MP-RFC Instruction Sheet
2 ©2015 Sensata Technologies
Figure 3, MP-RFC Installation
Figure 4, Attaching the Router to the MP-RFC
Step A Step B Step C
MP-RFC
Truss head
screws (x4)
Front cover
screws (x8)
Installation
1. Remove the eight screws that hold the front cover to the MP
enclosure (Step A below).
2. Remove the four truss head screws (Step B below) that secure
the top cover to the front cover.
3. Replace the top cover with the MP-RFC (Step C below), and
re-attach to the front cover with the four truss head screws
removed in Step 2.
4. Attach the router to the MP-RFC (Figure 4) using the four
supplied screws (8-32 x 1/2 Phillips screws).
5. Route any stacking/communication cables from the enclosure
through the existing spaces in the MP-RFC and connect to the
attached router. Note: With some installations, it may be easier
to connect the cables prior to attaching the ME-RTR (router).
6. Using the same eight screws that were removed when detaching
the front cover (Step 1), secure the front cover to the enclosure.
7. Attach the bezel cover to the router.