Safety warning information
After receiving the device, please unpacking check whether any visible damage was caused during
transport. lf the power cord housing or the light are damaged, do not operate the device, contact your
specialized dealer or manufacturer immediately.
1),Please read the user manual before energizing or installation.
2),Follow operating safety precautions and pay attention to warning signs methods and
Equipment on the user manual.
Prevent fall to injury
1),When hanging lamps, must verify the lamp hook and facilities at least able to
withstand the weight of the lamp 10 times.
2),Before installation must be verify the install hardware strong enough no other
damage, and the use of safe insurance rope as auxiliary safe way, fixed on the other
facilities.
3),Installing or removing equipment, must be lower the boom to a safe place.
Prevent combustion or fire
1),Please do not install the device directly on the surface of ordinary combustible
material.
2),Don't short sub temperature control protection switch or fuse, must use the
regulation models of fuse.
3),Equipment must be installed away from flammable materials, equipment away from
flammable items or materials shortest distance is 0.5mm.
4),Fan or ventilation at least within the range of 0.3m cannot have obstacles.
5),Allow equipment to cool at least 15 minutes before handling.
2. Packing information
Item Name QTY Unit
The LED par light 1 pcs
Signal wire 1 pcs
Power wire 1 pcs
User manual: 1 pcs

3. Key Description:
MENU: Access the menu
DOWN: "reduction key" or "key under the selected"; decrease the
value function down menu.
UP: "add key" or "selection on the key"; increase the value
function, shift on the menu
ENTER: Is used to select and confirm/store the current selection
4. Menu Display:
No Display
Show
Numerical
Value Function and Description
1 d001 001- 512 DMX512 address setting -10-channel mode
2 A001 001- 512 DMX512 address setting -6-channel mode
3 r255 000 - 255 Red dimming ,from dark to bright
4 G255 000 - 255 Green dimming ,from dark to bright
5 b255 000 - 255 Blue dimming ,from dark to bright
6 u255 000 - 255 White dimming ,from dark to bright
7 Y255 000 - 255 Amber dimming ,from dark to bright
8 P255 000 - 255 UV dimming ,from dark to bright
9 FH99 01 - 99 Strobe,speed from slow to fast
10 CL01 01 - 08 8 kinds of color output.
11 CC01 01 - 99 Color jumping,speed from slow to fast
12 DE99 01 - 99 Color Gradual change,speed from slow to fast
13 CP99 01 - 99 Color Pulse change,speed from slow to fast
14 SU01 01 - 09 mode:1-8 color strobe,9 is color jumping
5. Setting DMX512 console channel address:
After starting DMX512 console, etc. LCD display console initialization has been completed, press Program key,
until the top of the light is flashing, then press the button below channel 1, channel 1 indicator light DMX512
console's address is 10000000, to promote channel faders can be DMX512 console control. Choose DMX512
address consistent with DIP, light to enter the DMX512 control console for the state. The products selected as
10000000 DMX512 console take effect.

6. DMX512 Controller Channel Function:
6 Channel Mode:
10 Channel Mode:
Channel Function Description
CH1 R dimming Red dimming ,from dark to bright
CH2 G dimming Green dimming ,from dark to bright
CH3 B dimming Blue dimming ,from dark to bright
CH4 W dimming White dimming ,from dark to bright
CH5 A dimming Amber dimming ,from dark to bright
CH6 UV dimming UV dimming ,from dark to bright
Channel Function Description
CH1 Master Dimmer RGBWAUV master dimmer, from dark to bright
CH2 R dimming Red dimming ,from dark to bright
CH3 G dimming Green dimming ,from dark to bright
CH4 B dimming Blue dimming ,from dark to bright
CH5 W dimming White dimming ,from dark to bright
CH6 A dimming Amber dimming ,from dark to bright
CH7 UV dimming UV dimming ,from dark to bright
CH8 Master strobe RGBWAUV master strobe ,from slow to fast
CH9 Function selection
0—50:controlled by CH1-CH8;
51-100:8 kinds of color output.;
101—150:Color jumping;
151—200:Color Gradual change;
201—250:Color Pulse change;
251-255:Sound control
CH10 Function speed Function speed from slow to fast (Color output when the
color selection)

7. The Special Function
Long press the "MENU" button does not release until "0000" and the first flash, then release the button, press
the "MENU" switch function number, use UP or DOWN keys to select, press ENTER to save the settings and
exit
No Display
Show
Numerical
Value Function and Description
1 000 000 Off all lights
2 r255 000 - 255 Red channel current setting, from small to large, from dark to
bright
3 G255 000 - 255 Green channel current setting, from small to large, from dark to
bright
4 b255 000 - 255 Blue channel current setting, from small to large, from dark to
bright
5 u255 000 - 255 Red channel current setting, from small to large, from dark to
bright
6 Y255 000 - 255 Amber channel current setting, from small to large, from dark to
bright
7 P255 000 - 255 UV channel current setting, from small to large, from dark to
bright
8 rGbu - Full bright
9 py32 - Program Version
10 nod1 1/2
When the channel mode display nod2 mode: the Channel
function is :
1 Total dimming, 2 strobe , 3 function, 4 function Speed, 5 red, 6
green, 7 blue, 8 white, 9 amber , 10 UV
11 P235 50-255
After the lamp PCB plate temperature reaches 70 degrees, the
LED lamp 's reduced power rate is : as set 200: current
(brightness) = 200/255 = 78%
12 Ft50 45-70
Temperature setting when fan at full speed , when the
temperature is below 15 degrees, the fan will start.
If below the set value 5 degrees, the fan speed will be reduced
one rank

8. Cleaning and Maintenance
CAUTION!
Disconnect from main power before starting maintenance operation!
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics.
1) Clean with soft cloth using normal glass cleaning fluid.
2) Always dry the parts carefully.
3) Clean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days.
9. Specification:
Rated voltage: 95V-240VAC, 50/60Hz
Power Consumption:144W
Lamp:12*12W RGBWA+UV(6 in 1) LEDs
Bean angel:150
DMX512 Channels: 6/10CH
Waterproof Grade: IP65
Dimming:0-100%
Cooling system: Convection
Function: Auto-run feature, DMX-512 control console, Voice-activated functions
Fixtures Size:215x215x120mm
Gross Weight:8KG
This unit is covered by a 2 Year Manufacturer’s warranty. Please contact the store you purchased this
unit to arrange any warranty repairs. Please keep your invoice to show proof of purchase date.
Table of contents
Other Microh Floodlight manuals

Microh
Microh Ultra Beam 700 User manual

Microh
Microh LED NOVA 4 User manual

Microh
Microh LED NEO SPOT 60R User manual

Microh
Microh RIO TRI PAR User manual

Microh
Microh LED MAX ZOOM RGB User manual

Microh
Microh Ultra beam 300WI User manual

Microh
Microh LED HALO BEAM710 User manual

Microh
Microh ARENA ultra spot User manual

Microh
Microh LED Slim P7 User manual

Microh
Microh Titan RGB 1.5 User manual