MedViron 523-0150-0000 Manual

530‐MOMM‐0000Rev4
Operations & Maintenance Manual
Guardian Bassinets

Guardian Bassinets
2
Symbols used in this manual:
Warning symbol. The warning symbol is used to identify critical hazards.
Important Note symbol. This symbol is used to identify important information that
should be remembered.
Contact Information
Medviron LLC Toll free: 1-844-633-8476
9380 Pentatech Drive
Zeeland, Michigan 49464 USA Website: medviron.com
Mailing address:
Medviron LLC
P.O. Box 286
Zeeland, Michigan 49464 USA

Guardian Bassinets
3
Table of Contents:
Symbols used in this manual ________________________________________________________________________2
Manufacturer Contact Information__________________________________________________________________ 2
Guardian Bassinet Description ______________________________________________________________________ 4
Purpose _____________________________________________________________________________________________ 4
Features ____________________________________________________________________________________________ 5
Specifications________________________________________________________________________________________ 5
Contraindications____________________________________________________________________________________ 6
Operating Instructions:
Moving the Guardian Bassinet ______________________________________________________________ 6
Trendelenberg positioning _________________________________________________________________ 7
Serial Number Location_____________________________________________________________________________ 8
Safety and Risks ____________________________________________________________________________________ 9
Cleaning Instructions_______________________________________________________________________________ 10
Preventative Maintenance List _____________________________________________________________________ 11
Service Parts_______________________________ ________________________________________________________ 12
Warranty ___________________________________________________________________________________________13

Guardian Bassinets
4
Description
The Guardian Bassinet has two distinct parts, a plastic tub with mattress which sits on top of a
mobile wood storage cabinet with drawers. The Guardian Bassinet offers a warm design and
finishes so as to convey the warmth of home and also to imply competent, current, modern
healthcare.
The Guardian Bassinet can be made with or without plastic chart holders, and also with or without
pull-out documentation trays.
Purpose
The functional design of the Guardian Bassinet accommodates the care and transport of an infant
patient, the capability of Trendelenberg positioning of the Guardian Bassinet infant tub, and the
storage of care items for the infant.
The Guardian Bassinet is intended to be sold to and for use by professionally licensed staff and
facilities caring for the labor and delivery of children.
The Guardian Bassinet has been designed and manufactured under and to all pertaining ISO 13485
standards.
The Guardian Bassinet is intended for indoor use only.
The improper use of the Guardian Bassinet can lead to injury to the infant or to
the healthcare professional operating the Guardian Bassinet. Use the Guardian
Bassinet only as intended, as defined in this manual.
Changes made to the Guardian Bassinet or its parts can lead to injury to the
infant or healthcare professional who is operating the Guardian Bassinet.
Making any changes to the Guardian Bassinet also voids its warranty.

Guardian Bassinets
5
Features:
Two design goals for the Guardian Bassinet were lower cost of ownership for the hospital and
improving the experience of mother, caregiver, and family.
1. The Guardian Bassinet’s stainless steel push handles and all surface areas are easily accessible
and easy to clean. The tub and handle design allow a clear view of the infant.
2. KYDEX®thermofilm has been used on all horizontal surfaces for impact resistance and
durability.
3. The Guardian Bassinet’s molded ABS drawer boxes are removable for ease of cleaning.
4. The base panel has been designed to reduce the chances of caregivers hitting their shins while
the Guardian Bassinet is in motion or while caring for the infant. Also, the surface of the base
panel is limited so that the newborn’s older siblings cannot use it as a step to get to the
newborn.
5. We offer integrated pulls so siblings cannot use handles as climbing aid.
6. Optional side-mounted chart holder available upon request.
7. Optional pull-out documentation tray is available upon request. The tray has a containment
groove to keep items from rolling off.
Specifications:
Handle height: 36in (92.5cm)
Surface height: 30in (76.25cm)
Length: 34in (86.4cm)
Width: 20.85in (53cm)
Weight: 112lbs (51kg)

Guardian Bassinets
6
Contraindications:
1. The Guardian Bassinet infant tub is not intended to be used without the base cabinet.
2. The Guardian Bassinet’s plastic drawer liner is not intended to be used for anything other than
as a drawer.
3. The Guardian Bassinet is not intended to be used for infants that can sit, stand or roll over.
4. The Guardian Bassinet tub or drawer boxes are not intended to be used for bathing.
Operation: Moving the Guardian Bassinet
1. Stand at either the left or right side of the Guardian Bassinet.
2. Make certain the Guardian Bassinet tub is secure and that drawers or doors are closed.
3. Place both hands on the Guardian Bassinet push handle and push forward gently.
4. Make certain that the Guardian Bassinet is always in front of you. Do not pull the Guardian
Bassinet behind you.
Never push the Guardian Bassinet from the front or rear.
Never pull the Guardian Bassinet behind you.
GuardianBassinet
rear
front
rightside
leftside
Push only in this direction

Guardian Bassinets
7
Operation: Trendelenberg Positioning
To put the Guardian Bassinet tub into the Trendelenberg or Reverse Trendelenberg position, simply
raise either end of the tub and then lower it so that the hook on the side of the tub engages the
metal rail that bisects the push handle.
Do not let go of the tub until you are certain the tub hook is firmly seated on
the rail.
Never place any foreign objects inside or on top of the Guardian Bassinet tub.
Lift this side
and engage the
hook
for the
Trendelenberg
Position.
Lift this side and
engage the
hook
for the Reverse
Trendelenberg
Position.

Guardian Bassinets
8
Serial Number Location
The serial number is located on the exterior of the drawer box on the right side.
Contact Information
Medviron LLC Toll free: 1-844-633-8476
9380 Pentatech Drive
Zeeland, Michigan 49464 USA Website: medviron.com
Mailing address:
Medviron LLC
P.O. Box 286
Zeeland, Michigan 49464 USA

Guardian Bassinets
9
Safety and Risks:
When putting the Guardian Bassinet tub into the Trendelenburg or Reverse-
trendelenberg position, always verify that the tub hook is secure and seated
firmly on the rail.
Objects should not be left in or on top of the Guardian Bassinet infant tub at any
time.
The maximum weight load of each of the Guardian Bassinet drawers is 25 pounds
(11.3Kg). This is necessary to avoid tipping the Guardian Bassinet when drawers
are open.
The maximum weight load of the pull-out charting / documentation tray is 10lbs
(4.5Kg). This is necessary to avoid tipping the Guardian Bassinet.
When moving the Guardian Bassinet, the operator should push only from the
either end using the Guardian Bassinet handles.
To avoid tipping hazards of this device, make certain that the bed component
fits firmly in the base, and that all doors, drawers and casters are secure.

Guardian Bassinets
10
Product Care and Disinfection
Clean with a damp cloth or mild detergent solution. MedViron
furniture can withstand a wide
range of hospital cleaners and disinfectants. When using any of these products, read and follow
the manufactures directions carefully. Do not use abrasive or solvent cleaner. A CDC
recommended chlorinated bleach solution of 5.25% -6.15% sodium hypochlorite (i.e., household
bleach) diluted in water at 1:100 also can be used.
Infant tub: Always use a soft cloth or sponge on the Guardian Bassinet’s infant tub for washing
and rinsing. Liquid dish detergent is an acceptable cleaner. Never use abrasives or solvent
cleaners. Always follow up the application of any cleaning solution with a warm water rinse.
Clean the tub and mattress after each patient. Do not immerse the mattress in cleaning solution.
Make certain the mattress and tub are completely dry after each cleaning.
After cleaning, it is important that the Guardian Bassinet is rinsed with warm
water using a clean damp cloth and then wiped with a clean dry cloth to remove
any moisture.

Guardian Bassinets
11
Preventative Maintenance List:
_____ Casters: Casters should turn smoothly and should be free of any debris. Caster brakes
should hold firmly, the wheel should not turn when brake is applied.
_____ Plastic drawer liners: Should be clean and free of damage.
_____ Drawer slides: Drawers should open smoothly and quietly.
_____ Documentation / chart board: The chart board should pull-out and push back in easily.
_____ Guardian Bassinet tub: Trendelenburg hooks must be intact and firmly attached to the tub.
Guardian Bassinet tub should be free of damage.
_____ Warning labels must be intact and legible.
_____ Check mattress for tears, punctures or wear.
Serial number Date PM Completed
Completed by

Guardian Bassinets
12
Guardian Bassinet Service Parts
Part Number Part Name
523-0150-0000 Guardian Bassinet Tub
556-0073-0000 Caster Replacement Kit (4)
530-M028-T000 Drawer Front – Guardian Standard
530-M028-K000 Drawer Front – Guardian Plus
516-0000-0000 Mattress
523-0034-0000 Plastic Chart Holder
558-0002-0000 Plastic Drawer Bin
952-0042-0000 Drawer Frame Bumpers (12)
957-0016-0036 Stainless Steel Bow Pulls

Guardian Bassinets
13
Limited Lifetime Warranty
MedViron®warrants the products it manufactures against defects in material and workmanship
under normal use and service for the expected useful life of the product from the date of
shipment. This limited warranty is valid only to the original purchaser using the product for its
intended purpose. This warranty does not apply to expected changes resulting from normal
wear and tear, use and aging of the product. Specifically excluded from this limited warranty are
defects and damage resulting from abuse, neglect, misuse, or excessive use. Product alteration,
substitution of components or materials, improper cleaning or repair, and installation and
handling damages are also not covered by this warranty. All other express or implied warranties
made by agents, dealers, sales representatives or any other representatives, including any
warranty of merchantability or fitness for a particular purpose, are hereby excluded.
There are no representations as to the capacity or performance of the products sold
hereunder except as set forth in the price list or quotation specifications, if any, and such
representations are expressly conditioned upon the correctness of the data furnished by
purchaser and upon the products being properly installed and maintained.
MedViron’s sole obligation shall be to repair or replace any defective product or product
component covered under this warranty, including shipping and labor, during the warranty period.
In no event shall MedViron be liable for any consequential or incidental damages, including lost
profits or revenues incurred by the purchaser with respect to any goods furnished by MedViron.
Expenses incurred by purchaser in repairing or replacing MedViron product must be pre-approved
in writing by MedViron
In the event a product has to be returned to the factory for verification of a defect and/or repair,
it must be pre-approved in writing by MedViron freight pre-paid, and include a copy of the
original invoice with the date and name of original purchaser.
MedViron hereby assigns to the original owner any and all warranties offered by its component
suppliers. To the extent the terms of these warranties differ from the terms of the Limited
Warranty, the terms of the suppliers’ component warranties shall apply. However, MedViron
does not guarantee that the component supplier will comply with any terms of the warranty of
such supplier.
Any MedViron products with the serial number removed or altered are excluded from this
warranty.
MEDVIRON WILL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES INCLUDING
ANY LOSS, EXPENSE, OR DAMAGE OTHER THAN TO THE PRODUCT ITSELF THAT MAY RESULT FROM
A DEFECT IN THE PRODUCT. SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR LIMITATION OF
CONSEQUENTIAL AND INCIDENTAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY
NOT APPLY.
MEDVIRON MAKES NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. THESE AND ALL OTHER IMPLIED WARRANTIES ARE SPECIFICALLY
DISCLAIMED. SOME STATES DO NOT ALLOW AN EXCLUSION OR LIMITATION ON HOW LONG AN
IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY.
THIS WARRANTY GIVES YOU, THE ORIGINAL PURCHASER, SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO
HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE. EXCEPT FOR SUCH OTHER RIGHTS, THE
REMEDIES PROVIDED UNDER THIS WARRANTY STATE THE LIMIT OF MEDVIRON’S RESPONSIBILITIES.
Table of contents
Other MedViron Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Hitachi
Hitachi C41RP instruction manual

PHILIPS Respironics
PHILIPS Respironics BiPAP A40 Setup guide

Curlin Medical
Curlin Medical PainSmart IOD Addendum to user's manual

Bort
Bort Generation Osteoporosis Brace user manual

Orliman
Orliman MANUTEC M770 Instructions for use

Albrecht
Albrecht MKS LUMBAGO VARIO User instructions