Medirol Sanero M201 User manual

Monoblock
SANERO M201
User Manual

2
Content
Content .................................................................................................................................................... 2
Introduction ............................................................................................................................................. 3
Safet Information ................................................................................................................................... 4
ES Conformit Declaration ...................................................................................................................... 5
Guarantee Certificate .............................................................................................................................. 6
Product Description ................................................................................................................................. 7
Technical Parameters .............................................................................................................................. 8
Operating Instructions ........................................................................................................................... 10
Positioning of the footrest ................................................................................................................ 10
Positioning of the backrest ................................................................................................................ 11
Side folding grab handles .................................................................................................................. 12
Positioning of the rear legs ................................................................................................................ 13
Positioning of the front legs .............................................................................................................. 14
Unlocking of front wheels whirl ........................................................................................................ 15
Drive into ambulance car .................................................................................................................. 16
Drive into ambulance car .................................................................................................................. 17
Basic Accessories ................................................................................................................................... 18
Belt s stem and mattress with pillow ............................................................................................... 18
Maintenance ......................................................................................................................................... 19
Maintenance schedule ...................................................................................................................... 19
Revision ............................................................................................................................................. 19
Cleaning ............................................................................................................................................. 19
Disinfection ........................................................................................................................................ 19
Oiling.................................................................................................................................................. 19
Inspectional Note .................................................................................................................................. 20
Monoblock ......................................................................................................................................... 20
Mattress ............................................................................................................................................ 20
Belt s stem ........................................................................................................................................ 20
Training Note ......................................................................................................................................... 21
Note from inspection ............................................................................................................................ 22

3
Introduction
Thank ou for purchasing a monoblock SANERO M201. To take full advantage of all features of the
product, carefull read all instructions and put it onto available place in order to it is accessible for all
potential users.
Attention
This manual contains general instructions for use, operation and maintenance of this product.
Directions can not cover all the details, so safe and proper use of this product is entirel on user.
Safet information is provided as a service to users. All other securit measures taken b the user
should be under the applicable regulations. It is recommended arranging training about the correct
use of this product in specific situation before use.
No part of the manuals delivered with this product ma not be reproduced, copied, transmitted,
stored in a backup s stem or translated in an form into another language without prior written
permission of Medirol.
Although maximum effort has been made to achieve accurac and completeness of the information
contained in this manual, we will welcome, if ou tell about an discrepancies or missing information
to Medirol regional representative.

4
Safety Information
This icon indicates a warning. To avoid possible injur to operator or patient, read all
warnings before using this product.
Warning
The product may be operated only by trained personnel.
Untrained personnel ma cause injur .
Use the product only for purposes described in this manual.
Improper use of product ma cause injur .
Always stay with the patient.
Health of patient without supervision ma be in danger.
Always use the restraint system to secure patient.
Unsecure patient ma be injured.
Maintain the product as described in this manual.
Improper maintenance ma cause injur .
Use only original accessories and parts for service.
Improper parts and service ma cause injur .
o not tamper with the product design.
Modifications of product ma cause injur or product damage.
COMPATIBILITY WITH FASTENING SYSTEM
Integral part of the monoblock SANERO is fastening s stem ROLFIX, fixing the ambulance cot in
ambulance car. MEDIROL Compan Ltd. strongl recommended to fasten the monoblock onl using
fastening s stem Medirol® ROLFIX F102, which with the monoblock Medirol®SANERO M201 complies
with European standard EN 1789 in section 4.5.9. Using products from other manufactures greatl
increases the risk of personal injur or risk of harm to the patient or stretcher.

5
ES Conformity eclaration
According § 13 sec. 2 law no.22/1997 about technical requirements for products and according
government regulation no. 336/2004 b which is stated technical requirements at medical means.
Producer:
ME IROL s.r.o., Na Strži 126/4, 140 00 Praha 4, Czech Republic, VAT no.: CZ64506592
Manufacturing plant:
MEDIROL s.r.o., Dolní Dubňan 58, 671 73 Tulešice, Czech Republic
Product´s name and t pe:
SANERO M201
Description:
Medical device for transport of recumbent patient into and outside of ambulance car.
Registered in class:
Non-invasive I
Statement
Meet basic requirements, in common use in accordance with user manual is safe, effective, and
appropriate for providing health care. Producer accepted precautions b which ensure conformit of
all medical means with the technical documentation and the basic requirements of the Government,
which appl to it.
To proof the conformity was used following documentation:
•Technological regulation M201
•Government regulation no. 336/2004
•ČSN EN 1865, 1789
•Protocol no. 120247-10-TAC about test according regulation ČSN EN 1789 issued b TÜV SÜD
Czech s.r.o. 7.4.2010 in Prague
Prague 6. 9. 2011
Ing. Diana R sková
Managing Director and CEO

6
Guarantee Certificate
The producer MEDIROL Ltd. provides a guarantee for each product against defects in materials and
workmanship:
With two years guarantee-
•monoblock frame and all its components
•pillow
•mattress
•restraint s stem
•wheels
This warranty does not cover:
•standard wear
•improper installation
•improper maintenance
•installation of parts or accessories which are not originall intended for this product (or are
not compatible with it)
•damage or failure due to accident, improper use, misuse or negligence
In case of an modification of frame or an parts of the product this warrant expires completel .
Producer proceeds repair in guarantee time b product´s repair or exchange for another.
Producer does not cover the freight charge for defective product or its parts.
Production label and this confirmed guarantee certificate are documents for claiming the guarantee.
Product´s name and t pe: Monoblock SANERO Model: M201
Serial number: Date of sale:
Dealer:
Signature and stamp:

7
Product escription
The monoblock Medirol® SANERO M201 is equipment designed for transport of recumbent patient
on paved surface.
Standard Features
•
High-strength aluminum construction
•
Ergonomic design
•
Fixed patient section allowing cardiac massage
•
One-hand release, fold-down side rails
•
Infinite positioning, lift assist, pneumatic backrest and legrest
•
Seven height positions
•
Oversized wheels absorbing shaking from unevenness
•
Remote steer lock s stem
•
Roll-in loading with two-step load release mechanism
•
One four-point shoulder harness restraint
•
One belt restraints
•
Anatomic mattress
•
Anatomic pillow
Technical Specification
Length 195 cm
Width 56 cm
Height 32, 66, 74, 81, 88, 95, 102 cm
Weight (without mattress and restraints) 43 kg
Wheels Diameter: 20cm, Width: 5 cm
Articulation
Backrest 0° - 85°
Legrest 0° - 30°
Maximum load capacit 275 kg
Recommended loading height 70 cm
Recommended fastener s stem F102 ROLFIX
Specifications are rounded to the nearest whole number.

8
Technical Parameters

9

10
Operating Instructions
Positioning of the footrest

11
Positioning of the backrest

12
Side folding grab handles

13
Positioning of the rear legs
It is not allowed to brake the trolle during positioning – rear swivel wheels have to find
their position themselves.
During positioning the monoblock alwa s uplift to
decrease the action of force at the positioning locker.
Handle of monoblock´s carriage during legs positioning,
entr and exit from ambulance car alwa s hold from
under, as presented at the picture to avoid tripping
of the carriage from hands.
During monoblock riding in an case do not manipulate with lever for back legs release.
With forward riding might happen unwanted folding of front legs.

14
Positioning of the front legs
It is not allowed to brake the trolle during positioning – rear swivel wheels have to find
their position themselves.
During positioning the monoblock alwa s uplift to decrease the action of force at the
positioning locker.

15
Unlocking of front wheels whirl
Set the brake of monoblock´s carriage

16
rive into ambulance car
During drive into ambulance car is possible to take advantege to sequent unlock of the locker front
and rear legs in two positions of the operating lever.
During drive into ambulance car
monoblock must be alwa s in basic
transport position.

17
rive into ambulance car
During drive into ambulance car and unlocking the locker for positioning monoblock alwa s
uplift in order to reduce action of force at locker for positioning.
During drive out from ambulance car is necessar hold lever of the lock off legs locker
during unfold rear legs. Especiall care about right unfold of front legs which must be safel
secured in unfolded position before front carriage wheels ride down from ambulance car´s
deck.

18
Basic Accessories
Belt system and mattress with pillow
Mattress with pillow
A – 1806 Anatomical mattress
B – 1803 Anatomical pillow
Belt system
C – 1707 Four-point belt
D – 1712 Cross belt E

19
Maintenance
Maintenance schedule
The stretcher requires regular maintenance. Build our maintenance schedule and follow it. The
table below represents the minimum maintenance intervals.
Activity Plan
Cleaning and disinfection After ever use
Inspection (see checklist)
•
B use frequenc 1-25x a month
maintain inspection ever 6 months
•B use frequenc 26-200x a month
maintain inspection ever 3 months
•B use frequenc over 200x times a
month maintain inspection ever month
Revision
MEDIROL recommend doing revision regularl . First revision inspection performs after 2 ears and
then regularl ones a ear.
Cleaning
•wash all parts with warm water
•remove blood stains with brush or solvent
•blow the water with compressed air and wipe with soft cloth
•surface treat with universal agent WD-40 and polish
isinfection
•common disinfectants based on active and h drogen peroxide can be used to disinfect
•the producer recommends to perform test on hidden unused place if used disinfectant is
inert to the surface of the surface of the product cover
Warning
Long-term use of disinfectants in excessive concentration without neutralization may change color of
surface, or damage the surface. For cleaning and disinfection of surface do not use the products
containing organic solvents such as acetone, toluene and gasoline.
Oiling
Lubricate all hinged and sliding joints with the universal product WD-40. Disinfectant ma cause
undesirable degreasing of moving joints. Therefore pa attention to correct lubrication.

20
Inspectional Note
Serial number: Name:
T pe number: Date:
Monoblock
All mechanical and screw joints are solid
All welded joints are unbroken, without craks
No part of framework is not dismounted
Overrunning wheels easil rotating, in wheel axis are not an impurities
Main riding wheels are tightl attached, freel rotating and without impurities in wheel axis
Wheel brake s stem is full functional
Monoblock can properl drive into ambulance car and drive out from ambulance car
Mechanism for safet monoblock height positioning is full functional in all positions
Mechanism for safet folding and unfolding legs b drive into and out from ambulance car is
full functional
Control bar of height trolle safet is unbroken
Sides folding grab handles are full functional
Backrest and footrest can be fixed in arbitrar position and is full functional
Monoblock can be easil locked into fastener in ambulance car
Optional accessories is undisturbed and full functional
Mattress
An breaks on surface b graze, tear, rip up
Belt system
Full functional locking buckles and reduction of length buckles
An breaks on belt surface b graze, tear, rip up
An breaks of sawn belt joints
Do not use the product once the fault is detected and contact authorized service partner or
producer.
Table of contents
Other Medirol Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Dräger