FOR INSTALLER
1
en
1. BEFORE INSTALLATION
Required Tools for Installation
ENGLISH
CONTENTS
1. BEFORE INSTALLATION ............................................................ 1
2. OUTDOOR UNIT INSTALLATION ............................................... 7
3. FLARING WORK AND PIPE CONNECTION............................... 8
4. PURGING PROCEDURES, LEAK TEST, AND TEST RUN......... 9
5. PUMPING DOWN ...................................................................... 12
1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
• Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.
Do not install the unit by yourself (user).
Perform the installation securely referring to the installation manual.
When installing the unit, use appropriate protective equipment and tools
for safety.
Install the unit securely in a place which can bear the weight of the unit.
If the installation location cannot bear the weight of the unit, the unit could fall
not connect other electrical appliances to the circuit.
screws.
Be sure to cut off the main power in case of setting up the indoor P.C. board
or wiring works.
or use intermediate connection.
sion.
and do not connect many devices to one AC outlet.
When plugging the power supply plug into the outlet, make sure that there
is no dust, clogging, or loose parts in both the outlet and the plug. Make
sure that the power supply plug is pushed completely into the outlet.
plug, replace it.
Attach the electrical cover to the indoor unit and the service panel to the
outdoor unit securely.
dust, water, etc.
When installing, relocating, or servicing the unit, make sure that no sub-
Do not discharge the refrigerant into the atmosphere. If refrigerant leaks
during installation, ventilate the room. Check that the refrigerant does not
leak after installation has been completed.
Check that the refrigerant gas does not leak after installation has been
completed.
Use appropriate tools and piping materials for installation.
When pumping down the refrigerant, stop the compressor before discon-
necting the refrigerant pipes.
When installing the unit, securely connect the refrigerant pipes before start-
ing the compressor.
the stop valve is open, air could be drawn in and the pressure in the refrigeration
The unit shall be installed in accordance with national wiring regulations.
Earth the unit correctly.
Do not connect the earth to a gas pipe, water pipe, lightning rod or telephone
Be sure to install an earth leakage breaker.
remove all of the refrigerant from the air conditioner and ensure that the
area is well-ventilated.
Do not use means to accelerate the defrosting process or to clean, other
than those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating
an operating electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Pipe-work shall be protected from physical damage.
The installation of pipe-work shall be kept to a minimum.
Compliance with national gas regulations shall be observed.
Keep any required ventilation openings clear of obstruction.
Do not use low temperature solder alloy in case of brazing the refrigerant
pipes.
Servicing shall be performed only as recommended by the manufacturer.
When opening or closing the valve below freezing temperatures, refrigerant
may spurt out from the gap between the valve stem and the valve body,
WARNING
MEANINGS OF SYMBOLS DISPLAYED ON INDOOR UNIT AND/OR OUTDOOR UNIT
WARNING
Phillips screwdriver
Level
Scale
Torque wrench