Operation and Maintenance Instruction LNK-OM-LSL-3A&W / V2.2
6
4.2 Storage Temperature and Humidity Requirements
Storage temperature should be within -35℃~+65℃(-31°F~+149°F)and the environment
humidity should be less than 80%.
SECTION ⅤSERVICE LIFE &SAFETY
5.1 The life of LNK-LSL-3A and LNK-LSL-3AW lifejacket lights are five years from the date of
manufacture. During the service time the storage and application conditions meet the Section
Ⅳstorage requirements.
5.2 Once the light was been activated ,it can keep working for more than 10hrs at over 0.75
cd light intensity. After the battery will runs out, the light should be removed from the life jacket
and replaced by a new light.
5.3 LNK-LSL-3A and LNK-LSL-3AW lights contain Lithium batteries. These processes must be
handled correctly:
5.3.1 Do not replace the battery, Do not dismantle battery pack;
5.3.2 Do not make any external electrical connection;
5.3.3 Do not recharge;
5.3.4 Do not incinerate;
5.3.5 Store between -35℃~+65℃.
5.4 The LNK-LSL-3A and LNK-LSL-3AW lifesaving lights have potential electrostatic charging
hazard. Please avoid friction when used.
SECTION ⅥINSPECTION
6.1 Inspection Time
LNK-LSL-3A and LNK-LSL-3AW lifejacket lights should be inspected before installation or
regularly inspected together with lifejackets after installation.
6.2 Inspection Methods
6.2.1 Visually inspect the light for signs of damage or corrosion.
6.2.2 Test the light by immersing it in water, as the light should start flashing at once. And
manually pressing the switch on main body, and then the light can be turn off(LNK-LSL-3A)
or switch functions and turn off(LNK-LSL-3AW).
6.2.3 Remove the main body with water sensors from water and dry them, the light can be
turned off by manual switch, If press the switch again within 2 seconds it will be turn on again.
Otherwise it can`t be turn on manually, And must activated by water again.
6.2.4 If any defective appearance is found or not functioning well the light should be