Overview
1
This product is a mobile extra-oral smoke suction machine, which quickly filters spray,
aerosol, bacteria, and other harmful substances during the treatment, by utilizing the high
negative pressure produced by a brushless direct current motor.
The first step is using a way hable primary cotton filter and secondary waterway or
absorbing filter to effectively filter out spray, the in blood, scraps, and other large particles
during the treatment.
The second step is to filter out 99. 97% of the smell and aerosol through customized H13
HEP A highly efficient filter and active carbon filter. The last step is through the UVC photo
oxygen catalytic sterilization module, which sterilizes and expels it to the outside. Tower-
like filters to purify the air. In conclusion, this product can make the air clean and fresh,
improve the cleanliness of the treatment environment, reduce the rate of viral cross
-infection, and thus achieve the goal of fighting infection.
Specifications
Series
Voltage
Power
Air volume
Noise
Filtration
Length of tube
Size
Weight
Size of flange
Air SAFER 80
AC220V 60Hz / AC110V 60Hz
220W
340m3/ h
≤52db(A)
0.3µm 99%
1.4 Meters
L400xW255xH595mm
24kg
75mm
F.D. SA

Product features
CENTRIFUGAL FAN
The fan has a brushless direct current motor with a maximum service life of 40 thousand
hours. Needless to maintenance. High-reliability assurance. Low operating noise. High
rotation speed, high air volume, high air pressure, and high efficiency can be achieved.
LCD DISPLAY
Independently developed microcomputer LCD with programmable single chip bringing
digital control. A simple interface is dis playing operating parameters. The mode of the fan
is automatically checked. When there is pipe blocked, filter saturated, and other situations,
the system will automatically alarm with a signal and a sound. It operates with low-
pressure power to improve safety.
REMOTE CONTROL
This product can remotely control basic on-off instructions, accelerate and decelerate, ti
med shutdown functions. It uses 2.4G wireless technology to achieve 360-degree control
within 20 meters. Easy and convenient operations enable flexibility.
FILTERS
There are five levels and five layers of filter systems: Washable primary effective filter,
water vapor absorbing filter, H13 HEPA filter, active carbon filter, and UVC photo oxygen
catalytic sterilization system.
The first step is using a washable primary cotton filter and secondary water vapor
absorbing filter to effectively filter out spray, thin blood, scraps, and other large particles
during the treatment. The second step is to filter out 99.97% of the smell and aerosol
through customized H13 HEPA highly efficient filter and active carbon filter. The last step
is through the UVC photo oxygen catalytic sterilization module, which sterilizes and expels
it to the outside. Tower-like filters to purify the air.
In conclusion, this product can make the air clean and fresh, improve the cleanliness of the
treatment environment, reduce the rate of viral cross-infection, and thus achieve the goal
of fighting infection.
2
F.D. SA

Packing list
Description QTY Size
Main machine
Power cord
Smoking tube
User’s manual
Washable primary
effective filter
H13 HEPA
Water vapor
absorbing filter
Active carbon filter
UVC lamp
1 set L400xW255xH595mm
1 piece Connect with
machine
1 piece
1.8 meters
1. 4 meters Folding arm
1 book
2 pieces
1 piece
1 piece
1 piece
1 piece
L360xW220xH20mm
L360xW220xH100mm
L360xW220xH50mm
L360xW220xH50mm
10w
Plasma
2.4G
Remote control
1 piece
Foot switch 1 piece
Model
Air-Safer 80
AS01
AS02
AS03
AS04
AS05
AS06
AS07
Note
Options
Options
1 piece
Note: The filter element is placed inside the machine
3
F.D. SA

Filters
Description Replacement period Replacing method
Washable primary
effective filter
1Pull out
Water vapoir
absorbing filter
2Pull out
H13 HEPA3Pull out
Active carbon filter4Pull out
UVC lamp5Pull out
1
2
3
4
5
4
F.D. SA

Structure
1
2
3
4
5
6
7
Air Inlet
Control panel
Lifting handle
Filter’s door
Three-in-one switch
Filters door latch plate
Universal wheel
1 3
4
6
7
5
2
5
F.D. SA

Installation instructions
01.
Insert one end of the power cord to the
tern switch and the other end to an
electrical outlet.
02.
Switch the machine on.
Note: Try to make the nozzle face the
mouth while using the machine to
improve the suction efficiency.
6
F.D. SA

REMOTE TIMED SHUT DOWN
When the machine is running, press
this key to display HXXX on the nixie
tube display screen, and then adjust
the specific time of timing shutdown
according to the increase and decrease
of wind speed, wherein XXX represents
the hours of the timing operation of the
machine, with the maximum of 300
hours and the minimum of 1 hour. After
setting, press the timing key to query
the timing time. The display shows
HXXX. For example, H005 represents
the machine will automatically shut d
own after 5 hours. Set the time to
H000 can eliminate the timing.
Control panel and
remote control
ON/OFF Flow + Flow - Time Set
TIMED SHUTDOWN SETTINGS
When the machine is running, press this key to display the HXXX on the display screen,
and then adjust the specific time of timing shutdown according to the increase and
decrease of wind speed. When setting the timing, press the timing key again to adjust the
shift of the number of times, tens and hundreds. After setting, press the OK setting key to
confirm the end of the timing device. Among them, XXX represents the number of hours
the machine operates at a fixed time, with a maxi mum of 300 hours and a minimum of 1
hour. After setting, press the timing key to query the remaining time of the timing. The
display screen displays HXXX. For example, H005 represents the machine will
automatically shut down after 5 hours. Set the time to H000 can eliminate the timing.
ON/OFF
Flow +
Flow -
Time Set
7

FAQ and solutions
01. The system is still working, but the air volume is weak, and the
suction force is significantly reduced.
Cause: The air intake is blocked, or there is foreign matter in the pipe, and the filter
element reaches saturation failure, resulting in a blocking alarm. Check: turn off the power
supply, check whether there is any foreign matter blocking the air intake, and then check
whether the air out-take is blocked. If the suction of the air compressor is normal, the filter
element needs to be replaced.
02. After the machine starts, it will shut down automatically, repeat the
above phenomenon appear when turning on again.
Cause: The internal airflow is blocked, and the filter element resistance is too large, which
leads to excessive starting current of the fan, and the machine will automatically protect
and shut down. Check: turn off the power supply and check whether there is any foreign
matter blocking the air intake; if there is no abnormality, ad just the air volume to the
minimum, restart the machine and adjust the air volume to the appropriate position.
03. Turn on the power switch and the indicator light is not on
Check whether the socket is in poor contact. If the power socket is in good condition, check
whether the fuse in the power box is burnt. If it is damaged, replace the fuse.
Be sure to cut off the power before checking and repairing the equipment !
8
F.D. SA

Warranty
As for the warranty (free repair) of goods within the warranty period, it
shall be implemented from the date of purchase.
01. During the warranty period, the goods can only be repaired in MegaGen F.D. SA
headquarters or dealers recognized by MegaGen F.D. SA. Please show us this User’s
manual (Warranty) and purchase invoice.
02. From the date of purchase, the main unit is guaranteed for __ __years.
(Note: the filter element belongs to consumables and is not under warranty Scope of
repair)
03. Under one of the foll owing circumstances, even within the warranty period, it can not
be treated as a warranty, but it can be bank charge processing:
A)Damage caused by use, maintenance and storage not under the operating instructions;
B)Damage caused by incorrect operation, abnormal power supply, and falling;
C)Damage caused by dismantling the machine without the consent of the manufacturer;
D)Failure to prove that the machine is within the valid warranty period;
E)The information on the warranty certificate is inconsistent with or altered from the
physical identification of the goods ;
F)Damage due to nuclear and chemical corrosion;
G) Damage due to force measures (lightning, earthquake, flood, fire, and other natural
disasters).
04. MegaGen F.D. SA company reserves the right of final interpretation of after-sales
service terms.
9
F.D. SA

www.megagen.ch
www.megagen.fr
www.imegagen.de
F.D. SA
V 1.0 2020. 04
Table of contents
Other MEGAGEN Dental Equipment manuals
Popular Dental Equipment manuals by other brands

Mikrona
Mikrona MIGMA 200-E PLANNING / MOUNTING GUIDELINES

precisionplus
precisionplus L20 user manual

Dabi Atlante
Dabi Atlante Spectro 70X Series owner's manual

Dentsply Sirona
Dentsply Sirona X-Smart IQ Getting started guide

Vatech
Vatech PaX-i3D Smart installation manual

Renfert
Renfert Millo instruction manual