INSTALLATION
US / WHISPER 30 ULTRA / November 2008 / Copyright © 2008 Mastervolt 15
Automatic start/stop
Mastervolt cannot be held responsible for
damage caused by the unattended running
generator using the auto-start/stop mode or
interval mode
Using the auto-start/stop (interval) mode the
generator can start unexpectedly. When
working on the electrical system, the 3 Amp
fuse must be removed from the control panel
and the battery plus cable must be removed
from the battery.
In the delivery are warning stickers to stick on
several parts of the electric installation
(transfer switch, distribution box, etc.) to warn
for automatic start)
The Mastervolt Digital Diesel Control system offers several
options for automatic starting and stopping.
Access to this menu and other menus could be blocked.
For blocking and setting up this options refer to the
APPENDIX of the DDC users manual.
One of these options is to monitor a second battery (not
being the starter battery) to start the generator
automatically when the voltage of this battery drops below
a certain setting.
Other names for this second battery are “auxiliary battery”,
“service battery”, ”users battery” or “consumers battery”.
We will refer to this battery as “the second battery”(BAT2).
In some menus the starter battery could be indicated as
“the first battery” (BAT1).
A sense wire to monitor the second battery should be
connected (attention polarity!) to the connector on the
back of the remote panel. Refer to fig. 17. The sense wires
must be connected directly on the second battery before a
main switch and be protected by a 3 Amps fuse.
(Monitoring the generator starter battery does not require
an extra sense connection)
Settings
When one want to apply other settings than the factory
settings refer to the DDC users manual, especially to the
APPENDIX.
2 STARTER BATTERY
For starting, the Whisper requires a battery with a capacity
of at least 120 Ah. The generating set can be connected
with the main engine battery or have its own battery.
We strongly recommend the use of a separate battery for
the generating set and to keep the wiring system for the
propulsion engine and the domestic DC supply system
completely separate and individually connected to
separate batteries.
230VAC
IVO12/10
AB
12V
+-
Figure 18 Starter battery
However, the negative of all the batteries on the vessel
should be interconnected (when on earth) to avoid
difference in the voltage level of the earth on different
places causing trouble to electronic devices which might
be in the system.
The above recommendation is not valid for ships having
the starter battery of the propulsion engine or other
auxiliary equipment positive grounded. When this is the
case an expert should be consulted.
A battery switch may be used to interrupt the positive
connection.
The starter battery is charged by the alternator on the
engine. An additional battery charger will help to keep the
battery in good condition when the generating set is not
used. A battery charger is not included in the standard
supply. A high efficiency battery charging unit can be
ordered from Mastervolt which is able to charge both the
ship’s main battery and the starter battery. Also a small
charger can be used to charge the starter battery only,
such as the IVO SMART 12/10. A battery switch and a
charger are included in the battery installation kit, art. no.
50230220 (160Ah)