INSTALLATION
14 November 2006 / WHISPER 3,5 for mobile applications / EN
Never take off 12 Volt from one battery off a
24-Volt battery bank (12-Volt batteries that are
in series). This will cause serious damage to
the batteries in short time.
Disconnect the battery leads if electrical welding is to
be carried out, otherwise damage will be caused to
the diodes of the alternator.
As explosive hydrogen gases are discharged
during charging, the battery should be located
in a well ventilated room. Ensure that the
supplied battery cable connectors are properly
fitted and never remove during or shortly after
charging as sparking can occur, which may
ignite the hydrogen gasses.
2.4.5 AC power system (230 Volt)
The electric power supplied by the generator
is of a high voltage and dangerous to people.
Realise hat people are not used to have 230V
available on a vehicle. Put warning signs on
wall sockets and on junction boxes. Instruct
non-regular users of the vehicle. Warn
maintenance personal of garages that do
service on the vehicle.
Generators used on vehicles that are
operated in a hazardous environment have
often to fulfil special regulations and additional
measures have to be taken accordingly.
Be sure that all electrical installations (including all safety
systems) comply with all required regulations of the local
authorities. All electrical safety/shutdown and circuit
breaking systems have to be installed onboard as the
generating set itself cannot be equipped with such
equipment for every possible variation.
The vehicle’s power supply system (grid) should be
suitable and safe for the AC voltage which is applied and
the power that will be generated. Special attention has to
be paid on dividing the system in branches which are
fused individually. Wire colours should comply with AC
standards. It is absolutely essential that each and every
circuit in the on-board electrical system is properly
installed by a qualified electrician.
1 FUSE
An input fuse (from the generating set to the system)
should be installed to protect the installed electrical
system.
For the Whisper 3,5 the maximum single phase
current at 230V is 13A.
The fuses must be of the slow reacting type. For
electrical motors connected to the system, a motor
protection switch must be installed.
2 INSULATION FAILURES
The AC alternator windings are not grounded.
The housing of the alternator and all other metal parts
are grounded.
To make a connection between “neutral” and “ground”
could be necessary as part of a specific insulation
failure protection system.
It is possible that the electric installation in the vehicle
must be protected against insulation failures. Methods
of protection are subjected to rules that can be
different depending on the use of the vehicle and local
standards.
In the standard marine manual is more information,
but this is according CE regulations for boats.
Vehicles are subject to different regulations
depending on the application of the vehicle. Experts in
this field should be consulted
3 CABLE
For the power cable in single phase installations we
recommend the use of flexible 3 wire oil resistant
cable with a sufficient cross sectional area 3 x 2,5
mm2. One wire for earth is included. For very long
cables it is recommended to apply cables with a
larger cross section.
4 TRANSFER SWITCH
A power source selector switch must be installed
between the generating set and the car’s electrical
supply system. This switch must ensure that all AC
consumers can be switched off at once. This switch
should also be installed to keep the generating set
and shore (grid) power systems separate.
Transfer switches - to switch over from shore to ship
or from generating set to inverter - should be well
designed to switch over all wires including neutral
(and not only phases or line) and there should be
provisions with the aid of timers to prevent relays from
chattering.
Mastervolt advises the installation of a
MASTERSWITCH as the power source selector. This
works automatically when the generating set is not
running the input remains in the shore position and as
soon as the generating set is running the
MASTERSWITCH switches automatically after 10
seconds delay time over to the generating set
position.