manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Surge Protector
  8. •
  9. M-system MDCAT 5E User manual

M-system MDCAT 5E User manual

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8139 Rev.4 P. 1 / 4
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Surge protector....................................................................(1)
LAN cable ............................................................................(1)
Single mount DIN rail ........................................................(1)
(Only for option code ‘/DR’ selected)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
LIMITATION APPLICABLE TO M-RESTER
The M-RESTER will protect electronics equipment from
damage caused by lightning by absorbing most of the
surge voltages.
However, M-RESTER may not be effective against cer-
tain extremely high voltages caused by a direct or almost
direct hit by lightning.
M-RESTER must be installed according to this installa-
tion / instruction manual.
POINTS OF CAUTION
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the surge protector inside proper housing with
sufficient ventilation.
• Do not install the surge protector where it is subjected to
continuous vibration. Do not subject the unit to physical
impact.
• Environmental temperature must be within -25 to +85°C
(-13 to +185°F) with relative humidity within 30 to 90%
RH in order to ensure adequate life span and operation.
• This unit can be earthed via a DIN rail. Oxide film on the
surface of an aluminum rail may lower the electric con-
ductivity between this module and the ground. When this
unit is earthed via a DIN rail, use a steel or copper rail.
• Steel rails may be coated with thin oxide film. Discharg-
ing surge current may produce sparks with the film.
However, this does not affect the surge protection. If you
need to avoid sparks, prior to mounting on the DIN rail,
remove the film by a wire brush.
• Single mount DIN rail for option code ‘/DR’ is made of alu-
minum. Connect to ground with ground terminal when
this DIN rail is used.
■AND ....
• We recommend that you keep spare surge protectors so
that you can replace them when necessary.
• Lightning surge can enter not only through signal lines
but also through power supply lines. We recommend that
you also use the surge protectors for power line for suf-
ficient protection.
COMPONENT IDENTIFICATION
MODULAR JACK,
SURGE SIDE
Body
Specifications
SHORTCIRCUIT BAR
MODULAR JACK,
PROTECTED SIDE
DIN rail adaptor
SHIELD TERMINAL
EARTH TERMINAL
Side (hidden)
INSTALLATION
Mount the unit on a DIN rail. Once installed, do not move
it to another DIN rail.
■MOUNTING THE UNIT ON A DIN RAIL
A)Hang the upper hook of the DIN rail mounting adaptor at
the rear side of unit, on the DIN rail.
B)Push in the lower in keeping pressing the unit to the DIN
rail.
DIN Rail
B
A
■REMOVING THE UNIT
A)Pull down the DIN rail adaptor utilizing a minus screw-
driver.
B)Pull out the lower part of the unit.
C)Detach the upper part from the DIN rail.
CB
A
DIN rail adaptor
LIGHTNING SURGE PROTECTOR FOR ETHERNET
(PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) MODEL MDCAT
MDCAT
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8139 Rev.4 P. 2 / 4
GENERAL
■FUNCTION & FEATURES
• Designed specifically for Ethernet network
• Conforms with 1000 Base-T, PoE and PoE Plus
• LAN cable’s shield wire can be floating or grounding by a shortcircuit bar
• DIN rail mounting
■SPECIFICATIONS
LINE TO LINE (pair) LINE
TO
LINE (PoE)
LINE
TO
EARTH
MDCAT-5E MDCAT-6
Max. continuous operating voltage (Uc) ±6V ±3.3V ±58V ±150V
Voltage protection level (Up) ±15V @2kV ±10V @2kV ±100V @2kV ±600V @4kV
Leakage current @Uc 25µA 5µA 25µA 5µA
Response time ≤ 4 nsec. ≤ 4 nsec. ≤ 4 nsec. ≤ 20 nsec.
Max. discharge current (Imax) 100A 100A 100A 10kA
Nominal current (IN) 1A
Series resistance Approx. 0Ω
Transmission performance: TIA/EIA-568-B.2
CAT5e (MDCAT-5E)
CAT6 (MDCAT-6)
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
90 (3.54)3.5 (.14)
[3 (.12)]
40 (1.57)
MODULAR JACK,
SURGE SIDE
MODULAR JACK,
PROTECTED SIDE
DIN RAIL
(35mm wide)
• When mounting, no extra space is needed between units.
SHORTCIRCUIT BAR
SHIELD TERMINAL (SHLD)
EARTH TERMINAL (G)
35 (1.38)38 (1.50)
2-M3 SCREW
6 (.24) [4.5 (.18) deep]
11
(.43)
50 (1.97)
4.2 (.17)
35 (1.38)
7.3 (.29)
■UNIT
■DIN RAIL
MDCAT
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8139 Rev.4 P. 3 / 4
■CONNECTION DIAGRAM
■ PROTECTING STP DEVICE
*
3
*
3
■ PROTECTING NON-STP (UTP) DEVICE
MDCAT (Protected Device)
Crossover Wire
FG
*
2
*
7
*
5
*1. Unshield twisted-pair cable
*2. Maintain the shortcircuit bar. The protected device is earthed.
*3. Cable included in the product package or provided by customer.
*4. Shield twisted-pair cable
*5. STP cable’s shield wire serves as the crossover wiring.
*6. The protected device is ‘earthed’ when the shortcircuit bar is connected. Remove the bar in order to switch to ‘floating’ state.
*7. Use a DIN rail made of steel or copper when connecting to ground via the DIN rail.
Single mount DIN rail for option code ‘/DR’ is made of aluminum.
Connect to ground with ground terminal when this DIN rail is used.
MDCAT (Protected Device)
FG
*
6
*
7
SHLD
G
SHLD
G
UTP Cable
*
1
STP Cable
*
4
■NETWORK CONNECTION EXAMPLE
Hub / Switch
Server
Protocol
Converter
Remote I/O
Remote I/O
Router
MDCAT
PC
Open Field Network Network Camera
MDCAT
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8139 Rev.4 P. 4 / 4
MAINTENANCE
Check surge protectors periodically. Many cases of lightning are ignored, and even lightning at a far distance often causes
inductive surges.
We recommend that you check your surge protector about twice a year, before and after the rainy season. Check whenever
you experience a strong lightning occurrence.
Checking procedure is explained in the following:
■CHECKING
WIRING
• Make sure that wiring is done as instructed in the connection diagram.
DISCHARGE ELEMENT
Approximate checking can be conducted as following.
1) Remove all LAN cables connected to the MDCAT.
2) Remove also the shortcircuit bar.
3) Connect between the surge side modular jack and a modular jack type rosette with a LAN cable and remove the rosette’s
cover to expose its connecting pines.
Modular Jack Type Rosette
(Harmonet HLA-T-MJ-8)
(1)
(2)
(3)
(4)
(8)
(6)
(7)
(5)
GSHLD
4) Shortcircuit Test
Check resistance across the following terminals on the high resistance range of multimeter and confirm no conduction.
(The meter will indicate the same value as it will show when these terminals are open.)
SHLD – G
Then, apply ±6V DC (for MDCAT-5E) or ±3.3V DC (for MDCAT-6) across the following terminals and measure leakage cur-
rent to show ≤ 25μA (for MDCAT-5E) or ≤ 5μA (for MDCAT-6). If a voltage generator is not available, check resistance with
a multimeter and confirm no conduction. (Use of a voltage generator is strongly recommended.)
Rosette pins (1) – (2), (3) – (6), (4) – (5), (7) – (8)
Then, apply ±58V DC across the following terminals and measure leakage current to show ≤ 5µA. If a voltage generator is
not available, check resistance with a multimeter and confirm no conduction. (Use of a voltage generator is strongly recom-
mended.)
Rosette pins (1) – (3), (2) – (6), (4) – (7), (5) – (8)
5) Discharging Test
Check that discharging occurs across the following terminals with a ±500V DC 1000 MΩ insulation tester.
(The tester shows ≤ 20MΩ.)
Each rosette pin of (1) through (8) – G, SHLD – G

This manual suits for next models

2

Other M-system Surge Protector manuals

M-system MDP-PM User manual

M-system

M-system MDP-PM User manual

M-system MDP-PA User manual

M-system

M-system MDP-PA User manual

M-system MD7JS User manual

M-system

M-system MD7JS User manual

M-system MD7ST User manual

M-system

M-system MD7ST User manual

M-system MGA-100 User manual

M-system

M-system MGA-100 User manual

M-system MDK-LC User manual

M-system

M-system MDK-LC User manual

M-system MDP-100T User manual

M-system

M-system MDP-100T User manual

M-system MDP-D Series User manual

M-system

M-system MDP-D Series User manual

M-system MD7LC User manual

M-system

M-system MD7LC User manual

M-system MMH-1 User manual

M-system

M-system MMH-1 User manual

M-system MATP User manual

M-system

M-system MATP User manual

M-system MDR2 User manual

M-system

M-system MDR2 User manual

M-system MDCAT-SPE-A User manual

M-system

M-system MDCAT-SPE-A User manual

M-system MDP-JS User manual

M-system

M-system MDP-JS User manual

M-system MDCAT-SPE User manual

M-system

M-system MDCAT-SPE User manual

M-system MDP-TL User manual

M-system

M-system MDP-TL User manual

M-system MDP-SP User manual

M-system

M-system MDP-SP User manual

M-system MAKN User manual

M-system

M-system MAKN User manual

M-system MDK-24 User manual

M-system

M-system MDK-24 User manual

M-system MH-1201 User manual

M-system

M-system MH-1201 User manual

M-system MGD-24 User manual

M-system

M-system MGD-24 User manual

M-system MDPA-24 User manual

M-system

M-system MDPA-24 User manual

M-system MD-LC2 Service manual

M-system

M-system MD-LC2 Service manual

M-system MDP-100 User manual

M-system

M-system MDP-100 User manual

Popular Surge Protector manuals by other brands

novaris CN-FF-zz-3-E installation instructions

novaris

novaris CN-FF-zz-3-E installation instructions

Emos P54212 user manual

Emos

Emos P54212 user manual

Patton electronics 536S user manual

Patton electronics

Patton electronics 536S user manual

Phoenix Contact TERMITRAB complete Technical notes

Phoenix Contact

Phoenix Contact TERMITRAB complete Technical notes

Ilsco SSI SpecPRO SRM 3 Series manual

Ilsco

Ilsco SSI SpecPRO SRM 3 Series manual

Sven Fort user manual

Sven

Sven Fort user manual

SNAP Episode EP-300-9HTR Manual instructions

SNAP

SNAP Episode EP-300-9HTR Manual instructions

Ilsco SSI SpecPRO SSM 28 Series manual

Ilsco

Ilsco SSI SpecPRO SSM 28 Series manual

Emerson SolaHD STC-HSP Series manual

Emerson

Emerson SolaHD STC-HSP Series manual

brennenstuhl Primera-Tec Comfort Switch Plus 19.500 A operating instructions

brennenstuhl

brennenstuhl Primera-Tec Comfort Switch Plus 19.500 A operating instructions

AccelTex ATS-SS-70V-5KA-1GBPS-AT installation guide

AccelTex

AccelTex ATS-SS-70V-5KA-1GBPS-AT installation guide

Eaton Crouse-Hinds SD Series Safety manual

Eaton

Eaton Crouse-Hinds SD Series Safety manual

Energenie SPF5-C-5 user manual

Energenie

Energenie SPF5-C-5 user manual

Siemens 5SD7 498-3 operating instructions

Siemens

Siemens 5SD7 498-3 operating instructions

Superior Electric STABILINE DIN3-70 Series owner's manual

Superior Electric

Superior Electric STABILINE DIN3-70 Series owner's manual

Sven SF-05 user manual

Sven

Sven SF-05 user manual

Asco Series 300 Installation & operation manual

Asco

Asco Series 300 Installation & operation manual

ROBOfiber TSP-101-DIN quick start guide

ROBOfiber

ROBOfiber TSP-101-DIN quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.