manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Maverick
  6. •
  7. Thermometer
  8. •
  9. Maverick LT-02 User manual

Maverick LT-02 User manual

Other Maverick Thermometer manuals

Maverick OT-3 Owner's manual

Maverick

Maverick OT-3 Owner's manual

Maverick ET-64 User manual

Maverick

Maverick ET-64 User manual

Maverick Redi Chek ET-73 Owner's manual

Maverick

Maverick Redi Chek ET-73 Owner's manual

Maverick ET-8 User manual

Maverick

Maverick ET-8 User manual

Maverick BT-150 STAKE User manual

Maverick

Maverick BT-150 STAKE User manual

Maverick ET-77 User manual

Maverick

Maverick ET-77 User manual

Maverick PT-50 User manual

Maverick

Maverick PT-50 User manual

Maverick ET-706 User manual

Maverick

Maverick ET-706 User manual

Maverick ET-901B User manual

Maverick

Maverick ET-901B User manual

Maverick HD-8 User manual

Maverick

Maverick HD-8 User manual

Maverick RediFork Pro ET-63 User manual

Maverick

Maverick RediFork Pro ET-63 User manual

Maverick OvenChek ST-01 User manual

Maverick

Maverick OvenChek ST-01 User manual

Maverick RF-01 User manual

Maverick

Maverick RF-01 User manual

Maverick COLD-CHEK RF-02 User manual

Maverick

Maverick COLD-CHEK RF-02 User manual

Maverick DGT-310 User manual

Maverick

Maverick DGT-310 User manual

Maverick Remote Thermometer User manual

Maverick

Maverick Remote Thermometer User manual

Maverick Redi Chek IRT-02 User manual

Maverick

Maverick Redi Chek IRT-02 User manual

Maverick ET-737 ICHEF User manual

Maverick

Maverick ET-737 ICHEF User manual

Maverick ET-53 User manual

Maverick

Maverick ET-53 User manual

Maverick RediChek ET-7 User manual

Maverick

Maverick RediChek ET-7 User manual

Maverick OT-01 Owner's manual

Maverick

Maverick OT-01 Owner's manual

Maverick ET-71D User manual

Maverick

Maverick ET-71D User manual

Maverick ET-75 User manual

Maverick

Maverick ET-75 User manual

Maverick DT-09 User manual

Maverick

Maverick DT-09 User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Taylor 5286498 instruction manual

Taylor

Taylor 5286498 instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

L
LT
T-
-0
02
2
I
In
nf
fr
ra
ar
re
ed
d
L
La
as
se
er
r
B
BB
BQ
Q
S
Su
ur
rf
fa
ac
ce
e
T
Th
he
er
rm
mo
om
me
et
te
er
r
I
In
ns
st
tr
ru
uc
ct
ti
io
on
ns
s
The LT-02 is a non-contact infrared thermometer, with Real-Time Maximum (MAX) temperature display.
Please remember to keep away from children and don’t use it for safety related applications.
Features:
oC or oF Press Mode key (○
2) for oC or oF transferred.
Backlight LCD Backlight: always on.
Laser ClassII Laser: always enable while measuring.
EMC/RFI
Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
* Note: Under the electromagnetic field of 3V/m from 350 to 550MHZ, the maximum error is 8°C (14.4°F).
CAUTION
1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE
MAY RESULT.
2. USE EXTREME CAUTION WHEN OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.
4. KEEP OUT OF REACH OFALL CHILDREN.
STORAGE & CLEANING
The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times, care should
be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allowing the
lens to fully dry before using the thermometer. Do not submerge any part of the thermometer. The thermometer
should be stored at room temperature between –20 to +65°C (-4~149°F).
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
「」
「」
‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature.
‘Er3’ is displayed when the ambient temperature exceeds 0oC(32°F) or +50oC (122°F).
The thermometer should be allowed plenty of time (minimum 30 minutes) to stabilize to the
working/room temperature.
「」
For all other error messages it is necessary to reset the thermometer. To reset it, turn the
instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and
turn on. If the error message remains please contact the Service Department for further
assistance.
(Default Screen)
BATTERIES
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements
are possible ‘Battery Low’: battery needs to be
replaced, measurements are still possible ‘Battery Exhausted’: measurements
are not possible
When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AAA,
1.5V batteries. Please note: It is important to turn the instrument off before replacing the battery otherwise the
thermometer may malfunction. Dispose of used battery promptly and keep away from children.
SPECIFICATION
Measurement Range -50 to +550oC (-58 to +1022oF)
Operating Range 0~50°C (32~122°F)
Accuracy, (Tobj=15-35°C,Tamb=25°C) +/-1.0°C (1.8°F)
Accuracy (Tobj=-33-400°C,Tamb=23 +/- 3°C) +/-2% of reading or 2°C (4°F) whichever is greater
Emissivity 0.95 fixed
Resolution (-9.9~199.9°C) 0.1°C/0.1°F
Response Time (90%) 1sec
Distance:Spot 9:1
Battery Life Typ.18, min 14 hours continuous use
Dimensions 175.2 x 39.0 x 71.9mm
Weight 179 grams including batteries (AAA*2pcs)
** The thermometer will automatically shut off if left idle for more than 15sec.
MAVERICK LIMITED 90 DAY WARRANTY
Maverick Industries Inc. warrants this product to be free of defects in parts, materials and workmanship for a period of 90 days, from date of purchase.
Should any repairs or servicing under this warranty be required, contact Maverick Customer Service by mail or phone for instructions on how to pack
and ship the product to Maverick's National Service Center located as follows:
Maverick Customer Service
94 Mayfield Ave.
Edison NJ 08837
Telephone: (732) 417-9666
Hours: Weekdays 8:30AM- 4:30 PM
Do not send any parts or product to Maverick without calling and obtaining a Return Authorization Number and instructions.
This warranty is VOID if instructions for use are not followed; for accidental damage; for commercial use; for damage incurred while in transit; or if the
product has been tampered with.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
www.maverickhousewares.com
1. Simply aim the thermometer at the
target with Laser (⑤) and press
trigger (○
6) to display the surface
temperature.
2. During the measurement, the MAX
reading will be displayed beside the
icon.
3. The Distance:Spot is 9:1. Please make
sure the target area is within the field
of view.