4.1 Calibration
To maintain the integrity of measurements made using your
instrument, Martindale Electric recommends that it is returned at
least once a year to an approved Calibration Laboratory for
recalibration and certification.
Martindale Electric is pleased to offer you this service. Please
contact our Service Department for details.
Email: service@martindale-electric.co.uk
Tel: 01923 650660
4.5 Cleaning
The unit may be cleaned using a soft dry cloth. Do not use
moisture, abrasives, solvents, or detergents, which can be
conductive.
4.6 Repair & Service
There are no user serviceable parts in this unit other than those
that may be described in section 3. Return to Martindale Electric if
faulty. Our service department will quote promptly to repair any
fault that occurs outside the guarantee period.
Before the unit is returned, please ensure that you have checked
the unit, batteries, fuses, poor connections and leads.
4.7 Storage Conditions
The instrument should be kept in warm dry conditions away from
direct sources of heat or sunlight, and in such a manner as to
preserve the working life of the unit. It is strongly advised that the
unit is not kept in a tool box where other tools may damage it.
10
5. WARRANTY AND LIMITATION OF LIABILITY
This Martindale product is warranted to be free from defects in
material and workmanship under normal use and service. The
warranty period is 2 years and begins on the date of receipt by the
end user. This warranty extends only to the original buyer or end-
user customer, and does not apply to fuses, disposable batteries,
test leads or to any product which, in Martindale’s opinion, has
been misused, altered, neglected, contaminated, or damaged by
accident or abnormal conditions of operation, handling or storage.
Martindale authorised resellers shall extend this warranty on new
and unused products to end-user customers only but have no
authority to extend a greater or different warranty on behalf of
Martindale.
Martindale's warranty obligation is limited, at Martindale's option,
to refund of the purchase price, free of charge repair, or
replacement of a defective product which is returned to Martindale
within the warranty period.
This warranty is the buyer’s sole and exclusive remedy and is in
lieu of all other warranties, expressed or implied, including but not
limited to any implied warranty of merchantability or fitness for a
particular purpose. Martindale shall not be liable for any special,
indirect, incidental or consequential damages or losses, including
loss of data, arising from any cause or theory.
Since some jurisdictions do not allow limitation of the term of an
implied warranty, or exclusion or limitation of incidental or
consequential damages, the limitations and exclusions of this
warranty may not apply to every buyer. If any part of any provision
of this warranty is held invalid or unenforceable by a court or other
11
12
decision-maker of competent jurisdiction, such holding will not affect
the validity or enforceability of any other provision or other part of
that provision.
Nothing in this statement reduces your statutory rights. ELECTRICAL
All specified accuracies are at 23°C ± 5°C,
<75% RH for 1 year.
Temperature coefficient: 0.1 x (specified
accuracy) per °C (0°C to 18°C, 28°C to 50°C)
DC VOLTAGE
Ranges: 200mV, 2000mV, 20V, 200V, 600V
Resolution: 200mV, 2000mV, 20V, 200V, 600V
Accuracy: ± (0.5% of rdg + 1 dgt)
Input impedance: 10MΩ
Overload protection: 600V DC or AC rms
600V DC or AC rms for 15 seconds on 200 mV
range
AC VOLTAG E (50Hz to 500Hz)
Ranges: 200mV, 2000mV, 20V, 200V, 600V
Resolution: 0.1mV, 0.001V, 0.01V, 0.1V, 1V
Accuracy: 200mV to 20V ranges ± (1.2% of rdg + 4 dgts)
200V to 600V range ± (2.0% of rdg + 4 dgts)
Input impedance: 10MΩ
Overload protection: 600V DC or AC rms. 600V DC or AC rms for 15
seconds on 200mV range
DC CURRENT
Ranges: 200μA, 20mA, 200mA
Resolution: 0.1μA, 0.01mA, 0.1mA
Accuracy: ± (1.0% of rdg + 1 dgt)
Input protection: 0.25A/500V fast blow ceramic fuse
Specification
MM64