4. Safety instructions and warnings
Exercise caution when handling
packaging materials. Observe
applicable safety and accident prevention
requirements. Store packaging material out of
the reach of children (risk of suffocation).
A fan that is not mounted correctly
may result in non-intended operation
or impermissible operation. Only install fan
in accordance with the planning documents.
In particular, note the information on
ventilation channels and sound insulation.
Observe planning instructions regarding unit
position and distances to other façade
components. If necessary, use isolating
elements.
Risks from parts which may affect
the ventilation system which are
added or modified at a later date. Parts
(range hood, air-ventilated fireplace etc.)
which are added or modified at a later date
may result in health risks and operation which
is not permitted. Parts may only be added or
modified at a later date if system compatibility
is established/ensured by a planning office. If
using an exhaust air range hood or air-
ventilated fireplace, this must be accepted by
a regional master chimney sweep.
Danger from operating with the fan
not fully mounted. Electric
components are a potential source of
electric shock. If the unit is open, all off the
supply circuits must be switched off (mains
fuse off), secured against being accidentally
switched back on and a visible warning sign
positioned. Only operate the fan when it is
completely installed.
Risk of injury and health risk in the
event of changes or modifications or
if components which are not permitted are
used. The unit may only be operated with
original components. Changes and
modifications to the units are not permitted
and release the manufacturer from any
guarantee obligations and liability, e.g. if the
housing is drilled at a point which is not
permitted.
Danger if the relevant regulations for
electrical installations are not
observed.
●Before removing the housing cover or
removing the fan insert and before
installing the electrics, switch off all supply
circuits and secure them against being
accidentally switched back on again.
Attach a warning sign in a clearly visible
place.
●Be sure to observe the relevant regula-
tions for electrical installation; e.g. DIN EN
50110-1. In Germany, particularly observe
VDE 0100, with the corresponding sections.
●A mains isolation device with contact
openings of at least 3 mm at each pole is
mandatory.
●Only connect unit to permanently wired
electrical installation and with NYM-O or
NYM-J cables, depending on the unit
variant, 3 x 1.5 mm² or 5 x 1.5 mm².
●The units may only be operated using the
voltage and frequency shown on the rating
plate.
●Unit may also be energized even when at
a standstill and may be switched on
automatically by sensors (time delay,
humidity etc.). Maintenance and fault
finding only permissible when carried out
by trained electricians.
●The degree of protection stated on the
rating plate is only guaranteed if
installation is undertaken correctly and if
the connecting cable is correctly guided
through the stepped grommet (The
grommet must completely enclose the
cable sheathing). The fan insert must also
be engaged and the housing cover
installed.