DANGER: Remove power from the pump before any cleaning operation is started.
WARNINGS: Remove power from the pump before attempting any maintenance.
The Power switch on the Back Panel is not the main disconnect. A contactor or
other device that routinely disconnects and reapplies the AC line to the drive to start
and stop the motor can cause drive hardware damage. The drive is designed to use
control input signals that will start and stop the motor.
WARNINGS: Tubing breakage may result in fluid being sprayed from pump. Use
appropriate measures to protect operator and equipment.
Turn Pump System off before removing or installing tubing. Fingers or loose clothing
could be caught in drive mechanism.
CAUTIONS: Replace the fuse only with one of the same type and rating. The fuse
rating and type are stated on the rear panel.
Power must be turned off before connecting the external remote control cable to
prevent damage to the drive.
CAUTIONS: To avoid electrical shock, the power cord protective grounding conductor
must be connected to ground. Not for operation in wet locations as defined by
EN61010-1.
If the product is not used in a manner specified in the instructions, the protection
provided by the equipment may be impaired.
CAUTION: Risk of Danger. Consult Operator’s manual for nature of hazard and
corrective actions.
CAUTION: Risk of crushing. Keep fingers away from rotor while pump is in operation.
Stop pump before loading or unloading tubing.
CAUTION: Risk of electric shock. Consult Operator’s manual for nature of hazard and
corrective actions.
This product is not designed for, nor intended for use in patient connected
applications; including, but not limited to, medical and dental use, and accordingly
has not been submitted for FDA approval.
This product is not designed for, nor intended for use in hazardous duty areas as
defined by ATEX or the NEC (National Electrical Code); including, but not limited to
use with flammable liquids. Consult the factory for products suitable for these types
of applications.
SAFETY
PRECAUTIONS
!
!
Explanation of
Symbols
!
!
WARNING:
Product Use
Limitation
C
12
year
warranty
70 dba @ 1M
-25C, -13F +65C, +149F
+0C, +32F +40C, +104F
EN61010-1 L.V. DIR.
EN61326-1 EMC DIR.
EN60529 / IEC 60034-5
07522-20, -30
07551-20, -30
13 lbs. (5.9 kg)
IP 07522-20, -30
07551-20, -30
07522-20, 07551-20 0.1-600 rpm
07522-30, 07551-30 0.02-100 rpm
I
33
TUBING CAL
CAL DE TUBER˝A
TALON. TUYAU
ROHRLEITUNGSKAL
TARATURA TUBI
FLOW RATE
CAUDAL
DB IT
DURCHFLUSSRATE
INDICE DI FLUSSO
ANTI-DRIP
SIN GOTEO
ANTI-GOUTTES
KEIN TROEN
ANTISGOCCIOLO
10
Pin No.
DB-25 Description
Speed Control Voltage Input (0-10 V)
Speed Control Current Input (0-20 mA)
Speed Control Input Ground Return
Speed Signal Current Output (0-20 mA)
Speed Signal Output Ground Reference
(Motor Running N.O. Default) 1A @24V (Open Collector)
Motor Running Ground Return
(Motor Running N.C. Default) 1A @24V (Open Collector)
Speed Signal Voltage Output (0-10 V)
Remote Start/Stop Input
Remote CW/CCW Input
Remote Start/Stop, CW/CCW, Prime Grnd Ref.
Tach Ground Reference
Tach Output (Open Collector)
Remote Prime Input
General Alarm Output
Local/Remote Indicator
Reserved - Not Used
Reserved - Not Used
Aux 24V+
Aux 24V-
1
2
3
4
5
6
7
8
14
15
16
17
18
19
20
23
24
9-12
21-22
25
13
13 12 11 10 9 8 7 6 5 4 3 2 1