LITHIUM CELLULAR & PLEATED MOTOR
Fitting & Operating Instructions
Low power consumption design, compatible with
7.4V battery box and solar panel.
Dot move and continuous move for option, free to
change the motor run direction.
Can set multiple limit positions(UP/DOWN/Middle
limit positions).
Position sensor open circuit and short circuit
protection function, stop on block function.
Can detect the circles of motor rotation, high
precision.
Automatic correction function for the displacement
caused by braking.
Power failure can save position and function
parameters.
PARAMETERS
KEY FEATURES
Model No. AM24B-06/34-ES-I-EB
Input Voltage
7.4V
Rated Torque 0.6Nm
Rated RPM 34 RPM
Rated Current 1.2A
Stall Current
2.5A
IP Class IP44
Control Mode
RF remote control /APP
Working Temperature
-10 ~ +60C°
Receiving Frequency
433.92MHz/2.4G
Modulation ASK/ Bluetooth
Receiving Distance ≥ 80m
MOTOR OVERVIEW
REMOTE LAYOUT
ADD REMOTE
SETTING UPPER LIMIT
SETTING THE MID POINT
SETTING LOWER LIMIT
1
2
4
3
R1940 - 1CH
Push button
LED CHANNEL
INDICATOR
UP
STOP
DOWN
R1942 - 6CH - WH
Push button
Also available in black
CHANNEL
BUTTON
LED CHANNEL
INDICATOR
UP
STOP
DOWN
R1944 - 16CH
Push button
CHANNEL
BUTTON
LED CHANNEL
INDICATOR
UP
STOP
DOWN
ON/OFF SET BUTTON
BATTERY
BACK OF
REMOTE
Plug motor into battery. Press and hold UP button until the remote oscillates. Press UP button for a second time and the
motor will oscillate. Remote is now paired.
Position blind to below desired top limit. Press SET button on the back of the remote, the motor will oscillate once and is
now in setting mode. Press and hold UP button to raise the blind to the desired upper limit position then press STOP. Press
SET button to conrm the upper limit, the motor will oscillate once. The upper limit position is now set.
Press DOWN button to the desired lower limit position then press STOP button. Press SET button on the remote, the
motor will oscillate once. Press SET button again and the motor will oscillate again setting the lower limit position.
Stop the blind at position to be added. Press SET button on the remote and the motor will oscillate. Press SET button
again and the motor will oscillate again adding mid point position.
*Setting upper and lower limit must be done in one operation.
JOG MODE
6
Press and hold STOP button on the remote until the motor oscillates. Press STOP button again, the motor will oscillate
again. The movement mode is changed. Repeat to exit jog mode.
Press and hold STOP button on the remote until the motor oscillates. Press DOWN button on the remote once, the motor
will oscillate again. The movement mode is changed.
Select channel to delete. Press and hold STOP button on the remote until the motor oscillates. Press SET button on the
remote until the motor oscillates again. The selected channels memory is now deleted.
Press and hold STOP button until the motor oscillates once. Press and hold SET button, the motor will oscillate once,
continue to hold until motor oscillates twice more. Motor has been factory reset.
CHANGE DIRECTION
7
DELETE SINGLE CHANNEL
8
FACTORY RESET
9Deleting all memory returns the motor back to factory settings.
FINE TUNING LIMIT POSITION
5
Send blind to position you wish to adjust. Press and hold SET button until motor oscillates. Press UP/DOWN buttons to
adjust the blind to the exact limit position. Press SET button again until the motor oscillates, ne tuning limit position is set.
09/22
FAQ SOLUTION
Power on, but motor not responding or
rotating slowly
Check the voltage is correct.
Check motor is installed correctly.
Check remote is paired.
The motor stops suddenly during
operation
Charge battery
Make sure the motor is not being overloaded.
DELETING LIMIT POSITIONS
10 The rst limit cannot be deleted separately, to remove this limit all limits must be deleted.
Let the motor run to the limit position which needs to be deleted. Press and hold SET button until the motor oscillates
once, continue to hold until the motor oscillates once more. The preset limit position is now deleted.

Other Louvolite Engine manuals

Louvolite R1912 User manual

Louvolite

Louvolite R1912 User manual

Louvolite Vertical Blind User manual

Louvolite

Louvolite Vertical Blind User manual

Louvolite R1905 User manual

Louvolite

Louvolite R1905 User manual

Louvolite R1705-RH User manual

Louvolite

Louvolite R1705-RH User manual

Louvolite R1912 User manual

Louvolite

Louvolite R1912 User manual

Louvolite R1710 Installation manual

Louvolite

Louvolite R1710 Installation manual

Louvolite R1725 Installation manual

Louvolite

Louvolite R1725 Installation manual

Popular Engine manuals by other brands

Jiecang JCC50STEW user manual

Jiecang

Jiecang JCC50STEW user manual

Nidec VR Series installation instructions

Nidec

Nidec VR Series installation instructions

Leuze electronic DCR 40 Original operating instructions

Leuze electronic

Leuze electronic DCR 40 Original operating instructions

Kohler Courage SV470 owner's manual

Kohler

Kohler Courage SV470 owner's manual

Weston UK WEST EUROTECH 52 T2 CURARE SPECIAL instructions

Weston UK

Weston UK WEST EUROTECH 52 T2 CURARE SPECIAL instructions

Bartec Varnost 5KTC 250 manual

Bartec Varnost

Bartec Varnost 5KTC 250 manual

Moog CD Series user manual

Moog

Moog CD Series user manual

Toshiba TB9051FTG manual

Toshiba

Toshiba TB9051FTG manual

Pentair HYPRO HM1C Product bulletin

Pentair

Pentair HYPRO HM1C Product bulletin

Kohler COMMAND CH15 owner's manual

Kohler

Kohler COMMAND CH15 owner's manual

Moki 100 BVT operating instructions

Moki

Moki 100 BVT operating instructions

Inel YYGL45E-20/15 operating instructions

Inel

Inel YYGL45E-20/15 operating instructions

MTU 12 V 4000 M63 operating instructions

MTU

MTU 12 V 4000 M63 operating instructions

Joy-it NEMA 23 manual

Joy-it

Joy-it NEMA 23 manual

SOMFY Oximo io instructions

SOMFY

SOMFY Oximo io instructions

Wilo EMU FA Installation and operating instructions

Wilo

Wilo EMU FA Installation and operating instructions

Siemens SIMOGEAR BA 2330 operating instructions

Siemens

Siemens SIMOGEAR BA 2330 operating instructions

Man D 2876 LE 201 Repair manual

Man

Man D 2876 LE 201 Repair manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.