OPERATOR'S INSTRUCTION MANUAL
01 02
AC / DC CURRENT TRANSDUCER
1. Safety Information
The AC/DC current transducer has been designed
according to IEC-1010 and IEC1010-2-032 concerning
safety requirements for electrical measuring instruments
and hand-held current clamps with an over voltage
category (CAT II) and pollution 2.
Follow all introductions and operating requirements to
insure that AC/DC current transducer is used safely and
is kept in good operating condition.
1.1 Symbols
Important safety information,
refer to the operating manual.
Double insulation ( Protection
classII)
2. Description
Refer to the Figure 1. And to the following numbered steps
to familiarize yourself with the AC/DC current transducer
Transformer Jaws
Designed to pick up the ac. or dc current
following though the conductor.
Hand Guard
Designed to protect user for safety.
Trigger
Press the lever to open the transformer jaws.
DCA ZERO
Adjusting the DCA ZERO knob, when the
display is not zero reading for doesn't
measurement before.
Power On indication
Function Switch
Select the ac or dc current.
Output Plugs
1
2
3
4
5
6
7
03
AC / DC CURRENT TRANSDUCER AC / DC CURRENT TRANSDUCER AC / DC CURRENT TRANSDUCER
HYS006602
0706
Using this appliance in an environment
with a strong radiated radio-frequency
electromagnetic field (approximately
3V/m) may influence its measuring
accuracy. The measuring result can be
strongly deviating from the actual value.
5. DC Current Measurement
5.1
5.2
5.3
Set the AC/DC current transducer function
switch at desired A position.
Set a DMM at DCV function and a
relevant range.
Connect the output plug of AC/DC current
transducer with a DMM and combined
firmly.
5.5
5.6
Adjusting the DCA ZERO knob until the
DMM display show “0”, when does not
measurement before.
Press the trigger to open transformer jaws
and clamp one conductor only, making sure
that the jaws are firmly closed around the
conductor.
Read the reading on the LCD display of
DMM along with the polarity of the red
lead connection.
5.4
6. AC Current Measurement
6.1
6.2
6.3
Set the AC/DC current transducer function
switch at desired A~ position.
Set a DMM at DCV function and a relevant
range.
Connect the output plug of AC/DC current
transducer with a DMM and combined
firmly.
Press the trigger to open transformer jaws
and clamp one conductor only, making
sure that the jaws are firmly closed around
the conductor.
6.4
6.5
Read the reading from the digital display
of the DMM.
7. Maintenance
To keep the instrument clean, wipe the case with a damp
cloth and detergent, do not use abrasives or solvents.
Any adjustment, maintenance and repair shall be
conducted by service personnel.
Accessories
• Operator's instruction manual
• Gift box
• 9 volt battery. NEDA 1604 6F22 006P type
0504
3. Specifications
Accuracy is specified for a period of one year after
calibration and at 18°C to 28°C(64F to 82F) with relative
humidity to 80.
Accuracy specifications are given as:
±of reading digits
This instrument must not be used on
uninsulated conductors at a voltage
greater than 250V ac rms. or 250V dc
3.1 General
DC CURRENT RANGE: 1A dc to 1000A dc.
AC CURRENT RANGE: 1A ac to 1000A ac. RMS
OUTPUT VOLTAGE: 1mV dc. per 1 A dc or 1A ac.
WORKING VOLTAGE:
1000V CAT.II Per IEC 1010 - 1
MAXIMUM ALTITUDE: 2000m
OPERATING TEMPERATURE:
0°C to 40°<C 80 relative humidity
STORAGE TEMPERATURE:-10°C to 50°C
TEMPERATURE COEFFICIENT:
0.2×(Spec Acc'y) /°C <18°C or>28°C
MAXIMUM JAW OPENING: 55mm
SIZE: 256×104×47
WEIGHT: Approx. 520g
3.2 Electrical specification dc current
Range Measure Output Accuracy
1000mV1000A ± ±3.0% 5
A
Overload Protection:
1200A for 60 seconds maximum.
DC Current
AC Current
Range Measure Output Accuracy
1000mV1000A ± ±3.0% 5
A
Overload Protection:
1200A for 60 seconds maximum.
Frequency range: 50Hz to 60Hz.
4. Precaution and
Preparations for Measurement
4.1
4.2
4.3
Dot not applies the voltage to the output
plugs of AC/DC current transducer.
Do not use or store this instrument in a high
temperature or high humidity environment
and do not store the unit indirect sunlight.
Do not measure current before the AC/DC
current transducer is not combined with
DMM.
AC / DC CURRENT TRANSDUCER AC / DC CURRENT TRANSDUCER AC / DC CURRENT TRANSDUCER AC / DC CURRENT TRANSDUCER

This manual suits for next models

1

Other Mastech Measuring Instrument manuals

Mastech MS20006 User manual

Mastech

Mastech MS20006 User manual

Mastech MS2600 User manual

Mastech

Mastech MS2600 User manual

Mastech MS2030 User manual

Mastech

Mastech MS2030 User manual

Mastech MS6701 User manual

Mastech

Mastech MS6701 User manual

Mastech MS6503 User manual

Mastech

Mastech MS6503 User manual

Mastech AZ8903 User manual

Mastech

Mastech AZ8903 User manual

Mastech MS2108 User manual

Mastech

Mastech MS2108 User manual

Mastech MS2138/R User manual

Mastech

Mastech MS2138/R User manual

Mastech MS6252A User manual

Mastech

Mastech MS6252A User manual

Mastech MS8238G User manual

Mastech

Mastech MS8238G User manual

Mastech MS2010A User manual

Mastech

Mastech MS2010A User manual

Mastech MS2108 User manual

Mastech

Mastech MS2108 User manual

Mastech MS6503 User manual

Mastech

Mastech MS6503 User manual

Mastech MS6900 User manual

Mastech

Mastech MS6900 User manual

Mastech MS6450 User manual

Mastech

Mastech MS6450 User manual

Mastech MS2225A User manual

Mastech

Mastech MS2225A User manual

Mastech MS5308 User manual

Mastech

Mastech MS5308 User manual

Mastech MS8239D User manual

Mastech

Mastech MS8239D User manual

Mastech MS2015B User manual

Mastech

Mastech MS2015B User manual

Mastech MS6700 User manual

Mastech

Mastech MS6700 User manual

Mastech MS2016A User manual

Mastech

Mastech MS2016A User manual

Mastech MS8240D User manual

Mastech

Mastech MS8240D User manual

Mastech ms6231 User manual

Mastech

Mastech ms6231 User manual

Mastech MS2109A User manual

Mastech

Mastech MS2109A User manual

Popular Measuring Instrument manuals by other brands

Hanna Instruments HI 8043 instruction manual

Hanna Instruments

Hanna Instruments HI 8043 instruction manual

Quandify CubicMeter LTCM02-X manual

Quandify

Quandify CubicMeter LTCM02-X manual

ABB C1900 Series installation guide

ABB

ABB C1900 Series installation guide

PCB Piezotronics 3501A2020KG Installation and operating manual

PCB Piezotronics

PCB Piezotronics 3501A2020KG Installation and operating manual

PCE Health and Fitness PCE-T 1200 manual

PCE Health and Fitness

PCE Health and Fitness PCE-T 1200 manual

SWI L505 Installation and operation manual

SWI

SWI L505 Installation and operation manual

MarMonix MAN-745 user manual

MarMonix

MarMonix MAN-745 user manual

Hesai Pandar20A user manual

Hesai

Hesai Pandar20A user manual

Hanna Instruments HI 847492 instruction manual

Hanna Instruments

Hanna Instruments HI 847492 instruction manual

Deif TRI-2 user manual

Deif

Deif TRI-2 user manual

Keysight M9383B VXG-m Measurement guide

Keysight

Keysight M9383B VXG-m Measurement guide

Parkside PKLL 7 A1 operating instructions

Parkside

Parkside PKLL 7 A1 operating instructions

Dirotec Nivcomp RX1 Attachment to the manual

Dirotec

Dirotec Nivcomp RX1 Attachment to the manual

Kobold TIN-SS operating instructions

Kobold

Kobold TIN-SS operating instructions

4iiii PM100 quick start guide

4iiii

4iiii PM100 quick start guide

LOVATO ELECTRIC DME D112 installation manual

LOVATO ELECTRIC

LOVATO ELECTRIC DME D112 installation manual

Branchpoint Technologies AURA TK101-A Instructions for use

Branchpoint Technologies

Branchpoint Technologies AURA TK101-A Instructions for use

Goobay 77001 user manual

Goobay

Goobay 77001 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.