Connections
1. Before installation, the cold water angle valve should be closed;
2. According to the installation diagram (figure 2), connect the tap water to the water inlet
of the main engine, such as (line-01);
3. Connect the purification water port of the main unit to the corresponding port of the blue
switch of the faucet (2 points through connector), such as (line-02);
4. Connect the pure water port (identification—connecting to the faucet) to the corresponding
port of the red switch of the faucet (2 points through connector) Connect the tube from
the waste water outlet to the floor drain sewer.
Commissioning
Ensure that the tubing is well connected and open the water inlet valve;
Flush the whole machine: turn on the mineral water switch of the faucet, and flush for 5
minutes until water drips out of the faucet, and the residual air in the whole machine is
discharged; Complete machine flushing: turn on the tap and run water for 15 minutes to flush
the filter; Whole machine water: The whole machine can be used after 15 minutes of flushing;
Test the TDS value to verify the filtering effect (Reminder: Due to the different water quality
and temperature of water sources in different places, the length of flushing time will also
be different)
The indicator light of filter (I) corresponds to the first-stage filter, the indicator light of filter (II)
corresponds to the second-stage filter, and the indicator light of filter (III) corresponds to
the third-stage filter. When the life of the filter expires, the corresponding light will go out.
Replace the filter and commission after replacement.
Figure 3 - Digital Display
THE COMMISSIONING METHOD IS AS FOLLOWS
1: Double-click the STE location, and the extinguished No. 1 filter indicator light is now on.
After the light is on, the life of the first stage filter is reset.
2: Double-click the STE location again, at this time the extinguished No. 2 filter indicator
light is on, after the light is on, the life of the second stage filter is reset
3: Continue to double-click STE again, at this time the extinguished No. 3 filter indicator l
ight is on, after the light is on, the third stage filter reset is completed