3.After location of the wall mount has been decided, install the
SC150 wall bracket supplied in this kit by mounting to the
wall using the 3 #10 hex screws provided. Note that
source capture arm is 34” long and should be located within
easy reach of area to capture fumes.
CAUTION: WHEN MOUNTING THE WALL BRACKET
TO THE WALLBOARD, BE CERTAIN THAT SCREWS
ARE SECURED TO WALL BOARD VIA WALL JOISTS,
OR BY MEANS OF A THREADED INSERT. WALL
BOARD MATERIAL IS NOT INTENDED TO SOLELY
HOLD WEIGHT OF THE AIR CLEANER.
NOTE: Cord is 8 feet long; unit must be installed within
reach of an electrical outlet.
4.Once the wall bracket and unit bracket are in place, lift the
SC150 and mount to the wall bracket. (FIG. 4.)
C. Optional Wall Mount Assembly for Horizontal Installation.
(FIG. 6)
This installation provides wall brackets that allow the SC150 to be
mounted in a horizontal position.
FIG. 6
SC150 INSTALLATION INSTRUCTIONS
FOR HORIZONTAL WALL MOUNT
APPLICATIONS
This kit (Part No 33086-01) contains:
230151-02 SC150 Wall Mount Brackets
4P103 No. 10 x 1 1/4” Long Hex Screws
1P108 No. 8 x 1/2” Self Tapping Screws
1P1014 Cord Clamp
Refer to FIG. 7 for the following instructions:
1.After location of wall mount bracket has been decided, install
the two (2) mount brackets to wall using the 4-no.10 hex
screws provided. Locate brackets 16” apart as shown.
CAUTION: WHEN MOUNTING WALL BRACKETS TO
WALLBOARD, BE CERTAIN THAT SCREWS ARE
SECURED TO WALL BOARD VIA WALL JOISTS, OR BY
MEANS OF A THREADED INSERT. WALLBOARD
MATERIAL IS NOT INTENDED TO SOLELY HOLD THE
WEIGHT OF THE AIR CLEANER.
NOTE: Cord is 8 feet long. Unit must be
installed within reach of an electrical outlet.
2. Set the SC150 upon wall brackets as shown, making sure
that brackets are located between plastic feet.
3. Once the SC150 is in position as shown, secure the unit to
the wall brackets using the No. 8 x 1/2” sheet metal screw
supplied with this unit.
IMPORTANT: INSTALL SCREW TO EXHAUST END SIDE
AS SHOWN.
MAINTENANCE
1. Normally the HEPA and Charcoal/purasorb filter will be
maintenance free with an average life of about 6 months.
A good indicator for HEPA filter replacement is when air flow is
noticably less than normal and unit has difficulty in capturing
contaminant.
FILTER REPLACEMENT
CAUTION: BE SURE UNIT IS OFF OR UNPLUGGED BEFORE
SERVICING.
1. Remove filter access door. (Refer to step 2, Pre-Operating
Instructions.)
2. Remove filter spring retainers and pull out foam mesh prefilter.
Wash prefilter in a mild detergent. Rinse thoroughly and press
excess water from filter using a towel or cloth.
3. When cleaning the prefilter, inspect the HEPA filter. If
necessary, replace with a new filter. (See parts list for filter part
number.)
4. After approximately 6 months of use, the charcoal purasorb
filter will need to be replaced. Remove the filter by grasping
the tabs attached to each side of the filter and pull out from
unit.
5. Whenever servicing filters, remember to press filter spring
retainers back into prefilter so that gasket of charcoal
purasorb filter is sealed against the cabinet flange. This will
insure total seal against filter to eliminate contaminated air
bypass.
OPTIONAL WALL
BRACKET KIT FOR
HORIZONTAL INSTALLATION.
PART NO. 33086-01