Error Messages
Lamp error: The unit attempted to strike the lamp more than seven times ithout success, or the lamp is dam-
aged, missing or the unit has overheated several times. This may occur in ambient temperatures of 45ºC and
above. Or it could be failure in the igniter or ballast.
Check or replace lamp. If problem persist contact your dealer
Mother board error: This message indicates that the main PCB is not communicating correctly ith the control
board.
Have a dealer or authorized service center check the unit
Color wheel 1 error: This indicates a problem ith the color heel 1. This could be a defective magnetic indexing
circuit sensor or a bad stepper motor.
Check the connection from PCB to sensor. Confirm magnet is not missing
from color heel. Confirm stepper motor is rotating. Have a dealer or authorized service center check the unit.
Rotating gobo wheel error: The rotating gobo heel is not located in the default position after the reset. This
could be a defective magnetic indexing circuit sensor or a bad stepper motor or a defective driver circuit in the
main PCB.
If problem continues have a dealer or authorized service center check the unit.
Color wheel 2 error: This indicates a problem ith the color heel 2. This could be a defective magnetic indexing
circuit sensor or a bad stepper motor.
Check the connection from PCB to sensor. Confirm magnet is not missing
Rotating gobo indexing error: The rotating gobo is not located in the default position after the reset. This could
be a defective magnetic indexing circuit sensor or a bad stepper motor or a defective driver circuit in the main
PCB.
If problem continues have a dealer or authorized service center check the unit.
Static gobo wheel error: The static gobo is not located in the default position after the reset. This could be a de-
fective magnetic indexing circuit sensor or a bad stepper motor or a defective driver circuit in the main PCB.
If
problem continues have a dealer or authorized service center check the unit.
Prism wheel error: The prism heel is not located in the default position after the reset. This could be a defective
magnetic indexing circuit sensor or a bad stepper motor or a defective driver circuit in the main PCB.
If problem
continues have a dealer or authorized service center check the unit.
Fixture temperature error: This error informs you that the fixture has overheated (occurred if the ambient tem-
perature is 45ºC or more) and the relay has s itched off the lamp. This message ill appear on the display until
the temperature reaches a suitable level, then the display ill sho a HEAt message meaning the lamp is to hot.
You ill need to ait until the lamp has cooled to restart the unit.
Check that fans are orking and heat sensors
are operational. If problems continue have a dealer or authorized service center check the unit.
Power error: This message ill appear if the fixture as shortly disconnected from the mains.
Lamp sensor error: This message appears if the lamp sensor has failed.
If problem occurs have a dealer or au-
thorized service center check the unit.
Tilt movement error: The head is not located in the default position after the reset. This could be a defective mag-
netic indexing circuit sensor or a bad stepper motor or a defective driver circuit in the main PCB.
Check to make
sure that there is nothing obstructing the path, if problem continues have a dealer or authorized service center
check the unit.
Pan movement error: The yoke is not located in the default position after the reset. This could be a defective mag-
netic indexing circuit sensor or a bad stepper motor or a defective driver circuit in the main PCB.
Check to make
sure that there is nothing obstructing the path, if problem continues have a dealer or authorized service center
check the unit.
Frequency error: This message ill appear if the frequency of the main po er is not a standard 50 or 60Hz.
Heat error: This message appears if you try to s itch the lamp on ithin 5 minutes after having turned off the
lamp. The message ill also appear if the lamp doesn’t ignite ithin 28 seconds. The unit ill automatically try to
ignite the lamp again hen 5 minutes have passed.
Check or replace lamp If lamp sensor is s itched off (function
EnSN) this function is disabled. If problem persist contact your dealer or service center.