47LT
P. 2 / 9ES-9512 Rev.1
INSTALLATION
Power input
AC: Operational voltage range 85 – 264V
50/60 Hz, approx. 6.5VA
DC: Operational voltage range 24V ±10%
ripple 10% p-p max.; approx. 3W
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90% RH (non-condensing)
Mounting: Panel flush mounting
Panel cutout: W92×H45 mm (3.62”×1.77”)
Panel thickness: 1.6 – 8.0 mm (0.06” – 0.31”)
Dimensions: W96×H48×D98.5 mm (3.78”×1.89”×3.88”)
Weight: 300 g (0.66 lbs)
PERFORMANCE in percentage of max. span
Accuracy
Display: ≤±1°C ±1 digit (PR, K, E, J, T)
≤±2°C ±1 digit (B, R, S, N)
Minimum display scale 1°C or 1°F (0.1°C for
K and J, narrow span)
Output: ≤±0.15% (DC output = display + output)
Cold junction compensation error:
±3°C maximum at 25 ±10°C
±5.4°F maximum at 77 ±18°F
Temp. coefcient: ≤±0.015%/°C (≤±0.008%/°F) when the
input range is set to the maximum span.
Input resolution: Max. 16 bits
Output resolution: Max. 13 bits
Response time: ≤0.5 second
(alarm output: 0 – 100% at 90% setpoint)
≤0.5 second (DC output: 0 – 90%)
Burnout response: ≤15 seconds
Line voltage effect: ±0.1% over voltage range
Insulation resistance: ≥100MΩ with 500V DC
Dielectric strength: 2000V AC @1 minute (input to DC
output to HH output or H output to L output
or LL output to power to ground)
INPUT & OUTPUT
■ THERMOCOUPLE
Input resistance: 1MΩ minimum
Burnout sensing: ≤0.1µA
■ DC OUTPUT
• DC Current
Operational range: -5 – +105%
Load resistance
(Range) 4 – 20mA : 550 (Ω maximum)
0 – 20mA : 550
• DC Voltage
Operational range: -5 – +105%
Load resistance
(Range) 0 – 10V : 10k (Ω minimum)
-10 – +10V : 10k
0 – 5V : 5000
1 – 5V : 5000
■ ALARM OUTPUT: Relay contact
Rated load: 250V AC @3A (cosø=1)
30V DC @3A (resistive load)
Electrical life ≥105cycles (rate 6 cycles/min.)
Maximum switching voltage: 250V AC, 30V DC
Maximum switching power: 750VA, 90W (resistive load)
Minimum load: 5V DC @10mA
Mechanical life: ≥5 ×106cycles (rate 180 cycles/min.)
Temperature Range
THERMOCOUPLE
CONFORMANCE
USABLE
RANGE RANGE
(PR) °C 0 to 1700 -30 to +1730
°F 32 to 3092 -22 to +3146
K(CA) °C -200 to +1300 -230 to +1330
°F -328 to +2372 -382 to +2426
K(CA), narrow span °C -100.0 to +450.0 -199.9 to +500.0
E(CRC) °C 0 to 600 -30 to +630
°F 32 to 1112 -22 to +1166
J(IC) °C -100 to +850 -130 to +880
°F -148 to +1562 -202 to +1616
J(IC), narrow span °C -100.0 to +350.0 -150.0 to +400.0
T(CC) °C -200 to +400 -230 to +430
°F -328 to +752 -382 to +806
B(RH) °C 400 to 1800 70 to 1830
°F 752 to 3272 158 to 3326
R °C 200 to 1700 -30 to +1730
°F 392 to 3092 -22 to +3146
S °C 0 to 1700 -30 to +1730
°F 32 to 3092 -22 to +3146
N °C -200 to +1300 -230 to +1330
°F -328 to +2372 -382 to +2426