M2150
®
MODEL M2150 SPECIFICATIONS
Length: 21” at top
34” at bottom
Width: 19”
Height: 51”
Shipping Weight: 210lbs.
Actualweight: 185lbs.
InputVolts: 115 V, 60 Hz
Max. Current: 8.5 amps @ 115 V.
Motor: 3/4 HP
Arm: 6”dia. 8’ long
PACKAGE CONTENTS
1 Ea. M2150 16 Ea. 5/16” bolt
1Ea. Owner’s Manual 16 Ea. 5/16” hex nut
2Ea.Swivel Caster 16 Ea. FlatWasher
2Ea. Fixed Caster 5/16” Lock Washer
PRE-OPERATING INSTRUCTIONS
1. Afterremoving the cardboard cartonfrom the air cleaner,
removetheplasticwrapping.
2. Openthefilter door and remove the multicellfilterand
pre-filter. Openthe base door andremove the spark tray.
Notethat the casters andhandle are packaged inthe tray.
3. Lay the unit down on its back (the side opposite the arm).
Removethe wooden pallet from theunit.
4. Withtheunitstillin the horizontal position, secure the
casters to the bottom of the unit. (See FIG. 1)
5. Reinstallsparktrayandbasedoor.
6. Slidethe prefilter into thechannels provided at thebottom
oftheunit, making sure that theairflow directional arrows
are pointed upward.
7. Replacethemulticellfilter.
8. Closeandlatch the filter door.
OPERATING INSTRUCTIONS
1. Chooseasuitable level place near theworkstationand
positionthe unit so thatthe arm assembly willbe placed
nearthe source ofpollution being generated.
2. Grasp the hood by the handle and position within 12” of
thesourceof pollution.
3. Plug the power cord into a 115 volt, 60 hertz outlet.
CAUTION:This power cord is supplied with a grounded
type plug. It is intended for use with a grounded outlet,
contact qualified personnel to install the proper outlet.
Do not alter the plug in any way.
4. Turn the switch on.
5. Adjust the hood to capture maximum amount of
contaminants. Periodicallyadjust the positionof the hood
tokeep it inthe maximum capture range.
MAINTENANCE
1. Alwaysbe sure power switchis turned off before
performinganyservice to the air cleaner.
2. Occasionallycheck the condition of thedrive belt for
tightnessandwear.
3. Periodicallycheck the blower wheel fordebris and dirt.
Cleanwhen necessary.
4. Periodicallyinspecthardwarefor loose nuts and bolts on
accessdoorsand internal components. Tighten if
needed.
5. Periodicallyinspectallwiring for loose connections and
crackedinsulation. Replaceasneeded.
TROUBLESHOOTING & REPAIRS
A. Unitfailsto start:
1.Deadpower line: Check circuit and switch.
2.Blown fuse orbreaker: Check fuse or breaker
3. Burned out motor: Replacemotor
B. Unitrunsslowlyorinadequatecapture velocity:
1.Wired for wrongvoltage: Check input voltage
or improper rotation: Switch L1 & L2 to
reverserotation.
Check wiring diagram.
2.Dirtyfilters: Cleanorreplacefilters.
C. Vibration:
1. Loose motor mount bolts: Tightenbolts.
2.Foreign objects inblower: Remove debris
from blower.
3.Dirtydisposablefilters: Servicefilters.
WARRANTY
Metal-Faboffersa limited 2 yearwarranty(from date of
installation)onall replacement parts due tofaultyworkmanship.
Allpatentrightsreserved.