MEES21K001
PEFY-P-NMAU-E4
3
1. SPECIFICATIONS Ceiling concealed (Medium static pressure type)
Model PEFY-P18NMAU-E4 PEFY-P24NMAU-E4 PEFY-P27NMAU-E4 PEFY-P30NMAU-E4
Power source 1-phase 208/230 V 60 Hz 1-phase 208/230 V 60 Hz 1-phase 208/230 V 60 Hz 1-phase 208/230 V 60 Hz
Cooling capacity *1 BTU/h 18,000 24,000 27,000 30,000
(Nominal) *1 kW 5.3 7.0 7.9 8.8
*2 Power input kW 0.082 0.142 0.142 0.142
*2 Current input A 0.82/0.74 1.24/1.12 1.24/1.12 1.24/1.12
Heating capacity *3 BTU/h 20,000 27,000 30,000 34,000
(Nominal) *3 kW 5.9 7.9 8.8 10.0
*2 Power input kW 0.080 0.140 0.140 0.140
*2 Current input A 0.82/0.74 1.24/1.12 1.24/1.12 1.24/1.12
External finish Galvanized steel plate Galvanized steel plate Galvanized steel plate Galvanized steel plate
External dimension H x W x D inch 9-7/8 x 35-7/16 x 28-7/8 9-7/8 x 43-5/16 x 28-7/8 9-7/8 x 43-5/16 x 28-7/8 9-7/8 x 43-5/16 x 28-7/8
mm 250 x 900 x 732 250 x 1,100 x 732 250 x 1,100 x 732 250 x 1,100 x 732
Net weight lbs (kg) 58 (26) 67 (30) 67 (30) 67 (30)
Heat exchanger Cross fin (Aluminum fin and
copper tube)
Cross fin (Aluminum fin and
copper tube)
Cross fin (Aluminum fin and
copper tube)
Cross fin (Aluminum fin and
copper tube)
FAN Type x Quantity Sirocco fan x 2 Sirocco fan x 2 Sirocco fan x 2 Sirocco fan x 2
*4 External static press. in.WG <0.14> - 0.20 - <0.28> -
<0.40> - <0.60>
<0.14> - 0.20 - <0.28> -
<0.40> - <0.60>
<0.14> - 0.20 - <0.28> -
<0.40> - <0.60>
<0.14> - 0.20 - <0.28> -
<0.40> - <0.60>
Pa <35> - 50 - <70> - <100> -
<150>
<35> - 50 - <70> - <100> -
<150>
<35> - 50 - <70> - <100> -
<150>
<35> - 50 - <70> - <100> -
<150>
Motor Type DC motor DC motor DC motor DC motor
Motor output kW 0.121 0.121 0.121 0.121
Driving mechanism Direct-driven by motor Direct-driven by motor Direct-driven by motor Direct-driven by motor
Air flow rate (Low-Mid-High) (Low-Mid-High) (Low-Mid-High) (Low-Mid-High)
cfm 424 - 512 - 600 618 - 742 - 883 618 - 742 - 883 618 - 742 - 883
m3/min 12.0 - 14.5 - 17.0 17.5 - 21.0 - 25.0 17.5 - 21.0 - 25.0 17.5 - 21.0 - 25.0
L/s 200 - 242 - 283 292 - 350 - 417 292 - 350 - 417 292 - 350 - 417
Sound pressure level (measured in anechoic room) (Low-Mid-High) (Low-Mid-High) (Low-Mid-High) (Low-Mid-High)
*2 dB <A> 29-33-37 31-35-39 31-35-39 31-35-39
Insulation material EPS, Polyethylene foam, Ure-
thane foam
EPS, Polyethylene foam, Ure-
thane foam
EPS, Polyethylene foam, Ure-
thane foam
EPS, Polyethylene foam, Ure-
thane foam
Air filter PP honeycomb fabric. PP honeycomb fabric. PP honeycomb fabric. PP honeycomb fabric.
Protection device Fuse Fuse Fuse Fuse
Refrigerant control device LEV LEV LEV LEV
Connectable outdoor unit R410A CITY MULTI R410A CITY MULTI R410A CITY MULTI R410A CITY MULTI
Diameter of Liquid (R410A) inch (mm) 1/4 (6.35)Brazed 3/8 (9.52)Brazed 3/8 (9.52)Brazed 3/8 (9.52)Brazed
refrigerant pipe Gas (R410A) inch (mm) 1/2 (12.7)Brazed 5/8 (15.88)Brazed 5/8 (15.88)Brazed 5/8 (15.88)Brazed
Field drain pipe size inch (mm) O.D.1-1/4 (32) O.D.1-1/4 (32) O.D.1-1/4 (32) O.D.1-1/4 (32)
Drawing External KB94C2RE KB94C2RE KB94C2RE KB94C2RE
Wiring KB94C2Y4 KB94C2Y4 KB94C2Y4 KB94C2Y4
Refrigerant cycle - - - -
Standard attachment Document Installation Manual, Instruction
Book
Installation Manual, Instruction
Book
Installation Manual, Instruction
Book
Installation Manual, Instruction
Book
Accessory Washer, Drain hose, Tie band Washer, Drain hose, Tie band Washer, Drain hose, Tie band Washer, Drain hose, Tie band
Optional parts External heater adapter PAC-YU25HT PAC-YU25HT PAC-YU25HT PAC-YU25HT
Filter box PAC-KE92TB-E PAC-KE93TB-E PAC-KE93TB-E PAC-KE93TB-E
Remarks * Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred
to the Installation Manual.
* Due to continuing improvement, above specifications may be subject to change without notice.
Notes: Unit converter
1.Nominal cooling conditions
Indoor: 80°FD.B./67°FW.B. (26.7°CD.B./19.4°CW.B.), Outdoor: 95°FD.B. (35°CD.B.)
Pipe length: 25 ft. (7.6 m), Level difference: 0 ft. (0 m)
2.The values are measured at the factory setting of external static pressure.
3.Nominal heating conditions
Indoor: 70°FD.B. (21.1°CD.B.), Outdoor: 47°FD.B./43°FW.B. (8.3°CD.B./6.1°CW.B.)
Pipe length: 25 ft. (7.6 m), Level difference: 0 ft. (0 m)
4.The factory setting of external static pressure is shown without < >.
Refer to "Fan characteristics curves", according to the external static pressure, in DATA BOOK for the usable
range of air flow rate.
BTU/h =kW x 3,412
cfm =m3/min x 35.31
lbs =kg/0.4536
*Above specification data is
subject to rounding variation.
0000006261.BOOK 3 ページ 2021年4月20日 火曜日 午後2時35分