OPERATOR'S INSTRUCTION MANUAL
01 02
AC / DC CURRENT TRANSDUCER
1. Safety Information
The AC/DC current transducer has been designed
according to IEC-1010 and IEC1010-2-032 concerning
safety requirements for electrical measuring instruments
and hand-held current clamps with an over voltage
category (CAT II) and pollution 2.
Follow all introductions and operating requirements to
insure that AC/DC current transducer is used safely and
is kept in good operating condition.
1.1 Symbols
Important safety information,
refer to the operating manual.
Double insulation ( Protection
classII)
2. Description
Refer to the Figure 1. And to the following numbered steps
to familiarize yourself with the AC/DC current transducer
Transformer Jaws
Designed to pick up the ac. or dc current
following though the conductor.
Hand Guard
Designed to protect user for safety.
Trigger
Press the lever to open the transformer jaws.
DCA ZERO
Adjusting the DCA ZERO knob, when the
display is not zero reading for doesn't
measurement before.
Power On indication
Function Switch
Select the ac or dc current.
Output Plugs
1
2
3
4
5
6
7
03
AC / DC CURRENT TRANSDUCER AC / DC CURRENT TRANSDUCER AC / DC CURRENT TRANSDUCER
HYS006602
0706
Using this appliance in an environment
with a strong radiated radio-frequency
electromagnetic field (approximately
3V/m) may influence its measuring
accuracy. The measuring result can be
strongly deviating from the actual value.
5. DC Current Measurement
5.1
5.2
5.3
Set the AC/DC current transducer function
switch at desired A position.
Set a DMM at DCV function and a
relevant range.
Connect the output plug of AC/DC current
transducer with a DMM and combined
firmly.
5.5
5.6
Adjusting the DCA ZERO knob until the
DMM display show “0”, when does not
measurement before.
Press the trigger to open transformer jaws
and clamp one conductor only, making sure
that the jaws are firmly closed around the
conductor.
Read the reading on the LCD display of
DMM along with the polarity of the red
lead connection.
5.4
6. AC Current Measurement
6.1
6.2
6.3
Set the AC/DC current transducer function
switch at desired A~ position.
Set a DMM at DCV function and a relevant
range.
Connect the output plug of AC/DC current
transducer with a DMM and combined
firmly.
Press the trigger to open transformer jaws
and clamp one conductor only, making
sure that the jaws are firmly closed around
the conductor.
6.4
6.5
Read the reading from the digital display
of the DMM.
7. Maintenance
To keep the instrument clean, wipe the case with a damp
cloth and detergent, do not use abrasives or solvents.
Any adjustment, maintenance and repair shall be
conducted by service personnel.
Accessories
• Operator's instruction manual
• Gift box
• 9 volt battery. NEDA 1604 6F22 006P type
0504
3. Specifications
Accuracy is specified for a period of one year after
calibration and at 18°C to 28°C(64F to 82F) with relative
humidity to 80.
Accuracy specifications are given as:
±of reading digits
This instrument must not be used on
uninsulated conductors at a voltage
greater than 250V ac rms. or 250V dc
3.1 General
DC CURRENT RANGE: 1A dc to 1000A dc.
AC CURRENT RANGE: 1A ac to 1000A ac. RMS
OUTPUT VOLTAGE: 1mV dc. per 1 A dc or 1A ac.
WORKING VOLTAGE:
1000V CAT.II Per IEC 1010 - 1
MAXIMUM ALTITUDE: 2000m
OPERATING TEMPERATURE:
0°C to 40°<C 80 relative humidity
STORAGE TEMPERATURE:-10°C to 50°C
TEMPERATURE COEFFICIENT:
0.2×(Spec Acc'y) /°C <18°C or>28°C
MAXIMUM JAW OPENING: 55mm
SIZE: 256×104×47
WEIGHT: Approx. 520g
3.2 Electrical specification dc current
Range Measure Output Accuracy
1000mV1000A ± ±3.0% 5
A
Overload Protection:
1200A for 60 seconds maximum.
DC Current
AC Current
Range Measure Output Accuracy
1000mV1000A ± ±3.0% 5
A
Overload Protection:
1200A for 60 seconds maximum.
Frequency range: 50Hz to 60Hz.
4. Precaution and
Preparations for Measurement
4.1
4.2
4.3
Dot not applies the voltage to the output
plugs of AC/DC current transducer.
Do not use or store this instrument in a high
temperature or high humidity environment
and do not store the unit indirect sunlight.
Do not measure current before the AC/DC
current transducer is not combined with
DMM.
AC / DC CURRENT TRANSDUCER AC / DC CURRENT TRANSDUCER AC / DC CURRENT TRANSDUCER AC / DC CURRENT TRANSDUCER

This manual suits for next models

1

Other Mastech Measuring Instrument manuals

Mastech MS6700 User manual

Mastech

Mastech MS6700 User manual

Mastech MS20006 User manual

Mastech

Mastech MS20006 User manual

Mastech ms6231 User manual

Mastech

Mastech ms6231 User manual

Mastech MS6450 User manual

Mastech

Mastech MS6450 User manual

Mastech MS2002 Assembly instructions

Mastech

Mastech MS2002 Assembly instructions

Mastech MS2030A User manual

Mastech

Mastech MS2030A User manual

Mastech MS6503 User manual

Mastech

Mastech MS6503 User manual

Mastech MS2009C User manual

Mastech

Mastech MS2009C User manual

Mastech MS2109A User manual

Mastech

Mastech MS2109A User manual

Mastech MS2201 User manual

Mastech

Mastech MS2201 User manual

Mastech MS8240D User manual

Mastech

Mastech MS8240D User manual

Mastech MS2225A User manual

Mastech

Mastech MS2225A User manual

Mastech MS6252B User manual

Mastech

Mastech MS6252B User manual

Mastech MS2108 User manual

Mastech

Mastech MS2108 User manual

Mastech MS5308 User manual

Mastech

Mastech MS5308 User manual

Mastech MS5900 User manual

Mastech

Mastech MS5900 User manual

Mastech M266F Assembly instructions

Mastech

Mastech M266F Assembly instructions

Mastech MS2000R Assembly instructions

Mastech

Mastech MS2000R Assembly instructions

Mastech MS6503 User manual

Mastech

Mastech MS6503 User manual

Mastech MS2301 User manual

Mastech

Mastech MS2301 User manual

Mastech MS5901 User manual

Mastech

Mastech MS5901 User manual

Mastech MS2115B User manual

Mastech

Mastech MS2115B User manual

Mastech MS6508 User manual

Mastech

Mastech MS6508 User manual

Mastech MS2016A User manual

Mastech

Mastech MS2016A User manual

Popular Measuring Instrument manuals by other brands

PCB Piezotronics IMI SENSORS ICP HT628F01 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS ICP HT628F01 Installation and operating manual

Veto 160m user manual

Veto

Veto 160m user manual

Vega VEGAPULS 64 Quick setup guide

Vega

Vega VEGAPULS 64 Quick setup guide

Bosch GLM 30 Professional Original instructions

Bosch

Bosch GLM 30 Professional Original instructions

OXTS xOEM500 Hardware Integration Manual

OXTS

OXTS xOEM500 Hardware Integration Manual

Enel X JuiceMeter installation manual

Enel X

Enel X JuiceMeter installation manual

Siko AP05 Translation of the original installation instructions

Siko

Siko AP05 Translation of the original installation instructions

Exotek Instruments MC-380XCA user manual

Exotek Instruments

Exotek Instruments MC-380XCA user manual

wtw LR 325/001 operating manual

wtw

wtw LR 325/001 operating manual

Hanna Instruments HI5221 instruction manual

Hanna Instruments

Hanna Instruments HI5221 instruction manual

TFT 730A manual

TFT

TFT 730A manual

Atek HP 8753D user guide

Atek

Atek HP 8753D user guide

Cole Parmer 1100 Series user manual

Cole Parmer

Cole Parmer 1100 Series user manual

SCS 770066 Installation, operation and maintenance

SCS

SCS 770066 Installation, operation and maintenance

TR-Electronic LE-25 user manual

TR-Electronic

TR-Electronic LE-25 user manual

Hirschmann PAT DS 85/0002 Calibration manual

Hirschmann

Hirschmann PAT DS 85/0002 Calibration manual

Transforming Technologies GTS600 instruction manual

Transforming Technologies

Transforming Technologies GTS600 instruction manual

ENCARDIO RITE EAN-95MW user manual

ENCARDIO RITE

ENCARDIO RITE EAN-95MW user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.