
emitted. Press B to exit from the programming
mode. 2 beeps are emitted to conrm that the
keypad is in stand-by operating mode.
E. Time outputs
This section allows to program
the illumination time and the Relay
activation time.
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to conrm
entry in programming mode.
2. Press A0 to program the key-in
keypad time and the keys lit time.
1 beep is emitted.
-Enter the time in 10th of second – 10 for
10 seconds up to 99 for 99 seconds
The backlighting dims 10 seconds after
the last keypress or switches off after
entering a valid code.
- Press 00 for permanent illumination keys.
- One beep is emitted to validate the time.
3. Press A1 to program relay 1
output time (door release time).
-1 beep is emitted.
- For a latched output enter the time
in seconds – 01 for 1 second up to 99
for 99 seconds.
- Press 00 for a toggled output.
- One beep is emitted to validate the time.
4. Press B to exit from
programming mode.
2 beeps are emitted to conrm that
the keypad is in stand-by operating mode.
4 beeps indicate a data computing error.

PROFIL100EC
Illuminated Mullion Weatherproof Keypad EN
INSTALLATION MANUAL
7
cdvi.se
cdvigroup.com
F. Reset master code
On stand-by operating mode,
put a jumper on P2.
-Wait 1 second and then remove the jumper.
- One beep is emitted.
- The master code is restored to its default
value 1 2 3 4 5 in 5-digits code and 1 2 3 4
in 4-digits code.
G. Changing the code by a user
To authorize a user to modify its own
User code place the jumper on P3
(
to disable the function remove the jumper).
1. Enter the old user code.
The relay is activated and a beep is emitted.
2. Enter the 2-digits sub master code
(default sub master code AB).
A beep is emitted to authorise the modication.
3. Enter the new user code.
2 beeps are emitted to conrm
the new code.
4. Check the new user code to be sure
ofthemodication.
H. Setting a sub master code
The Sub Master code allows the user
to change its own code without entering
in programming mode. For security
reasons the code need to be changed
periodically. This feature makes it easier
and faster to change its code.
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to conrm entry
in programming mode.
2. Press A7 to program a sub master
code for the user individual Pin
codemodication.
-One beep is emitted.
- Enter the new 2-digits sub master code.
- One beep is emitted to conrm
programming of the sub master code.
3. Press B to exit
from the programming mode.
2 beeps are emitted to conrm that the
keypad is in stand-by operating mode.
I. Audible Feedback
The audible signal is enabled in programming
mode and when the relay is energised
after a valid code. To enable the audible
feedback on a key press:
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to conrm entry
in programming mode.
2. Press AA.
-One beep is emitted.
- Press 0to disable the audible signal
during a keypress.
- Press 1to enable the audible signal
during a keypress.
- One beep conrms the new setting.
3. Press B to exit from programming.
2 beeps are emitted to conrm exit
from programming mode.
J. Use of the red and green LEDs:
-The red and green LEDs are designed
to receive 12V dc (built-in resistors),
- They are wired as follows:
Orange
12V dc
Gray
0V
Pink
12V dc
Blue
0V
2.2KΩ
2.2KΩ
Red LED
Green LED

Enter Master code
twice
Illumination
duration
10-99 sec
00=Permanent
01=Default
Time relay 1
01 - 99 sec.
00 = Toggled
01=Default
Time relay 2
01 - 99 sec.
00 = Toggled
01=Default
Code length
4’ or 5’ digits
5 = Default
Master code
Change
master code
12345 = Défaut
PROFIL100EC
Illuminated Mullion Weatherproof Keypad EN
INSTALLATION MANUAL
2 x beeps
1 x beep
1 x beep = OK
4 beeps = ERROR
A0
1 x beep
1 x beep = OK
4 beeps = ERROR
A1
1 x beep
1 x pip = OK
4 pip = ERROR
A2
1 x beep
1 x beep = OK
4 beeps = ERROR
A4
1 x beep
1 x beep = OK
4 beeps = ERROR
A5
8cdvi.se
cdvigroup.com
6] Chart

2 beeps
0 = Buzzer
disabled
1 = Buzzer
enabled
Buzzer (audible
feedback)
Press A then B
Reset
2 digits
AB = Default
Sub master
code 1
2 digits
13 = Default
Sub master
code 2 User codes
4 or 5 digit code
4 beeps =
User location: “used”
1 beep =
User location: “free”
PROFIL100EC
Illuminated Mullion Weatherproof Keypad EN
INSTALLATION MANUAL
1 x beep
AA
2 x beeps = OK
A6
1 x beep
1 x beep = OK
4 beeps = ERROR
A7
1 x beep
1 x beep = OK
4 beeps = ERROR
A8
1 x beep = OK
00-99
Press B to exit from
programming
1 x beep = OK
4 beeps = ERROR
1 x beep
9
cdvi.se
cdvigroup.com
6] Chart

PROFIL100EC
Illuminated Mullion Weatherproof Keypad EN
INSTALLATION MANUAL
10 cdvi.se
cdvigroup.com
This spread sheet will help you keep track of the user codes programmed in the keypad
User
location Code Name
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Relay 1 (1 output)
From user location 00 to 59. Relay 2 (2 output)
From user location 60 to 99.
NOTE
User
location Code Name
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
User
location Code Name
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99

PROFIL100EC
Illuminated Mullion Weatherproof Keypad EN
INSTALLATION MANUAL
11
cdvi.se
cdvigroup.com
7] LIMITED LIFETIME WARRANTY [EXTRACT]*
CDVI warrants this product to be free from defects in material and workmanship, when it has been installed in
accordance with the manufacturer’s instructions and has not been modied or tampered with. Only product
recognized by CDVI to be defective should be returned under these warranty terms if accompanied
by an RMA (Return Material Authorization Number) provided by CDVI. CDVI, at its option, shall repair
or replace the defective product at CDVI premises or at any CDVI approved service center. This warranty
does not cover any damage due to accident, misuse, abuse or negligence. This warranty is valid only
if the product is registered, within 1 month from delivery to the nal costumer. To obtain full details of this
warranty and to register the product to commence the “Limited Lifetime Warranty”, complete the enclosed
registration card and return it, either by e-mail or post, to the relevant CDVI address or completion of the
on line registration at www.cdvigroup.com. Repair or replacement of the defective product is the exclusive
remedy. CDVI shall not be liable for any incidental or consequential damages arising from any defect in, or
malfunction of, its product. In no event the entire liability can not exceed the purchase price of the product.
The CDVI local country contact details can be found on line by visiting www.cdvigroup.com or on the back
cover of the installation manual.
DISCLAIMER OF WARRANTY: EXCEPT AS STATED ABOVE, CDVI MAKES NO WARRANTIES, EITHER
EXPRESS OR IMPLIED, AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITION OF ITS PRODUCTS,
THE TRANSPORTATION, THEIR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
*Refer to Limited Lifetime Warranty conditions
8] NOTES

12 cdvi.se
cdvigroup.com
PROFIL100EC
Vattentätt kodlås med bakgrundsbelysning SV
INSTALLATION MANUAL
1] PRODUKTSPECIFIKATION
Rostfritt stål.
Smal : Perfekt för montering
på en aluminiumprol.
Bakgrundsbelysning.
2 relän.
Rekommenderas för att aktivera
och avaktivera larmsystem
.
Utanpåliggande montering.
Fri driftspänning.
Monteras med Diax®skruvar.
Vattentät, IP67.
100 valfria användarkoder.
Indikering med ljud och ljus.
Dimensioner (L x B x H) :
165 x 43 x 27 mm.
Strömförsörjning :
12 V till 24 V AC eller 12 V till 48 V DC.
Strömförbrukning : 30 till 100 mA.
Styrenhet till kodlås PROFIL100EC
HIGH RESISTANCE
TO VANDALISM
IP67
IP52
-25°C till +70°C
-25°C till +70°C
CE godkänd
CE godkänd
Miljötålighetsprov:
vibrationer
WEEE & RoHS
3] MONTERINGSSATS
Monteringsplatta
för styrenhet
Pack-
ningar
Varistor
Diax® för-
sänkt skruv
(M5x8)
Fastnyckel
för Diax®
skruvar
Plast-
plugg
Monterings-
skruv
(M4x30)
Styrenhet 1 2 - - - 2 2
PROFIL100EC
- - 1 1 1 2 2
2] INFORMATION OCH REKOMMENDATIONER
Kablage för PROFIL100EC
- Avståndet mellan kodlåset och styrenheten bör
inte överstiga 50 meter.
- Se till att kablarna inte dras nära
högspänningsledningar (ex: 230 V AC).
- Rekommenderad kabel mellan kodlås och
styrenhet : En fyrledare (4 trådar) SYT1 0,8 mm.
Rekommenderad installation
För att säkra systemet från strömspikar glöm
inte att montera varistorn parallellt med låset.
Förse elslutblecket (elektromagneten) med
varistor om det saknas. Om kodlåset styr
mer än ett elslutbleck ska varje lås förses
med en varistor. Varistorn kontrollerar den
överspänning som produceras av magnetspolen
- backspänningsspikar. Det rekommenderas att
använda en separat spänningskälla när man styr
ett elektromagnetiskt lås.
Säkerhets tips
Av säkerhetsskäl bör den förinställda
standardiserade masterkoden ändras. Vid val av
masterkod och användarkod, undvik sekventiella
koder (ex: 3 4 5 6 7).
Rekommenderad strömförsörjning
Nätaggregat för PROFIL100EC: ARD12 el. ARD24.
Montering av PROFIL100EC
Fäst kodlåset på en plan yta för att förhindra
vandalisering och för att erhålla bästa möjliga
montering.

1 2 3
456
13
cdvi.se
cdvigroup.com
PROFIL100EC
Vattentätt kodlås med bakgrundsbelysning SV
INSTALLATION MANUAL
4] MONTERING
Kontrollera att monteringssatsen är komplett, och att du förberett kablarna till
Digicode®
PROFIL100EC
kodlås och styrenhet innan monteringen påbörjas
.
Försäkra dig om att du har rätt
verktyg tillgängliga (borr, skruvmejsel, måttstock mm) och följ sedan monteringsanvisningarna
för
PROFIL100EC
kodlås och styrenhet.
Kontrollera avståndet mellan
PROFIL100EC
kodlås och
styrenhet
(Se sid 11
«
Information
och rekommendationer
»).
Sätt kodlåsets bakstycke och
styrenhetens monteringsplatta
mot väggen och markera hålens
placering med en penna. Borra
sedan två monteringshål och hål
för kabeln (
Ø 5 mm borr och
minst
35 mm djupt)
.
Stäng knappsatsen till
PROFIL100EC med M4x10 Diax®
skruv och T20 nyckel. Sätt dit
skruvens täcklock.
Sätt två plastpluggar i de
borrade hålen. Placera kodlåsets
bakstycke mot väggen och
skruva fast med de bifogade
monteringsskruvarna (M4x30).
Sätt två plastpluggar i de bor-
rade hålen. Skruva fast styren-
hetens monteringsplatta med
M4x30 skruvar. För styrenheten
uppifrån och ner för att haka
fast den på monteringsplattan.
Trä PROFIL100EC-kabeln
genom kabelhålet i bakstycket.
Kroka fast kodlåset på
bakstycket genom att föra det
uppifrån och ner.
För in kabeln i styrenheten och
anslut med kopplingsplintarna.
Glöm inte installera varistorn
(Se sid 11 «Information och
rekommendationer»).

14 cdvi.se
cdvigroup.com
PROFIL100EC
Vattentätt kodlås med bakgrundsbelysning SV
INSTALLATION MANUAL
5] KOPPLINGSSCHEMA
D693 Styrenhet
P3 : Låter användaren själv
ändra sin PIN-kod.
Byglas för att aktivera den
här funktionen.
(Se «Programmering»)
P2 : Kodlåsets alla inställningar
återställs till fabriksinställning-
arna.
Slå av strömmen och bygla sedan
för att aktivera funktionen (Se
avsnittet «Programmering»)
Strömförsörjning
enligt
låsspecikationen
Omvänd funktion / Magnet
Rättvänd funktion /Elslutbleck
Varistor
Ingång för externa
öppnaknappar
- Ingång P1 aktiverar relä 1.
- Ingång P2
aktiverar
relä 2.
Metod och tidsintervall är
programmerbara.
Timeringång H kan användas
för att aktivera öppnaknappen
med nyckelsymbol.
När kretsen är öppen så är ”nyckel”-
knappen avstängd
, och omvänt, när
kretsen är sluten, så fungerar ”nyckel”-
knappen som en öppnaknapp.
Plint Beskrivning
VInspänning 12-24 V AC eller 12-48 V DC
VInspänning 12-24 V AC eller 12-48 V DC
R1 N/C kontakt (Omvänd funktion), relä 1
C1 Gemensam, relä 1
T1 N/O kontakt (Rättvänd funktion), relä 1
R2 N/C kontakt (Omvänd funktion), relä 2
C2 Gemensam, relä 2
T2 N/O kontakt (Rättvänd funktion), relä 2
P1 Ingång för extern öppnaknapp, relä 1
MGemensam, ingång
P2 Ingång för extern öppnaknapp, relä 2
PX Inbyggd öppnaknapp med nyckelsymbol (gul kabel)
HTimerkontakt
+Vit kabel från knappsats
-Brun kabel från knappsats
EGrön el. blå kabel från knappsats (bakgrundsbelysning)
Relä
1
Relä
2
Vit
Brun
Grön eller blå

15
cdvi.se
cdvigroup.com
PROFIL100EC
Vattentätt kodlås med bakgrundsbelysning SV
INSTALLATION MANUAL
A. Total återställning
(masterkod och användarkoder)
1. Knappa in masterkoden två gånger.
(Masterkodens default-värde : 1 2 3 4 5).
Två pipsignaler bekräftar att man är i pro-
grammeringsläget.
2. Knappa in A6 för att återställa
masterkoden och användarkoderna.
En pipsignal hörs.
3. Tryck på A och B
Detta bekräftar återställningen av kodlåsets
hela minne.
Vänta på två pipsignaler.
Masterkoden återställs till sitt default-värde
( 1 2 3 4 5 ) och alla användarkoder
raderas från knappsatsen. När
återställningen är klar, återgår knappsatsen
till standby-läge.
Eller
1. Slå av strömmen och bygla P2.
För mer ingående instruktioner se avsnittet
om bygling på sidan 16.
2. Slå på strömmen igen.
Vänta ca 3 sekunder. Två pipsignaler
bekräftar att knappsatsen är återställd.
Ta bort byglingen från P2. Masterkoden
återställs till sitt default-värde (1 2 3 4 5)
och alla användarkoder raderas från kodlåset.
B. Ställa in kodlängden
1. Knappa in masterkoden två gånger.
(Masterkodens default-värde är 1 2 3 4 5).
Två pipsignaler bekräftar att man är i
programmeringsläget.
2. Knappa in A4 för att programmera
kodlängden.
En pipsignal hörs. Tryck 4 eller 5
för att ange önskad kodlängd.
En pipsignal bekräftar att kodlängden är
programmerad.
3. Knappa sedan direkt in A5 för att
ändra masterkoden.
En pipsignal hörs. Knappa in en ny 4- eller
5-siffrig masterkod (fyra tecken om ni valt
4-siffrig kod och fem tecken om ni valt
5-siffrig kod under A4 ovan). En pipsignal
bekräftar att den nya masterkoden är pro-
grammerad.
4. Tryck B för att lämna
programmeringsläget.
Två pipsignaler bekräftar att knappsatsen är
i standby-läge och redo att användas.
4 pip indikerar ett databehandlingsfel.
Standard inställningar för
PROFIL100EC :
- Utan koder.
- Tidsinställd belysning :
10 sekunder.
- Reläslutningstid : 1 sekund.
- Kodlängd : 5.
- Masterkod : 1 2 3 4 5.
-
Tidsinställning för
programmering :
120 sekunder.
- Undermasterkod:
Version med 1 relä
(Relä 1) = AB,
Version med 2 relän
(Relä 2) = 13.
Ljudsignal :
-
1 kort pip signal = Kodlåset är
spänningsatt.
- 1 lång pipsignal = Data
sparat i programmeringsläge
eller dörr öppnas.
- 2 korta pipsignaler =
Åtkomst till eller lämna
programmeringsläget.
-
4 korta pipsignaler =
Databehandlingsfel.
Kodlängd :
-
Masterkoden och användar-
koderna kan vara 4- eller
5-siffriga.
-
Alla knappar på knappsatsen
kan användas för att
programmera en kod, även
knapparna A och B.
-
Ändras kodlängden till 4-siffrig
blir även masterkoden
4-siffrig.
-
Masterkoden KAN INTE
användas som användarkod.
-
Koderna
0 0 0 0 0
och
0 0 0 0
kan endast användas för att ta
bort en användarkod.
-
För att ta bort en specik
användarkod: ersätt en 5-siffrig
kod med 00000 och en 4-siffrig
med 0000.
P2 bygling : Total återställning.
P3 bygling : Användaren kan
ändra sin kod själv.

16 cdvi.se
cdvigroup.com
PROFIL100EC
Vattentätt kodlås med bakgrundsbelysning SV
INSTALLATION MANUAL
C. Ändra masterkoden
1. Knappa in masterkoden två gånger.
Vid första användningen används
masterkodens default-värde : 1 2 3 4 5.
Två pipsignaler bekräftar att man är i
programmeringsläget.
2. Knappa in A5.
En pipsignal hörs. Knappa in den nya 4-
eller 5-siffriga masterkoden. En pipsignal
bekräftar att koden är utbytt.
3. Tryck B för att lämna
programmeringsläget.
Två pipsignaler bekräftar att knappsatsen är
i standby-läge redo att användas.
D. Lägga till, ändra eller ta bort en
användarkod
PROFIL100EC
Grupp 1: från plats 00 till 59, reläutgång 1
Grupp 2: från plats 60 till 99, reläutgång 2
1. Knappa in masterkoden två gånger.
Vid första användningen används
masterkodens default-värde : 1 2 3 4 5.
Två pipsignaler bekräftar att man är i
programmeringsläget.
2. Lägga till en användarkod:
Knappa in användarplats,
(mellan 00 och 99). Om användarplatsen är
ledig, hörs en pipsignal. Knappa in den 4-
eller 5-siffriga användarkoden.
3. Ändra en användarkod:
Knappa in användarplats.
Fyra pipsignaler anger att användarplatsen
redan är programmerad. Knappa in en ny 4-
eller 5-siffrig kod. En pipsignal bekräftar den
nya användarkoden.
4. Ta bort en användarkod:
Knappa in användarplats.
4 pipsignaler hörs. Knappa in 0 0 0 0 0
för en 5-siffrig kod eller 0 0 0 0 för en
4-siffrig kod. En pipsignal bekräftar att
användarkoden är raderad.
5. Tryck B för att lämna
programmeringsläget.
Två pipsignaler bekräftar att knappsatsen är
i standby-läge redo att användas.
OBS! Om användarkoden redan är
programmerad eller är densamma som
masterkoden, hörs fyra pipsignaler.
Koderna 00000 och 0000 är reserverade
för borttagning av koder och kan därför
inte användas som användarkoder.
E.
Programmera tider
Avsnittet beskriver programmering av tider för
bakgrundsbelysning och reläaktivering.
1. Knappa in masterkoden två gånger.
Vid första användningen används
masterkodens default-värde : 1 2 3 4 5.
Två pipsignaler bekräftar att man är i
programmeringsläget.
2. Knappa in A0 för att programmera
knappsatsens belysningstid och
dörröppningstid.
En pipsignal hörs. Knappa alltid in tiden
med två
siffror som motsvarar öppettiden i
sekunder -
10 för 10 sekunder upp till 99
för 99 sekunder. Bakgrundsbelysningen lyser
10 sekunder efter sista knapptryckningen
eller släcks efter det en giltig kod matats
in. Knappa in 00 för konstant belysning av
knapparna. En pipsignal bekräftar att tiden
programmerats.
3. Knappa in A1 för att ställa in tiden för
reläutgång 1 (dörröppningstid).
En pipsignal hörs. Om det är en låst utgång,
matas tiden in i sekunder- 01 för 1 sekund
upp till 99 för 99 sekunder. Knappa in
00 om det är en bistabil utgång (reläet
ändrar tillstånd varje gång en korrekt
användarkod anges). En pipsignal bekräftar
programmerad tid.
4. Tryck B för att lämna
programmeringsläget.
Två pipsignaler bekräftar att knappsatsen är
i standby-läge och redo att användas.
4 pip indikerar ett databehandlingsfel.

17
cdvi.se
cdvigroup.com
PROFIL100EC
Vattentätt kodlås med bakgrundsbelysning SV
INSTALLATION MANUAL
F. Återställa masterkoden
I standby-läge, bygla P2. Vänta en sekund
och ta sedan bort byglingen. En pipsignal hörs.
Masterkoden återställs till sitt default-värde,
1 2 3 4 5 för en 5-siffrig kod eller 1 2 3 4 för
en 4-siffrig kod.
G. Användarändring av egen kod
För att en användare ska få tillstånd att ändra
sin egen användarkod ska P3 byglas (för att
avaktivera funktionen, ta bort byglingen).
1. Knappa in den gamla användarkoden.
Reläet aktiveras och en pipsignal hörs.
2. Knappa in den 2-siffriga undermaster-
koden (default-värde är A och B).
En pipsignal bekräftar tillstånd för
ändringen.
3. Knappa in den nya användarkoden.
Två pip signaler bekräftar den nya
användarkoden.
4. Testa den nya användarkoden för att
försäkra dig om att ändringen gjorts.
H. Programmera en
undermasterkod
Med undermasterkoden kan användaren
ändra sin egen kod utan att behöva gå in i
programmeringsläget. Av säkerhetsskäl måste
användarkoderna ändras med jämna mellan-
rum. Med den här funktionen kan användarna
enklare och snabbare ändra sin egen kod.
1. Knappa in masterkoden två gånger.
Vid första användningen används
masterkodens default-värde : 1 2 3 4 5.
Två pipsignaler bekräftar att man är i
programmeringsläget.
2. Knappa in A7 för att programmera en
undermasterkod som ger användaren
möjlighet att ändra sin egen
användarkod.
En pipsignal hörs. Knappa in en ny 2-siffrig
undermasterkod. En pipsignal bekräftar att
undermasterkoden är programmerad.
3. Tryck B för att lämna
programmeringsläget.
Två pipsignaler bekräftar att knappsatsen är
i standby-läge och är redo att användas.
I. Ljudsignal vid knapptryckning
Summern är aktiverad i programmeringsläget
och när reläet är slutet efter inmatning av
giltig kod. För att aktivera ljudindikering vid
knapptryckning:
1. Knappa in masterkoden två gånger.
Vid första användningen används
masterkodens default-värde : 1 2 3 4 5.
Två pipsignaler bekräftar att man är i
programmeringsläget.
2. Knappa in AA.
En pipsignal hörs. Tryck 0för att avaktivera
ljudsignal vid knapptryckning.
Tryck 1för
att aktivera ljudsignal vid knapptryckning. En
pipsignal bekräftar den nya inställningen.
3. Tryck B för att lämna
programmeringsläget.
Två pipsignaler bekräftar att knappsatsen är
i standby-läge och är redo att användas.
J. Använding av de röda och gröna
LED-lamporna :
-De röda och gröna LED-lamporna har
integrerade motstånd och skall därför
anslutas till 12 VDC.
- De är kopplade på följande sätt:
OBS! Använd endast 12 VDC till LED-lamporna.
Orange
12 V DC
Grå
0 V
Rosa
12 V DC
Blå
0 V
2.2KΩ
2.2KΩ
Röd
LED
Grön
LED

Knappa in
masterkoden 2 gånger
Tidsinställning
bakgrunds-
belysning
10-99 sek
00=konstant
Tidsinställning
relä 1
01-99 sek
00 =
konstant
01=standard
Tidsinställning
relä 2
01-99 sek
00 =
konstant
01=standard
Kodlängd
4 eller 5 siffror
5 = standard
Masterkod
Ändra
masterkod
12345 =
standard
18 cdvi.se
cdvigroup.com
PROFIL100EC
Vattentätt kodlås med bakgrundsbelysning SV
INSTALLATION MANUAL
6] PROGRAMMERING
2 x pip
1 x pip
1 x pip = OK
4 pip = FEL
A0
1 x pip
1 x pip = OK
4 pip = FEL
A1
1 x pip
1 x pip = OK
4 pip = FEL
A2
1 x pip
1 x pip = OK
4 pip = FEL
A4
1 x pip
1 x pip = OK
4 pip = FEL
A5

2 pip
0 = Stäng av
ljudindikering
1 = Aktiverar
ljudindikering
Ljudindikering
Knappa först in
A sen B
Återställa
masterkod och
användarkod
2 siffror
AB = standard
Undermaster-
kod 1
2 siffror
13 = standard
Undermaster-
kod 2
Programmera
användarkoder
4 eller 5 siffror
4 pip = Upptagen
användarplats
1 pip = Ledig plats
19
cdvi.se
cdvigroup.com
PROFIL100EC
Vattentätt kodlås med bakgrundsbelysning SV
INSTALLATION MANUAL
6] PROGRAMMERING
Tryck B för att avsluta
programmeringen
1 x pip
1 x pip = OK
4 pip = FEL
AA
1 x pip
2 x pip = OK
A6
1 x pip
1 x pip = OK
4 pip = FEL
A7
1 x pip
1 x pip = OK
4 pip = FEL
A8
1 x pip = OK
00-99

20 cdvi.se
cdvigroup.com
PROFIL100EC
Vattentätt kodlås med bakgrundsbelysning SV
INSTALLATION MANUAL
Anteckningar - lista över användarkoder
Plats Kod Namn
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Reläutgång 1
Plats 00 till plats 59. Reläutgång 2
Plats 60 till plats 99.
PM
Plats Kod Namn
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
Plats Kod Namn
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
Other manuals for Digicode PROFIL100EC
1
Table of contents
Languages:
Other CDVI Keypad manuals

CDVI
CDVI GALEO/W User manual

CDVI
CDVI PROFIL 100 EC User manual

CDVI
CDVI PROFIL100EINT User manual

CDVI
CDVI Galeo User manual

CDVI
CDVI PROMI E Quick start guide

CDVI
CDVI SUBLIM User manual

CDVI
CDVI KCIENSBP User manual

CDVI
CDVI Digicode Series User manual

CDVI
CDVI PROFIL100EINT User manual

CDVI
CDVI GALEO BT User manual