1-7
Model SRK408HENF-L3 (Indoor unit)
SRC408HENF-L3 (Outdoor unit)
Item Model SRK408HENF-L3 SRC408HENF-L3
Cooling c p city(1) W 3500/3500
He ting c p city(1) W 4100/4100
Power source 1 Ph se, 220/240V, 50Hz
Cooling input kW 1.320/1.405
Running current (Cooling) A 6.4/6.4
He ting input kW 1.335/1.460
Running current (He ting) A 6.5/6.5
Inrush current A 33.6/36.6
COP (In cooling) 2.65/2.49
Cooling Sound level Hi : 40/42 Lo : 31/32 47/49
Noise level Power level dB Hi : 54/56 Lo : 45/46 61/63
He ting Sound level Hi : 41/43 Lo : 39/40 48/50
Power level Hi : 55/57 Lo : 53/54 62/64
Exterior dimensions
Height x Width x Depth mm 275 x 790 x 174 542 x 795 x 255
Color Ivory white Polar white
Net weight kg 8 37
Refriger nt equipment
Compressor type & Q’ty –RM5516GNVE4 (Rot ry type) x 1
Motor kW –1.3
St rting method – Line starting
He t exch nger Louver fins & bare tubing
Refriger nt control Capillary tubes
Refriger nt(4) kg R22 1.3
Refriger nt oil R0.6 (BARREL FREEZE 32SAM)
Defrost control MC control
Air h ndling equipment
F n type & Q’ty Tangential fan x 1 Propeller fan x 1
Motor W 16 18
Air flow ( t High) (Cooling) 8.5/8.5 22/22.5
(He ting) CMM 9.5/9.5 22/22.5
Air filter, Q’ty Polypropylene net (washable) x 2 –
Shock & vibr tion bsorber – Cushion rubber (for compressor)
Oper tion control
Oper tion switch Wireless–Remote controller –
Room temper ture control MC. Thermostat –
Pilot l mp R N (Green), TIMER (Yellow) –
S fety equipment –Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
O.D mm(in) Liquid line: ø6.35 (1/4") G s line: ø12.7 (1/2")
Connecting method Fl re connecting
Att ched length of piping Liquid line: 0.4m G s line : 0.35m –
Insul tion Necess ry (Both sides)
Dr in hose Connect ble
Power source cord 2.5m (3 cores with E rth)
Connection Size x Core number 1.5mm2 x 5 cores (Including e rth c ble)
wiring Connecting method Termin l block (Screw fixing type)
Accessories (included) Mounting kit
Option l p rts –
Notes (1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
Heating 20ºC – 7ºC 6ºC ISO-T1, JIS C9612
(2) The operation data are applied to the 220V or 240V districts respectively
(3) The refrigerant quantity to be charged includes the refrigerant in 7.5m connecting piping. (Purging is not required even in the short piping.)
If the piping length is longer, when it is 10 m, add 20g refrigerant per meter and when it is 10 to 15m, add 30g refrigerant per meter.
(4) When the unit is operated in cooling or dehumidification mode at the outside air temperature of 1ºC and less, there is a possibility that water leakage
occurs at the indoor unit.
Oper tion d t
(1)
Refriger nt
piping