FOR INSTALLER
1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
• Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.
Do not install the unit by yourself (user).
installer.
Perform the installation securely referring to the installation manual.
When installing the unit, use appropriate protective equipment and tools for
safety.
Install the unit securely in a place which can bear the weight of the unit.
not connect other electrical appliances to the circuit.
screws.
Be sure to cut off the main power in case of setting up the indoor P.C. board
or wiring works.
intermediate connection.
and do not connect many devices to one AC outlet.
When plugging the power supply plug into the outlet, make sure that there is
no dust, clogging, or loose parts in both the outlet and the plug. Make sure
that the power supply plug is pushed completely into the outlet.
it.
Attach the electrical cover to the indoor unit and the service panel to the
outdoor unit securely.
If the electrical cover of the indoor unit and/or the service panel of the outdoor unit are
etc.
When installing, relocating, or servicing the unit, make sure that no sub-
Do not discharge the refrigerant into the atmosphere. If refrigerant leaks dur-
ing installation, ventilate the room. Check that the refrigerant does not leak
after installation has been completed.
accordance with EN378-1.
Check that the refrigerant gas does not leak after installation has been com-
pleted.
Use appropriate tools and piping materials for installation.
When pumping down the refrigerant, stop the compressor before disconnect-
ing the refrigerant pipes.
When installing the unit, securely connect the refrigerant pipes before start-
ing the compressor.
The unit shall be installed in accordance with national wiring regulations.
Earth the unit correctly.
Be sure to install an earth leakage breaker.
remove all of the refrigerant from the air conditioner and ensure that the area
is well-ventilated.
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating
operating electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Pipe-work shall be protected from physical damage.
The installation of pipe-work shall be kept to a minimum.
Compliance with national gas regulations shall be observed.
Keep any required ventilation openings clear of obstruction.
Do not use low temperature solder alloy in case of brazing the refrigerant
pipes.
Servicing shall be performed only as recommended by the manufacturer.
WARNING
Required Tools for Installation
Level
Scale
ENGLISH
CONTENTS
1. BEFORE INSTALLATION ............................................................ 1
2. OUTDOOR UNIT INSTALLATION ...............................................7
...............................8
.........9
...................................................................... 11
1. BEFORE INSTALLATION
MEANINGS OF SYMBOLS DISPLAYED ON INDOOR UNIT AND/OR OUTDOOR UNIT
WARNING