Lynx C DX 5024 C User manual

Series 5000
© LYNX Technik AG
Brunnenweg 3
D-64331 Weiterstadt
Germany
www.lynx-technik.com
Reference Manual
C DX 5024 C
SDI to Analog Audio & Video Converter
CardModul
e
Version 2.0

Reference Manual C DX 5024 C Version 2.0
Page 2
Information in this document is subject to change without
notice. No part of this document may be reproduced or
transmitted in any form or by any means, electronic or
mechanical for any purpose, without express written permission
of LYNX Technik AG.
LYNX Technik AG may have patents, patent applications,
trademarks, copyrights or other intellectual property rights
covering the subject matter in this document. Except as
expressly written by LYNX Technik AG, the furnishing of this
document does not give you any license to patents,
trademarks, copyrights or other intellectual property of LYNX
Technik AG or any of its affiliates.
© LYNX Technik AG 2007 all rights reserved

Reference Manual C DX 5024 C Version 2.0
Page 3
Warranty
LYNX Technik AG warrants that the product will be free from
defects in materials and workmanship for a period of two (2)
year from the date of shipment. If this product proves defective
during the warranty period, LYNX Technik AG at its option will
either repair the defective product without charge for parts and
labor, or will provide a replacement in exchange for the
defective product.
In order to obtain service under this warranty, customer must
notify LYNX Technik of the defect before expiration of the
warranty period and make suitable arrangements for the
performance of service. Customer shall be responsible for
packaging and shipping the defective product to the service
center designated by LYNX Technik, with shipping charges
prepaid. LYNX Technik shall pay for the return of the product to
the customer if the shipment is within the country which the LYNX
Technik service center is located. Customer shall be responsible
for payment of all shipping charges, duties, taxes and any other
charges for products returned to any other locations.
This warranty shall not apply to any defect, failure, or damage
caused by improper use or improper or inadequate
maintenance and care. LYNX Technik shall not be obligated to
furnish service under this warranty a) to repair damage resulting
from attempts by personnel other than LYNX Technik
representatives to install, repair or service the product; b) to
repair damage resulting from improper use or connection to
incompatible equipment; c) to repair any damage or
malfunction caused by the use of non LYNX Technik supplies; or
d) to service a product which has been modified or integrated
with other products when the effect of such modification or
integration increases the time or difficulty servicing the product.
THIS WARRANTY IS GIVEN BY LYNX TECHNIK WITH RESPECT TO THIS
PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR
IMPLIED. LYNX TECHNIK AND ITS VENDORS DISCLAIM ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. LYNX TECHNIK`S RESPONISIBILITY TO REPAIR AND
REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE
REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS
WARRANTY. LYNX TECHNIK AND ITS VENDORS WILL NOT BE LIABLE
FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTAL
DAMAGES IRRESPECTIVE OF WHETHER LYNX TECHNIK OR THE
VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH
DAMAGES.

Reference Manual C DX 5024 C Version 2.0
Page 4
Regulatory information
Europe
Declaration of Conformity
USA
FCC 47 Part 15
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Note: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to the part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own
expense
We LYNX Technik AG
Brunnenweg 3
D-64331 Weiterstadt
Germany
Declare under our sole responsibility that the product
TYPE: C DX 5024 C
To which this declaration relates is in conformity with the following
standards (environments E1-E3):
EN 55103-1 /1996
EN 55103-2 /1996
EN 60950 /2001
Following the provisions of 89/336/EEC and 73/23/EEC directives.
Winfried Deckelmann
Weiterstadt, March 2007
Place and date of issue Legal Signature

Reference Manual C DX 5024 C Version 2.0
Page 5
Contents
Warranty ...................................................................................3
Regulatory information............................................................4
Europe...............................................................................................4
Declaration of Conformity ...........................................................4
USA ..................................................................................................4
FCC 47 Part 15.............................................................................4
Contents ...................................................................................5
Getting Started.........................................................................7
Packaging..........................................................................................7
Product Description ..........................................................................7
Functional Diagram ..........................................................................9
Module Layout..................................................................................9
Connections...........................................................................11
Video Connections..........................................................................11
Audio Connections .........................................................................12
Audio Output Connections (balanced).......................................12
Installation ..............................................................................13
Link Settings...................................................................................14
Balanced / Unbalanced Audio....................................................14
Settings and Control ..............................................................14
Multi Function Switch ....................................................................15
Using the Local Display Menus......................................................16
Navigation..................................................................................16
Local Adjustments Available.....................................................16
Menu Structure ...............................................................................17
Auto Store ..................................................................................17
Factory Preset Condition............................................................18
Alarm/LED Status Indicators..........................................................24
SDI Status Indicator...................................................................24
AES Status Indicator..................................................................24
Alarm Indicator..........................................................................24
Locate Function .........................................................................25
Specifications (C DX 5024 C)................................................26
Available Options ..................................................................27
Parts List...................................................................................27
Service ....................................................................................28
Contact Information ..............................................................29

Reference Manual C DX 5024 C Version 2.0
Page 6
This page is intentionally left blank

Reference Manual C DX 5024 C Version 2.0
Page 7
Getting Started
Packaging
The shipping carton and packaging materials
provide protection for the module during transit.
Please retain the shipping cartons in case
subsequent shipping of the product becomes
necessary.
Product Description
The C DX 5024 C is a high quality Audio de-
multiplexer and Audio and Video D to A Converter
primarily for broadcast and professional
applications.
The Module accepts 1 SDI input signal with up to
four audio groups embedded. One audio group
can be selected and de-multiplexed and output as
4 x balanced analog audio signals and in parallel
as 2 x AES3 signals on a Sub D connection. Three re-
clocked outputs of the input signal are provided to
cascade several modules to de-embed further
audio groups if required.
The SDI inputs signal is converted to analog video
as CVBS, YC (S-Video) or Component outputs.
The C DX 5024 has a variety of features, which
include:
•User selectable audio group (I through 4)
•525/625 line standards (Auto detect)
•Two reclocked outputs of input video
•Supports 8 and 10 bit video
•Analog and Digital Audio outputs
•24 bit audio
•Adjustable 0 dB FS level
•Analog Video Outputs (CVBS, YC, Component)
•10 Bit Video DA conversion
•Local DIP-switches and LED's for control and
status monitoring
•Microprocessor controlled
•Remote control interface
•All settings stored in non-volatile flash ram

Reference Manual C DX 5024 C Version 2.0
Page 8
The module has a built in micro-controller with local
controls, status and alarm indicators and well as
internal flash ram for storing setups. Any operational
parameters configured and stored into the module
are recalled when powered up. Remote control
and remote status monitoring is possible when used
with the rack frame option and host controller.
CardModules are installed in the series 5000 card
frame (R FR 5010) that can accommodate up to 10
CardModules. All modules are hot swappable and
Options include full redundant power and a range
of controller options.

Reference Manual C DX 5024 C Version 2.0
Page 9
Functional Diagram
Figure 1 below is the basic functional diagram for
the C DX 5024 C CardModule.
Figure 1- C DX 5024 C Functional Diagram
Module Layout
Figure 2 shows the physical layout of the C DX 5024
C CardModule and also the connection panel that
is fitted to the rear of the rack.

Reference Manual C DX 5024 C Version 2.0
Page 10
Figure 2 – Module Layout

Reference Manual C DX 5024 C Version 2.0
Page 11
Caution
Use static precautions when handling the
PCB. Static discharge could result in serious
damage to the module.
Connections
Video Connections
The C DX 5024 C CardModule is configured with
standard 75 Ohm BNC connectors. Connection is
self-explanatory. We recommend the use of high
quality video cable for digital video connections to
reduce the risk of interference or errors due to
excessive cable attenuation. Some guidelines for
max cable length are shown below.
250m (820 feet) Belden 8281 (270Mbits/s)
Note. Due to the compact design of the
connection plate it will be necessary to use a
connection tool to secure the BNC video
connectors.

Reference Manual C DX 5024 C Version 2.0
Page 12
Audio Connections
Audio Output Connections (balanced)
SubD 25 pin female connector.
Figure 3 - Audio output connection detail
Pin
Number Connection Pin
Number Connection
1 + Left 1 14 - Left 1
2 GND Left 1 15 + Right 1
3 - Right 1 16 GND Right 1
4 + Left 2 17 - Left 2
5 GND Left 2 18 + Right 2
6 - Right 2 19 GND Right 2
7 + AES 1 20 - AES 1
8 GND AES 1 21 + AES 2
9 - AES 2 22 GND AES 2
10 23
11 24
12 25
13
113
1425

Reference Manual C DX 5024 C Version 2.0
Page 13
Installation
Caution
The CardModule is shipped in a
protective anti-static bag. Please take
suitable precautions to avoid static
discharge onto any part of the PCB or
components when handling module or
serious damage could result.
Each Card Module is supplied with a rear
connection panel and two mounting screws.
Please follow the following procedure for
installation of the card module into the Series 5000
Card Frame.
a) Select a slot in the card frame where the
CardModule will be located
b) Remove the blank connection panel from the
rear of the rack (if fitted)
c) Install the rear connection panel using the
screws supplied. Do not tighten the screws fully
d) Slide the card module into the card frame and
carefully check the CardModule easily
connects to the rear connection plate. The
card should fit easily and should not require
excessive force to insert, if you feel any
resistance, there could be something wrong
with the rear connection panel location. Do not
try and force the connection. Remove the rear
connection panel and check alignment with
the CardModule.
e) Insert and remove the CardModule a few times
to ensure correct alignment and then tighten
the two screws to secure the rear connection
plate

Reference Manual C DX 5024 C Version 2.0
Page 14
Link Settings
Balanced / Unbalanced Audio
It is possible to set the analog audio outputs to
balanced or unbalanced with automatic gain
adjustment.
This is done using physical links on the card and the
card will need to be removed from the card frame
for changes to be made*. Figure 2 shows the
locations.
Link open = Audio balanced
Link closed = Audio unbalanced
(with automatic gain adjustment)
If the respective link is closed the “-“ pin of the
audio output is set to ground.
*Note. It is not necessary to power down the frame
to remove the card. All Series 5000 Card Modules
can be hot plugged / unplugged.
Settings and Control
The C DX 5024 C has an integrated micro-
controller, which enables the module to be
configured and controlled locally using the
multifunction switch and 4 character dot matrix
display, or from remote when using one of the
optional controllers and control software.
Once set, all settings are automatically saved in
non-volatile internal memory. (Flash ram) The
module will always recall the settings used prior to
power down.

Reference Manual C DX 5024 C Version 2.0
Page 15
Multi Function Switch
The CardModule is equipped with a multi-function
switch located on the front bottom edge of the
card (refer to figure 2)
Figure 3 – Switch Operation
Up Down Enter
Switch Operations
Multi-function Switch
Side Front

Reference Manual C DX 5024 C Version 2.0
Page 16
Using the Local Display Menus
Making local adjustments to the module is done
using the multifunction switch and the integrated 4-
character dot matrix display (figure 3). The menu
system is layered, and navigation through the
system is done using the UP and DOWN functions of
the switch. ENTER is used to move between menu
levels and also enter a selection.
Navigation
Local Adjustments Available
All of the critical adjustments to the module are
accessible using the local display and multi -
function switch.
Switch Function Operation
UP Move UP within a level
DOWN Move down within a level
ENTER Change levels / Make selection

Reference Manual C DX 5024 C Version 2.0
Page 17
Menu Structure
The Menu structure is defined in the next table, and
should be used when navigating through the
system.
Notes / Tips.
ENTER moves between Levels
UP/DOWN moves between items within the level
When you enter a new setting the system will jump
back one level in the menu system.
The “back” selection in the menu structure will take
you back one level when selected.
When an item is selected which has several setting
possibilities the first value displayed will be the value
currently stored in the system. The order of the
available settings for any menu item in the table
supplied does not represent the order he settings
will actually be displayed.
If left unattended, the menu will default to the root
display after a preset timeout.
Auto Store
If no parameters are changed for 10 seconds then
the current settings will be written into flash memory
automatically, this can be seen by the alarm LED
flashing yellow four times.

Reference Manual C DX 5024 C Version 2.0
Page 18
Factory Preset Condition
The C DX 5024 C is delivered preset for the following
mode of operation:
•Audio Group 1 selected
•Full Scale Level 15dBu (analog Audio)
•Video Output Component
•Test Signal Off
If this is the mode of operation required, then no
adjustments are necessary.

Reference Manual C DX 5024 C Version 2.0
Page 19

Reference Manual C DX 5024 C Version 2.0
Page 20
Table of contents
Other Lynx Media Converter manuals

Lynx
Lynx MiniModules 3000 Series User manual

Lynx
Lynx C AD 5110 User manual

Lynx
Lynx C DA 5010 User manual

Lynx
Lynx C AD 5111 User manual

Lynx
Lynx P AR 5610 User manual

Lynx
Lynx C AD 3321 D User manual

Lynx
Lynx Aurora User manual

Lynx
Lynx hilo User manual

Lynx
Lynx C DX 5624 User manual

Lynx
Lynx C AD 3110-2 User manual

Lynx
Lynx CardModule C AD 5131 User manual

Lynx
Lynx D AD 3260 BS User manual

Lynx
Lynx hilo User manual

Lynx
Lynx greenMachine HDR Static User manual

Lynx
Lynx C DA 5005 User manual

Lynx
Lynx P VD 5660 D User manual

Lynx
Lynx C AD 3100 User manual

Lynx
Lynx C AD 5320 D User manual

Lynx
Lynx Hilo Preliminary User manual

Lynx
Lynx yellobrik CDH 1813 User manual