Part No. ES150 - 121 - 0816
• Ensure any rebate strips or door stops are fitted before proceeding.
To enable the Electric strike to be located in the door frame, first
mark the position of the Door Latch front face on the door frame with the
door in the closed position.
• Mark where centre of latch meets door frame:
- For new installations, mark frame where front of latch touches
the door frame at the midpoint of the latch bolt.
- For retrofit installations, remove existing strike plate and ensure that
latch fits into and is centred in existing hole.
• Centrally locate the strike in the marked position, lining up both the
centre hole on the strike and the marked frame.
Position the strike hard up against the door frame.
• Hold the strike firmly in place and mark around the edge .
• Making sure the drill is perpendicular to the frame, drill three pilot holes
using the strike as a template.
Mark Centre of latch on
the door frame
Align the centre hole on the strike over the
marked line on the door frame.
33
4mm
• Using the markout as a guide, neatly chisel out the recess for the strike .
92mm
Small End of
Spring Short Pins
Long Pin
Short Pins
Long Pin
Power to Open
(Fail-Secure)
Fig 1
Power to Lock
(Fail-Safe)
Fig 2
To change electric strike’s mode of lock operation, remove brass screw
from top of strike body.
Invert strike and carefully release the small spring and 3 locking pins
(2 x Short pin, 1 x Long pin).
Re-insert pins in the manner shown for the desired mode of lock
operation (Power to Open / fail Secure): see Fig. 1; (Power to Lock / fail safe):
see Fig. 2, followed by replacing the spring. Screw in the brass screw to
strike body. This will secure the spring and locking pins.
ES150 SERIES ELECTRIC STRIKE
INSTALLATION INSTRUCTIONS
MARKING OF STRIKE POSITION POSITIONING OF STRIKE
MORTICING REBATE CHANGING MODE OF LOCK OPERATION
P/n
ASSA ABLOY Australia Pty Limited, 235 Huntingdale Rd, Oakleigh, VIC 3166 ABN 90 086 451 907 ©2016
Recommended 4mm Gap
Minimum 1mm Working Gap
• Once door frame preparation is complete, temporarily fit strike into
door frame to check for interference. Check that the door closes
smoothly and that the latch extends fully past the strike keeper.
• When strike operates correctly with latch, remove strike from
mortice and connect wiring.
• Refit strike and secure, making sure no wires are being crushed.
• Check both mechanical and electronic operation works correctly.
ELECTRICAL SPECIFICATION
CAUTION! - Incorrect supply voltage may cause damage not covered by warranty.
Please check supply voltage with a suitable meter to ensure it is within ± 15% of the nominal
voltage shown above with the strike powered.
DO NOT OIL OR LUBRICATE
24V DC 125mA 12V DC 250mA
Blue Red
Black
White
Blue
Red
White
Black •
• •
•
•
•
•
•
Blue and Black to Power Supply.
Red and White joined together.
Red and Black joined and to Power Supply.
Blue and White joined and to Power Supply.
•
•

Other Lockwood Lock manuals

Lockwood PADDE TRIMEC 200 Series User manual

Lockwood

Lockwood PADDE TRIMEC 200 Series User manual

Lockwood ST8011SSS User manual

Lockwood

Lockwood ST8011SSS User manual

Lockwood Digital Deadbolt User manual

Lockwood

Lockwood Digital Deadbolt User manual

Lockwood 3578 Series User manual

Lockwood

Lockwood 3578 Series User manual

Lockwood ASSA ABLOY Induro User manual

Lockwood

Lockwood ASSA ABLOY Induro User manual

Lockwood PADDE TRIMEC PRE-LOAD ES9000 Series User manual

Lockwood

Lockwood PADDE TRIMEC PRE-LOAD ES9000 Series User manual

Lockwood Nexion Classic User manual

Lockwood

Lockwood Nexion Classic User manual

Popular Lock manuals by other brands

Kaba LA GARD 2220 operating instructions

Kaba

Kaba LA GARD 2220 operating instructions

Westinghouse RTS Series Setup guide

Westinghouse

Westinghouse RTS Series Setup guide

Assa Abloy Yale Real Living YRD210-ZW Installation and programming instructions

Assa Abloy

Assa Abloy Yale Real Living YRD210-ZW Installation and programming instructions

Schlage S-480 user manual

Schlage

Schlage S-480 user manual

Siegenia GENIUS 2.2 Assembly instructions

Siegenia

Siegenia GENIUS 2.2 Assembly instructions

FSH EcoLock HL1260 installation manual

FSH

FSH EcoLock HL1260 installation manual

Baldwin 8225 Installation and user guide

Baldwin

Baldwin 8225 Installation and user guide

Hafele Sola operating instructions

Hafele

Hafele Sola operating instructions

AmazonBasics TRAVEL SENTRY B07T4J9MKQ quick start guide

AmazonBasics

AmazonBasics TRAVEL SENTRY B07T4J9MKQ quick start guide

Stock Loks C8714 instruction sheet

Stock Loks

Stock Loks C8714 instruction sheet

PDQ KMS STS pdqSMART Installation instruction

PDQ

PDQ KMS STS pdqSMART Installation instruction

INSYS CombiLock 200 simplex manual

INSYS

INSYS CombiLock 200 simplex manual

Sygonix UP IP66 operating instructions

Sygonix

Sygonix UP IP66 operating instructions

Nex-tech LA5095 user manual

Nex-tech

Nex-tech LA5095 user manual

Stock Loks CB-100 instruction sheet

Stock Loks

Stock Loks CB-100 instruction sheet

HMF 3503 instruction manual

HMF

HMF 3503 instruction manual

DMG SmartKEY installation manual

DMG

DMG SmartKEY installation manual

MeiTrack K211G user guide

MeiTrack

MeiTrack K211G user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.