Morris MOR20L-DHE User manual

!
INSTRUCTION MANUAL
MOR20L-DHE
Please keep this manual safe for future reference!
Thank you for selecting our dehumidifier. Be sure to read this manual carefully
before using it. Any questions, please get in touch!

2
CONTENT
1. BEFORE YOU BEGIN.................................................03
2. FOR YOUR SAFETY....................................................05
3. PRODUCT OVERVIEW...............................................09
4. INSTALLATION..........................................................11
5. OPERATION..............................................................13
6. MAINTENANCE.........................................................16
7. TROUBLESHOOTING................................................19
8. DECOMMISSIONING.................................................20

3
1. BEFORE YOU BEGIN
Please read the operating instructions carefully before using your
dehumidifier for the first time.
1.1 PRODUCT DESCRIPTION
The dehumidifier is used to remove excessive moisture from the air. The
resulting reduction in relative humidity protects buildings and their contents
from the adverse effects of excess humidity.
The environmentally friendly R290 is used as the refrigerant. R290 has no
damaging influence on the ozone layer (ODP), a negligible greenhouse effect
(GWP) and is available worldwide. Because of its efficient energy properties,
R290 is highly suitable as a coolant for this application. Special precautions
must be taken into consideration due to the coolant's high flammability.
1.2 SYMBOLS FROM THE UNIT AND USER MANUAL
This unit uses a flammable refrigerant.
If refrigerant leaks and comes in contact with fire or
heating part, it will create harmful gas and there is risk of
fire.
Read the USER MANUAL carefully before operation.
Further information is available in the USER MANUAL,
SERVICE MANUAL, and the like.
Service personnel are required to carefully read the USER
MANUAL and SERVICE MANUAL before operation.
%
warning

4
1.2 THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
●This appliance is intended to be used by expert or trained users in
shops, in light industry and on farms, or for commercial use by lay
persons.
●This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by
children without supervision.
●The unit is designed only for use with R-290(propane) gas as the
designated refrigerant.
●The refrigerant loop is sealed. Only a qualified technician should
attempt to service!
●Do not discharge the refrigerant into the atmosphere.
●R-290 (propane) is flammable and heavier than air.
●It collects first in low areas but can be circulated by the fans.
●If propane gas is present or even suspected, do not allow untrained
personnel to attempt to find the cause.
●The propane gas used in the unit has no odor.
●The lack of smell does not indicate a lack of escaped gas.
●If a leak is detected, immediately evacuate all persons from the store,
ventilate the room and contact the local fire department to advise them
that a propane leak has occurred.
●Do not let any persons back into the room until the qualified service
technician has arrived and that technician advises that it is safe to
return to the store.
●No open flames, cigarettes or other possible sources of ignition should
be used inside or in the vicinity of the units.
●Component parts are designed for propane and non-incentive and non-
sparking. Component parts shall only be replaced with identical repair
parts.
FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION,
DEATH, INJURY AND PROPERTY DAMAGE

5
2. FOR YOUR SAFETY
Your safety is the most important thing to us!
Please read this manual carefully and fully understand before
operating your dehumidifier.
2.1 OPERATIONAL PRECAUTIONS
WARNING- to reduce the risk of fire, electric shock or injury to persons or
property:
●If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
●The A-weighted sound pressure level is below 43 dB.
●The appliance shall be disconnected from its power source during
maintenance.
●Always operate the unit from a power source of equal voltage, frequency
and rating as indicated on the product identification plate.
●Always use a power outlet that is grounded.
●Unplug the power cord when cleaning or when not in use.
●Do not operate with wet hands. Prevent water from spilling onto the unit.
●Do not immerse or expose the unit to rain, moisture or any other liquid.
●Do not tilt or turn over the unit.
●Do not unplug while the unit is operating.
●Do not unplug by pulling on the power cord.
●Do not use an extension cord or an adapter plug.
●Do not put objects on the unit.
●Do not climb or sit on the unit.
●Do not insert fingers or other objects into the air outlet.
●Do not touch the air inlet or the aluminum fins of the unit.
●Do not operate the unit if it is dropped, damaged or showing signs of
product malfunction.
●Do not clean the appliance with any chemicals.
●Ensure the unit is far away from fire, inflammable, or explosive objects.
●The unit shall be installed in accordance with national wiring regulations.
●Do not use means to accelerate the defrosting process or to clean, other
than those recommended by the manufacture.

6
●The appliance shall be stored in a room without continuous operation
sources (for example: open flames, an operating gas appliance or an
operating electric heater).
●The appliance shall be stored so as to prevent mechanical damage from
occurring.
●Do not piece or burn, even after use.
●Be aware that refrigerants may not contain an odour.
●Pipe-work shall be protected from physical damage and shall not be
installed in an unventilated space, if that space is smaller than 4 m².
●Compliance with national gas regulations shall be observed.
●Keep any required ventilation openings clear of obstruction.
●The appliance shall be stored in a well-ventilated area where the room
size corresponds to the room area as specified for operation.
Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certificate from an industry-
accredited assessment authority, which authorizes their competence to handle
refrigerants safely in accordance with an industry, recognized assessment
specification.
Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other skilled
personnel shall be carried out under the supervision of the person competent
in the use of flammable refrigerants.
If you don't understand something or need help, please contact the dealer
services
2. SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when servicing
a dehumidifier with R290.
2.2.1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimized. For
repair to the refrigerating system, the following precautions shall be complied
with prior to conducting work on the system.

7
2.2.2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the
risk of a flammable gas or vapor being present while the work is being
performed.
2.2.3 General work area
All maintenance staff and others working in the local area shall be instructed
on the nature of work being carried out. Work in confined spaces shall be
avoided. The area around the workspace shall be sectioned off. Ensure that
the conditions within the area have been made safe by control of flammable
material.
2.2.4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to
and during work, to ensure the technician is aware of potentially flammable
atmospheres. Ensure that the leak detection equipment being used is suitable
for use with flammable refrigerants, i.e. no sparking, adequately sealed or
intrinsically safe.
2.2.5 Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any
associated parts, appropriate fire extinguishing equipment shall be available
to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging
area.
2.2.6 No ignition sources
No person carrying out work in relation to a refrigeration system which
involves exposing any pipe work that contains or has contained flammable
refrigerant shall use any sources of ignition in such a manner that it may lead
to the risk of fire or explosion. All possible ignition sources, including cigarette
smoking, should be kept sufficiently far away from the site of installation,
repairing, removing and disposal, during which flammable refrigerant can
possibly be released to the surrounding space. Prior to work taking place, the
area around the equipment is to be surveyed to make sure that there are no
flammable hazards or ignition risks. “No Smoking” signs shall be displayed.
2.2.7 Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before
breaking into the system or conducting any hot work. A degree of ventilation
shall continue during the period that the work is carried out. The ventilation
should safely disperse any released refrigerant and preferably expel it
externally into the atmosphere.
2.2.8 Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the
purpose and to the correct specification. At all times the manufacturer’s

8
maintenance and service guidelines shall be followed. If in doubt consult the
manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable
refrigerants:
– The charge size is in accordance with the room size within which the
refrigerant containing parts are installed;
– The ventilation machinery and outlets are operating adequately and are not
obstructed;
– If an indirect refrigerating circuit is being used, the secondary circuit shall
be checked for the presence of refrigerant;
– Marking to the equipment continues to be visible and legible. Markings and
signs that are illegible shall be corrected;
– Refrigeration pipe or components are installed in a position where they are
unlikely to be exposed to any substance which may corrode refrigerant
containing components, unless the components are constructed of materials
which are inherently resistant to being corroded or are suitably protected
against being so corroded.
2.2.9 Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety
checks and component inspection procedures. If a fault exists that could
compromise safety, then no electrical supply shall be connected to the circuit
until it is satisfactorily dealt with. If the fault cannot be corrected immediately
but it is necessary to continue operation, an adequate temporary solution
shall be used. This shall be reported to the owner of the equipment so all
parties are advised.
Initial safety checks shall include:
-those capacitors are discharged: this shall be done in a safe manner to avoid
possibility of sparking;
-that there are no live electrical components and wiring are exposed while
charging, recovering or purging the system;
-that there is continuity of earth bonding

9
3. PRODUCT OVERVIEW %
1. FRONT VIEW
!!
!
!
!
!
!
Control%panel
Front%shell%
Air%outlet
Air%Filter%
Back%shell
Castors%
Top%
Water%tank
Con?nuous%drainage

10
3.2 FEATURES
●Powerful moisture removal
●Humidity Monitor shows current air humidity
●Auto mode automatically adjusts humidity levels
●A 12-hour timer to set the time of operation
●Effectively removes moisture, dust from the air
●Low power consumption-energy efficient
●Quiet fan has two speed settings
●Auto-Defrost at low temperature
●Auto shut-off/ auto restart
●Electronic control
●Laundry drying function
●Antibacterial Filter
●Continuous drainage or 4.0L water tank

11
3.3 SPECIFICATIONS
4. INSTALLATION
4.1 LOCATION
1. Place the unit on a firm, level surface in an area with at least 30cm of free space
around it to allow for proper air circulation.
2. Never install the unit where it could be subject to:
●Heat sources such as radiators, heat registers, stoves or other products that products
that produce heat.
●In an area where oil or water may be splashed
●Direct sunlight
●Mechanical vibration or shock
●Excessive dust
●Lack of ventilation, such as cabinet or bookcase
●Uneven surface
MODELL
MOR20L-DHE
Dehumification Capacity
20L/D(30℃, RH80%)
Rated Voltage
AC220-240V/50Hz
Max .rated Input Power
Current
378W/2.0A(30℃, RH80%)
Noise
≤45dB(A)
Water Tank Capacity
4L
Maximum Refrigerant
Charge
R290/60g
Net weight
14.5kg
Maximum Design
Pressure
High Side: 3.2MPa,
Low Side:0.7MPa
Minimum Room size
4 m2 (Floor area)
Dimension
343*237*570mm

12
WARNING!
Install the unit in rooms which exceed 4 m².
Do not install the unit in a place where inflammable gas may leak%
NOTE
The manufacture may provide other suitable example or may provide additional information
about the refrigerant odour.%
%
4.2 OPERATING THE DEVICE SAFELY
●Check the device after unpacking for any damages or scratches on it.
●Operate this unit in an ambient temperature from 5°C to 35°C.
●Do not use in the outdoors. This dehumidifier is intended for indoor residential
applications only.
●Do not operate in close proximity to walls, curtains, or other objects that may block
inlet and outlet.
●Keep the air inlet and outlet free of obstacles.
●Adjusting the wind deflector in the upward direction prior to start up.
●If tipped more than 45°, allow the unit to sit upright for at least 24 hours before start
up.
●Keep doors and windows closed for better energy saving.
●Do not operate or store the unit in direct sunlight or rain.
●It is normal for the air outlet to feel warm to touch after continuous operation on hot
days.
●Empty the water tank before moving the device.

13
●Make sure the Water tank is correctly fitted otherwise the unit will not operate properly.
●The dehumidifier starts up in the mode selected when the unit was last used.
●The dehumidifier starts dehumidifying if the room humidity is 3% higher than the
selected humidity.
●There is a protective 3-minutes time delay of the compressor. Wait 3 minutes for the
dehumidifier to resume dehumidification.

14
5. OPERATION
!
5.1 CONTROL PANEL
5.2 FUNCTION KEYS AND INDICATORS
POWER button
Press to switch the machine on or off.
Mode Button
Press to choose Auto and Continuous Drying mode.
Timer button
Sets a time for the unit to automatically start or stop.
ADD
Increasing the desired temperature,humidity and timer setting.
5.
MINUS
Decreasing the desired temperature ,humidity and timer setting.
6.
Lock button
Hold this button to turn child lock function on or off.
7.
Sleep/Reset button
Press to turn sleep mode on or off. Hold this button to reset the
filter
8.
Fan speed button
Press to select fan speed between high and low.
9.
Digital Display
Displays humidity value, Timer setting or Temperature.
○9
○8%
○9
○7%
○5%
○2%
○1%
○6%
○4%
○3

15
5.3 SETTINGS
%%%Power button!
In the standby state, press the power button to turn on, the operation indicator
lights up and the default fan speed is high, and the default humidity is 50%. In
the power-on state, press the power button to turn off, the running indicator
light goes off and the compressor stops immediately, and then the fan shut’s
down after 30 seconds delay.
%%Mode button!
Press the mode key to switch between automatic and dry mode.%
Automatic mode: adjustable humidity, adjustable fan speed.
Drying mode: The compressor will keep working without controlling by
humidity; Fan works in high speed (fan speed and humidity are not
adjustable).%
%Sleep/Reset
Touch the sleep button and the button light will be on to activate the sleep
function. Long press the sleep button to start the filter reset function.%
%%%Timer button
Press the timer button to set the 1-12 hour timing function. Each time you
press this button, the value increase 1 hour, the value displayed on the “88”
display screen.%
In the running state, use the timer function to "turn off the machine
regularly".%
In the standby state, use the timer function to "turn on the machine
regularly".%
Set the time to "00" to cancel the timing function.
Speed
High wind - low wind cycle, press button once to switch and then the
corresponding indicator lights up. In continuously drying mode, sleep mode
and defrosting period, the wind speed can not be changed.
%%Child lock%
Long press the child lock button to turn on or off the child lock function.%

16
6. MAINTENANCE!
6.1 DRAINAGE
There are two ways of removal collected water produced by the unit.
A. Manual draining: Empty water tank by manual.
B. Continuous draining: Use gravity to drain condensate water by attaching a
drain hose.
6.1.1 EMPTYING THE WATER TANK
The water tank built in unit will fill up and shut the unit down once it is full. It
will run again once you empty the water tank and installed properly.
●When the tank is full, The unit will make a buzzing sound, and the
“Water Full” light will turn on.
●Press the POWER button to turn off the unit.
●Pull on the water tank and simply slide out of the body of the
dehumidifier.
●Empty the water into an area with a drain or outside.
●Clean the inside of the tank as well as the outside.
●Replace the empty tank back into the unit.
●Press the POWER button to resume operating.
●If the Water Full light does not extinguish, check that the float is correctly in
place.
%%%%%%%%
% %

17
6.1.2 CONTINUOUS DRAINING
For continuous operation or unattended dehumidification, please connect the
attached drain hose to the unit. Condensate water can be automatically flow
into a bucket or drain by gravity.
●Set the unit in a horizontal surface and stable position.
●Switch off the unit before operating.
Remove the plug of the water outlet opening, and keep it in safe area.
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%
●Securely and properly connect the drain hose and make sure it is not
kinked and clear of obstruction.
●Place the outlet of hose over a drain or bucket and ensure that water
could freely flow out of the unit.
Do not submerge the end of hose into water; otherwise it can cause "Air
Lock" in the hose.
%%%%%%%%%%%%%%%%%%%%% %
6.2 To avoid water spillage:
•As the negative pressure of condensate drain pan is large, tilt the drain
hose downward toward the floor. It is appropriate that the degree of
inclination should exceed 20 degrees.%
Straighten the hose to avoid a trap existing in the hose.%
•CLEANING THE AIR FILTER (every two weeks)
Dust collects on the filter and restricts the airflow. The restricted airflow
reduces the efficiency of the system and if it becomes blocked it can
%%drain-pipe%

18
cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy
cleaning. Do not operate the unit without an air filter, or the evaporator may
be contaminated.
1.Remove the filter frame and take off the filter.
%
%
%
2 .Soak the strainer in warm water at about 40 degrees Celsius. Rinse gently
with a neutral detergent.
Use the vacuum cleaner's brush to gently remove dust from the screen.
%%%%%%%%%%%%%%%%%%%%%%%%%%
%%%%%
3.Put the filter back.
%
%
%% %

19

20
7.TROUBLE SHOOTING %%%
1. FUNCTIONING TEMP.
5°C ≤Ambient Temp. ≤35°C
When the ambient temp is lower or higher than the functioning temp, the
dehumidifier stops.
When 5°C ≤Ambient temp. ≤16°C, the compressor automatically defrosts at
intervals; during defrosting, the compressor stops and the fan keeps running.
2.BEFORE CALLING FOR SERVICE
Before contacting professional service, please review the trouble shooting list
that includes common occurrences that are not the result of a defect in
workmanship or materials.
Problem
Possible Cause
Solution
Not working
No power supply
Connect to a functioning outlet and
switch on
Water Full Indication Flashes
Drain water tank and reset it, or re-
position the water tank to right place
Room temperature ˂5°C,or ˃
35 °C
Self-Protection designed to protect
the unit. Can not work under such
temperature
Bad
functioning
Is the air filter clogged?
Clean the air filter as instructed
Is the intake duct or discharge
duct obstructed?
Remove the obstruction from the
discharge duct or intake duct.
No air intake
Is the filter clogged?
Wash the filter
Loud noise
when
running
Is the machine put in the plat
place?
Put the machine on the plat ground
Is the filter clogged?
Wash the filter
E2
Humidity sensor problem
Change a sensor
LO
Environmental humidity is
below 20%
The dehumidifier shuts down for
self- protection
HI
Environmental humidity is
above 90%
CL
Low temperature protection,
the environmental temperature
<5℃
CH
High temperature protection,
the environmental temperature
>35℃
Table of contents
Other Morris Electric Heater manuals
Popular Electric Heater manuals by other brands

Truma
Truma Ultraheat S 3004 operating instructions

Space-Ray
Space-Ray LTU 160/100-N7 Installation and operation instructions

Intertec Data Systems
Intertec Data Systems CP MULTITHERM DG.A HI operating instructions

Roberts Gorden
Roberts Gorden Vantage TF TF-200 Installation & operation

Hornbach
Hornbach Elektro-Heizlufter 3000 Watt user manual

Chemin'Arte
Chemin'Arte Lounge instruction manual