MODEL SC150 SPECIFICATIONS
INPUT VOLTAGE:
120V 60Hz 1 Phase
220V 60Hz 1 Phase
MAX. CURRENT:
2.4 Amps (at 120V)
1.2 Amps (at 220V)
CFM:
Dual Arm Unit: 200
Single Arm Unit: 150
Sound:
Exhaust: 63 dBA
Inlet: 58 dBA
Measured at 6’
DIMENSIONS: 11-1/4” h. X 14-3/8” w. X 27” l.
ACTUAL WEIGHT:
45-1/2 lbs. Single Arm
47 lbs. Dual Arm
PRE-OPERATING INSTRUCTIONS:
NOTE: The SC150 is shipped in two cartons. Carton one
contains the main unit with instrcutions. Carton two
contains the arm(s) assembly.
1. Upon receipt, remove the units from cartons. Inspect
for any freight damage that may have occured during
shipping. Report any damage to the freight company.
2. Remove filter access door by removing the two phillips
head screws as shown. Grasp the underside of the door
offset and lift slightly to remove (Fig. 1).
3. Looking inside the unit, remove the two (2) filter spring
retainers and pull out the foam prefilter, HEPA filter
and charcoal/purasorb filter. REMOVE THE PLASTIC
WRAP THAT PROTECTS THE CHARCOAL/
PURASORB FILTER DURING STORAGE.
4. Remove the arm assembly from the second carton
consisting of one or two flexible hoses and a black
formed plastic manifold. Taped to the unerside of the
manifold is a clear bag containg four (4) black screws.
Remove screws and disgard the bag.
5. Place the plastic manifold upon the large oval hole on
the SC150 cabinet, align the four pre-drilled holes on
the manifold to those on the cabinte.
6. Using a slot head screw driver, secure the plastic
manifold and hose assembly to the cabinet where the
four (4) self tapping black screws obtained from step
four (Fig. 2).
7. Re-install filters removed in step two and secure with
filter spring retainter. NOTE: filters should be pressed
firmly into unit for positive seal resulting in no filter
bypass. Replace the filter access door.
OPERATION:
1. Before operaating, simply plug the SC150 power cord
into any grounded electrical outlet rated at nameplate
voltage.
2. Once the SC150 has been plugged in, turn the unit on.
Postion inlet nozzel(s) approximately 6” from point of
containment to be captured.
IMPORTANT: TAKE CARE TO SEE THAT
THE INLET NOZZLE(S) DO NOT TOUCH
HOT SURFACES SUCH AS SOLDERING
IRONS, WHICH WOULD RESULT IN THE
DEFORMATION OF THE PLASTIC NOZZLE.
3. The SC150 has a fan-cooled, thermally portected
motor, and is designed to perate for continous duty if
required.
MICRO AIR®SC150
CLEAN AIR SYSTEMS
2
Fig. 1
Fig. 2