manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Mitsubishi Electric
  6. •
  7. DC Drive
  8. •
  9. Mitsubishi Electric FR-D700 Series User manual

Mitsubishi Electric FR-D700 Series User manual

Distributor for:
Frequency inverter
FR-D700
Instruction manual
Quick set-up guide
EPA Drives
Thank you for choosing to work with EPA!
EPA - your competent partner for Mitsubishi Electric when it comes to individual service &
comprehensive services.
If you have any questions about the product, please feel free to call us: Tel: +49 (0)6181 - 9704 - 0
You can nd the latest information about us and our products at www.epa.de.
Sales department: EPA GmbH
Fliederstraße 8, D-63486 Bruchköbel
Deutschland / Germany
Telefon / Phone: +49(0)6181 9704-0
Telefax / Fax: +49(0)6181 9704-99
E-Mail: [email protected]
Internet: www.epa.de
Author: MITSUBISHI ELECTRIC AUTOMATION UK
Release: B / 01.2014
Article: FR-D700
Mitsubishi D700 inverter quick set-up guide
Mitsubishi inverters are factory set for EXTernal control.
When a START signal is connected across the STF-PC input terminals the inverter will run to a
speed set by a potentiometer on terminals 10, 2, and 5, see below.
When START is pressed the FWD run status LED should flash and the Hz display increase.
To change parameters
1) Change to PU operation ( )
2) Scroll to select the parameter
3) Press SET to display the current value
4) Scroll to change the value
5) Press SET button to write the value
Basic Parameters, the
A B C
A B CA B C
A B C
Mitsubishi Electric Motor
SF-JR160 15kW 4Pole
Frequency 50Hz
Motor Amps 29.2A
Voltage 415V
Pr.19
V
f
Pr.14=0
Pr.14=1
Pr.3
Pr.1 & Pr,2 Maximum & Minimum speeds (Hz)
Pr.7 & Pr.8 Acceleration & Deceleration time(sec)
Match the inverter output to the load duty -
Pr.14 = 0 for all general applications
Pr.14 = 1 for clean water pumps, fans etc
For better motor and system efficiency -
Pr.60 = 9 for Energy saving control selection
Enter the details from the motor nameplate
Pr.3 Rated frequency
(50Hz as default)
Pr.9 Rated current
(Inverter max as default)
Pr.19 Rated voltage
(Same as V
IN
as default)
Check list :-
The EXT LED should be ON (PU is Parameter Unit mode for set-up).
Use the correct common for the control signals, PC is the default, not SD.
The inverter will not run if the MRS signal is connected.
Control mode Parameter Pr.79 is set to either 0 or 2 for EXT control.
10
2 (swipe)
5
Potentiometer
+
-
Run status
PU to EXT key
Control Mode
Display Hz/A/V
Note - Mode change only possible when motor stopped.
Parameter setting only possible in PU mode.
A
AA
A
- Motor details
B
BB
B
- Load type
C
CC
C
- Basic operational settings
Frequency / Speed
t
Pr.7 Pr.8
Pr.2
Pr.1
Operation
Zone
Run and Stop
Note : Set Pr. 160 Extended function = 0
Note : These parameters have been and are the same for all Mitsubishi inverters.
Mitsubishi D700 inverter quick set-up guide
Alarm History
The previous EIGHT alarms are retrievable using the keypad
To access the Alarm menu
Press the mode button twice - E--- is displayed
Scroll through the alarm History
Press SET to read the Hz, Amps, Volts and hrs ON for each
alarm.
The inverter PC software “FR-Configurator V3” supports
diagnosis and setup for FR-D700.
General causes of alarms
For full information on alarm codes, please refer to the installation manual for the specific inverter.
Inverter Overload
Over current (OC1, OC2), and transistor thermal alarms (THT) are caused by too much current flowing in the inverter transistor circuits.
CHECK - Monitor the current during start-up and running.
1. E.OC1 Immediate over-current - output short-circuit or already rotating motor.
2. E.OC1 Over-current after 1 second - stalled motor, jammed motor, high friction,
Pr.14 may be incorrectly set to 1, torque boost (Pr.0) set too high
3. E.OC1 Overload after half speed - high inertia, acceleration (Pr.7) too fast, torque
level too low as Pr.14 may be set to 1.
4. E.OC2 Overload at steady speed - high motor current, sudden load increase,
incorrect pump rotation, single-phasing of the output.
Motor thermal overload
Pr.9 is set to the motor rated current. The inverter calculates the level of current at reduced speeds that will cause a temperature build-up in
the motor. If the E.THM alarm occurs but the motor is NOT hot, then the value can be increased to avoid nuisance tripping.
CHECK - Pr.0 - should be set as low as possible, while still allowing the motor to start
Pr.14 - can be set to 1 for clean water pumps
For a high load and low speed operation extra ventilation on the motor and Pr.71=1 can be used.
NOTE - This guide is designed as a simple guide and is not designed to replace the technical information in the product manuals.
For further help - Technical Help Desk 01707 278990 www.mitsubishi-automation.co.uk automation.support@meuk.mee.com
Note - Alarm code and Hz, V and A information is important for diagnosis.
E.0 indicates there are no alarms.
Hz
t
1 2 3 4
SET
SET

Other manuals for FR-D700 Series

9

Other Mitsubishi Electric DC Drive manuals

Mitsubishi Electric F700 User manual

Mitsubishi Electric

Mitsubishi Electric F700 User manual

Mitsubishi Electric FR-800 Series User manual

Mitsubishi Electric

Mitsubishi Electric FR-800 Series User manual

Mitsubishi Electric FR-F 700 EC User manual

Mitsubishi Electric

Mitsubishi Electric FR-F 700 EC User manual

Mitsubishi Electric FR-F740-00023-EC User manual

Mitsubishi Electric

Mitsubishi Electric FR-F740-00023-EC User manual

Mitsubishi Electric FR-F500 Series User manual

Mitsubishi Electric

Mitsubishi Electric FR-F500 Series User manual

Mitsubishi Electric MR-J5W-B User manual

Mitsubishi Electric

Mitsubishi Electric MR-J5W-B User manual

Mitsubishi Electric FR-D720-0.2K-G User manual

Mitsubishi Electric

Mitsubishi Electric FR-D720-0.2K-G User manual

Mitsubishi Electric FR-A800 User manual

Mitsubishi Electric

Mitsubishi Electric FR-A800 User manual

Mitsubishi Electric FR-A500 Series User manual

Mitsubishi Electric

Mitsubishi Electric FR-A500 Series User manual

Mitsubishi Electric FR-E500 Series User manual

Mitsubishi Electric

Mitsubishi Electric FR-E500 Series User manual

Mitsubishi Electric FR-E800-SCEPA User manual

Mitsubishi Electric

Mitsubishi Electric FR-E800-SCEPA User manual

Mitsubishi Electric fr-e700 series User manual

Mitsubishi Electric

Mitsubishi Electric fr-e700 series User manual

Mitsubishi Electric D700-SC Instructions for use

Mitsubishi Electric

Mitsubishi Electric D700-SC Instructions for use

Mitsubishi Electric FR-A 500 User manual

Mitsubishi Electric

Mitsubishi Electric FR-A 500 User manual

Mitsubishi Electric FR-A700 Series User manual

Mitsubishi Electric

Mitsubishi Electric FR-A700 Series User manual

Mitsubishi Electric QnA Series User manual

Mitsubishi Electric

Mitsubishi Electric QnA Series User manual

Mitsubishi Electric FR-A741-5.5K Instruction sheet

Mitsubishi Electric

Mitsubishi Electric FR-A741-5.5K Instruction sheet

Mitsubishi Electric FR-D720S SC EC User manual

Mitsubishi Electric

Mitsubishi Electric FR-D720S SC EC User manual

Mitsubishi Electric FR-CS82S User manual

Mitsubishi Electric

Mitsubishi Electric FR-CS82S User manual

Mitsubishi Electric Melservo-Jet MR-JET-G User manual

Mitsubishi Electric

Mitsubishi Electric Melservo-Jet MR-JET-G User manual

Mitsubishi Electric FR-PU07 Instruction manual

Mitsubishi Electric

Mitsubishi Electric FR-PU07 Instruction manual

Mitsubishi Electric FR-A5NPA User manual

Mitsubishi Electric

Mitsubishi Electric FR-A5NPA User manual

Popular DC Drive manuals by other brands

National Instruments NI MID-7604 user guide

National Instruments

National Instruments NI MID-7604 user guide

SOMFY Maestria WT Series instructions

SOMFY

SOMFY Maestria WT Series instructions

Danfoss VLT HVAC Design guide

Danfoss

Danfoss VLT HVAC Design guide

Trane TR150 Service manual

Trane

Trane TR150 Service manual

Chamberlain Garog D Series operating manual

Chamberlain Garog

Chamberlain Garog D Series operating manual

Parker PDS Series user guide

Parker

Parker PDS Series user guide

Binks QS-5012-1-CE Service manual

Binks

Binks QS-5012-1-CE Service manual

Danfoss VLT 2800 Series Quick setup

Danfoss

Danfoss VLT 2800 Series Quick setup

YASKAWA CANopen SI-S3 Technical manual

YASKAWA

YASKAWA CANopen SI-S3 Technical manual

GE D20A6 instructions

GE

GE D20A6 instructions

Danfoss VLT AQUA Drive FC 202 operating manual

Danfoss

Danfoss VLT AQUA Drive FC 202 operating manual

Lenze PositionServo 940 user manual

Lenze

Lenze PositionServo 940 user manual

Unex MC-D-250-1000-050W-TW operating manual

Unex

Unex MC-D-250-1000-050W-TW operating manual

Geckodrive G213V manual

Geckodrive

Geckodrive G213V manual

ABB RSYC-01 user manual

ABB

ABB RSYC-01 user manual

Rockwell Automation PowerFlex 700S Programming manual

Rockwell Automation

Rockwell Automation PowerFlex 700S Programming manual

WEG DeviceNet CFW500 user manual

WEG

WEG DeviceNet CFW500 user manual

Siemens SINAMICS G List manual

Siemens

Siemens SINAMICS G List manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.