manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. morse
  6. •
  7. Lifting System
  8. •
  9. morse 515-N-115 User manual

morse 515-N-115 User manual

The Specialist In Drum Handling Equipment
Models 515-N-115 & 515-T-115
Vertical-Lift Drum Pourer, Scale-Equipped,
60”, DC Power Lift and Tilt
Contents
Page
Receiving Procedures. . . . . . . . . . . . . . . . . . . . 1
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety Information. . . . . . . . . . . . . . . . . . . . . 1 - 2
Machine Description. . . . . . . . . . . . . . . . . . . 3 - 4
Operating Instructions. . . . . . . . . . . . . . . . . . . . 5
Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . 5
Receiving Procedures
Every Morse drum handler is inspected prior to shipping. However,
damage may be incurred during transit.
Check for visible damage. If you choose to accept damaged•
freight, always sign noting the damage on the Bill of
Lading.
Document the damage and have the truck driver sign. We•
recommend keeping a digital camera at your receiving dock
for this purpose.
Open packages expeditiously to check the condition of the•
goods. There is only a 24 hour window to notify the carrier
of any concealed damage.
Immediately• report all damage to the shipping company!
Then you may contact Morse for assistance with your
freight claim.
Morse Manufacturing will not be held responsible for any•
damaged freight that is not signed for as damaged.
Limited 2 Year Warranty
Morse drum handling equipment is guaranteed against defects in
workmanship or materials for two years when used properly within
its rated capacity. Warranty does not cover wear from normal use or
damage from accident or abuse. Motors and other purchased parts
carry the warranties of their manufacturers.
For warranty claims, contact your Morse Dealer to obtain a
return authorization number, and for return freight advice. Return
freight must be prepaid.
In all instances, liability is limited to the purchase price paid or to
repairing or replacing the product. Customer assumes liability for
anymodications,unauthorizedrepairsorpartssubstitution.
Operator’s Manual
for Morse Vertical-Lift Drum Pourers
Models 515-N-115 and 515-T-115
Serial Number 242094 to 249854
Safety Information
While Morse Manufacturing Co. drum handling equipment is
engineeredforsafetyandefciency,ahighdegreeofresponsibility
must be placed upon the machine operator to follow safe practices,
based primarily on common sense, upon which true safety
depends.
Failure to follow the safety precautions in this manual can result in
personal injury or property damage. Observe the same precautions
as with similar machinery where carelessness in operating or
maintenance is hazardous to personnel. Carefully read the safety
precautions below and throughout this manual.
Review the Material Safety Data Sheet(s) for the material(s) in
the drum(s) and take all necessary precautions. Safety shoes,
work gloves, hard hat and other personal protective devices are
recommended.
Prior to initial use, inspect all moving parts and test rotation of drum
holder. Perform necessary load test, inspections, operator training,
etc.
MORSE Mfg. Co., Inc. • 727 West Manlius Street • P.O. Box 518 • East Syracuse, NY 13057-0518
Phone: (315) 437-8475 • Fax: (315) 437-1029 • Email: [email protected] • Website: MorseDrum.com
Copyright 2010 - Morse Mfg. Co., Inc. Form PL515-115 (242094-249854) (Updated December 21, 2010 10:39 AM) 1
The Specialist In Drum Handling Equipment
Models 515-N-115 & 515-T-115
Vertical-Lift Drum Pourer, Scale-Equipped,
60”, DC Power Lift and Tilt
Operator’s Manual for Morse Models 515-N-115 and 515-T-115
with Serial Number 242094 to 249854
MorseDrum.com
Copyright 2010 - Morse Mfg. Co., Inc. Form PL515-115 (242094-249854) (Updated December 21, 2010 10:39 AM) 2
Safety Information (continued)
DANGER - Indicates a situation which, if not avoided, will result in serious injury or death.
This signal word is limited to the most extreme situations.
WARNING - Indicates a situation which, if not avoided, could result in serious injury or
death.
CAUTION - Indicates a situation which, if not avoided, can result in damage to the machine.
CAUTION -Do NOT transport with drum raised.
Always lower the drum holder to lowest position before transporting.
DANGER - Stay well clear of power lines.
Never approach a power line. Current in a high voltage line may arc some distance from the wire to
the steel framed, grounded machine.
WARNING - The Vertical-Lift Drum Pourer is designed to handle one drum of the types listed at the
top of page 3 - Machine Description. DO NOT attempt to handle any other type of drum or object.
DO NOT exceed the weight capacity of 800 Lb.
WARNING - Level oors only.
Foroperationonlyonclean,leveloorsofsuitablebearingcapacity.Donotuseonslopedsurfaces,
ramps,irregularordebrisstrewnoors.
WARNING - Do NOT modify the unit.
UndernocircumstancesshouldanymodicationsbemadetotheMorsemachinerywithoutfactory
authorization.Anymodicationsmayvoidthewarranty.Thismachinewasdesignedtoperforma
specicjobandalterationsmayresultininjurytooperatorormachine.
WARNING - No loose tting clothing.
Wearclose-ttingclothingandsafetyequipmentappropriatetothejob.Loosettingclothingmay
become caught on the machinery and cause severe personal injury.
WARNING - Hydraulic uid under pressure can be hazardous.
Escapinghydraulicuidunderpressurecanpenetratetheskin,causingseriousinjury.Avoidthe
hazard by relieving pressure before disconnecting hydraulic lines. Keep hands and body away from
pinholesandnozzles,whichejectuidunderhighpressure.Useapieceofcardboardtosearchfor
leaks. If an accident occurs, see a doctor immediately and inform them of the nature of the accident.
CAUTION - Wear safety shoes.
Wear safety shoes with non-slip soles and hard toe protection.
MorseDrum.com
Copyright 2010 - Morse Mfg. Co., Inc. Form PL515-115 (242094-249854) (Updated December 21, 2010 10:39 AM) 3
The Specialist In Drum Handling Equipment
Models 515-N-115 & 515-T-115
Vertical-Lift Drum Pourer, Scale-Equipped,
60”, DC Power Lift and Tilt
Operator’s Manual for Morse Models 515-N-115 and 515-T-115
with Serial Number 242094 to 249854
Machine Description
The 515 Series Scale-Equipped Vertical-Lift Drum Pourer will pour a drum at up to 60”
high,measuredfromtheoortothelowestpointofahorizontaldrum.Itisdesignedtolift,
transport,anddispensearibbed55-gallonsteeldrum22.5”indiameter,aswellasaber
drum between 22” and 23.5” in diameter. The maximum full-drum capacity is 800 Lb. The
capacity is derated to 500 Lb. for a half-full drum. The half-full rating is based on the tilt
mechanism’s capacity for handling an unbalanced bottom-heavy drum.
Drum Holder Assembly
The MORcinch drum holder assembly (or “saddle assembly”) is the component
on the Vertical-Lift Drum Pourer that is intended to hold the drum. The carriage
assembly moves vertically along the mast, to position the MORcinch drum
holder assembly designed to secure a drum around it’s middle using a cinch
chain and ratchet tightening system. The MORcinch drum holder accepts
accessoriesforhandling a plastic drum,aberdrum,or a smallerdiameter
drum.
Options
A smaller diameter drum can be handled with the correct size 55/30•
Series Diameter Adaptor installed (see Diameter Adaptor literature).
The• Bracket Assembly (Part # 4556-P) is required to handle a
plastic drum without a top rim (see gure 2.1). It is also recommended
to more securely handle a ber drum. You can use the Bracket
Assembly with a 55-gallon plastic, steel or ber drum. The brace
at top and bottom of the drum prevent it from slipping lengthways
through the drum holder. It adjusts for a drum 31” to 39” tall.
The• Top Rim Clamp (Part # 4560-P) grips the upper rim of your drum to
preventitfromslippingthroughthedrumholder(seegure2.2).Tohandle
a 55-gallon plastic drum with top rim, you mustinstalleithertheBracket
AssemblyortheTopRimClamp.YoucanusetheTopRimClampwitha
55-gallonplastic,steelorberdrumwithsuitabletoprim.
Figure 2.2
Plastic drum being lifted
with part number 4560-P
Top Rim ClampAssembly
installed.
Figure 2.1
Plastic drum being lifted with
partnumber4556-PBracket
Assembly installed.
The Specialist In Drum Handling Equipment
Models 515-N-115 & 515-T-115
Vertical-Lift Drum Pourer, Scale-Equipped,
60”, DC Power Lift and Tilt
Operator’s Manual for Morse Models 515-N-115 and 515-T-115
with Serial Number 242094 to 249854
MorseDrum.com
Copyright 2010 - Morse Mfg. Co., Inc. Form PL515-115 (242094-249854) (Updated December 21, 2010 10:39 AM) 4
Controls
The Morse Vertical-Lift Drum Pourer is manually propelled and steered. The drum
lift and tilt controls are powered by a 12V DC motor with a momentary switch.
There are two functions for the operator to control (Figure 3.1):
LIFT and Lower Function for vertical positioning of the drum1.
To raise the drum
Turn the motor on by holding the momentary switch in the on position.
With the motor on, raise the LIFT handle.
To lower the drum
With the motor off, push in the LOWER handle.
TILT Function to control the degree of rotation of the drum2.
To tilt the drum forward for pouring
Turn on the motor by holding momentary switch in the on position.
With the motor on, raise the tilt handle.
To return the drum to vertical position
Turn on the motor by holding momentary switch in the on position.
Push the tilt handle down
WARNING - Watch out for pinch points
Stay clear of moving parts. Operator should remain behind the push handle during the lift operation.
Floor Lock
Theoorlockhandleislocatedontheleftsideofthepushhandle.Pullingtheoorlockhandletowardtheoperatoruntilitlocksinthedown
positionactivatestheoorlock.Whentheoorlockisactivateditpreventsunwantedfreewheelingoftheunit.Floorconditionsdetermine
theeffectivenessoftheoorlock.Theoperatorshouldverifyitsholdingactionbeforedependingonittohold.
Two Types of Scales
The scales are simple to use and to read enabling accurate batching by weight. The touch pads include numbers for tare
entry.Fourloadcellsaccuratelysensetheweightregardlessofthetiltangleofthedrum.Batterysaving“sleep”mode
turns indicator off when scale is not in use.
Display weight to 0.1 Lb. with accuracy of +/-0.2 %
Scale components will be installed and calibrated before leaving the Morse factory. However, the rigors of transportation
may change scale calibration. To assure proper accuracy, the user should employ local scale service personnel to check
the function and calibration of the scale. Cost of on-site calibration is not included in the selling price.
T-Type Scale
Features an intrinsically safe, ultra low power intensity (ULPI) indicator for use in many hazardous areas, approved for
allclasses,groupsanddivisionsofN.E.C.hazardousenvironmentclassications.ThehandpumpedorDCPowered
drum handler with this intrinsically safe weighing system may be used in many hazard areas where ordinary electric
powered equipment would be prohibited.
N-Type Scale
Economical general purpose instrument for use in a variety of weighing applications. NOT for use in hazardous areas.
Powered by six ordinary alkaline D-cell batteries.
“T” Type
Intrinsically safe
scale indicator for
use in hazardous
areas.
“N” Type scale
indicator NOT
for hazardous
environments.
Figure 3.1
MorseDrum.com
Copyright 2010 - Morse Mfg. Co., Inc. Form PL515-115 (242094-249854) (Updated December 21, 2010 10:39 AM) 5
The Specialist In Drum Handling Equipment
Models 515-N-115 & 515-T-115
Vertical-Lift Drum Pourer, Scale-Equipped,
60”, DC Power Lift and Tilt
Operator’s Manual for Morse Models 515-N-115 and 515-T-115
with Serial Number 242094 to 249854
Operating Instructions
Push the Vertical-Lift Drum Pourer to the drum.1.
Using the “LIFT” control as described in “Machine Description2.
- Controls” (page 4), position the drum holder assembly with
the back band at the middle of the drum. With the ratchet plate
swung open and the cinch chain hanging from the chain hook,
pushtheunituntilthebackbandrestsrmlyagainstthedrum.
Some adjustment to the tilt angle of the saddle may be necessary
toensure bandtsushon thedrum.Engage theoorlock.
Attaching the drum:3. Drape the cinch chain across the front
of the drum and engage a chain link into the slot in the ratchet
(Figure 3.2). Turn the ratchet clockwise to tighten cinch chain. If
ratchet turns until the pawl is beyond the last ratchet tooth, turn
the ratchet back and slide the next link into the ratchet slot and
try tightening again. The cinch chain must be held tightly against
the drum with the pawl engaged securely in the ratchet teeth.
Operatetheliftfunctiontoliftdrumclearofoor.Disengageoorlock.Rolltodispensinglocation.NOTE:Donotallowthedrumto4.
impactonoor,pouringstation,etc.oraspillordamagecouldoccur.
CAUTION – Do NOT transport with drum raised.
   ALWAYSLOWERTHEDRUMHOLDERTOLOWESTPOSITIONBEFORETRANSPORTING.
The unit can become unstable when transporting with a raised load.
Lift drum to desired pouring height. Operate the tilt control as described in “Machine Description - Controls” (page 4) to adjust the5.
drumattitude.Theoorlockshouldbeengagedwhiledispensing/draining.
Whendispensingiscomplete,tiltdrumbacktouprightposition.Disengagetheoorlockandlowerthedrumtotransportingheight;6.
about6”offtheoor.
WARNING - Stay clear of raised drum
NEVER allow anyone to be below any part of a raised drum handler or drum. Remain behind the push handle
while handling a drum.
WARNING – Do NOT disengage the cinch chain when drum is off the ground.
   Whenthedrumisintheuprightposition,lowerthedrumtotheoorbeforereleasingthecinchchain.
Pushtheunittothedrumstorageareaandlowertotheoorinanuprightposition.Releasethecinchchainfromtheratchetby7.
applying pressure to the ratchet handle in a clockwise direction with one hand and opening the pawl to free the ratchet with the other
hand. Remove the cinch chain link from the ratchet.
Maintenance
Periodicinspectionforthegeneralconditionofstructuralandmechanicalcomponentsisimperativeforsafeandefcientoperation.1.
Periodically inspect all moving parts, framework, drum holder and contact areas for signs of wear, fatigue, or loosening. Tighten, adjust,2.
or replace parts as necessary to prevent failure and maintain proper function.
Inspectthehydraulicsystemforoildrips,hosedamage,orothersignsofwear.Inspectthelevelofthehydraulicuid.Replaceany3.
parts that show signs of wear.
Greasewheelbearingsperiodically.Oilorgreaseallmovingparts,including:thegearsandsprocketsinthetiltdrive,andtheratchet4.
and pawl.
Worn or damaged parts must be properly replaced with the correct, genuine Morse parts.5.
Hydraulic pump is shipped lled with Noco Premium plus automatic transmission uid d/m. Material safety data sheet (msds) is6.
available online. Change oil yearly, sooner depending on dirty conditions or outdoor use. Replace oil with Mobil dte 24 or equivalent for
indoor use (Mobil dte 13 for outdoor use).
Figure 3.2

This manual suits for next models

3

Other morse Lifting System manuals

morse 92 Series User manual

morse

morse 92 Series User manual

morse 86 User manual

morse

morse 86 User manual

morse 400A-60-110 User manual

morse

morse 400A-60-110 User manual

morse 185A-HDSS User manual

morse

morse 185A-HDSS User manual

morse 195A Series User manual

morse

morse 195A Series User manual

morse 400A-72SS-110 User manual

morse

morse 400A-72SS-110 User manual

morse Kontrol-Karrier 185A User manual

morse

morse Kontrol-Karrier 185A User manual

morse 520-114 User manual

morse

morse 520-114 User manual

morse 400A-96SS-114 User manual

morse

morse 400A-96SS-114 User manual

morse 410-114 User manual

morse

morse 410-114 User manual

morse 510-120 User manual

morse

morse 510-120 User manual

morse 510M User manual

morse

morse 510M User manual

morse 400A-96-115 User manual

morse

morse 400A-96-115 User manual

morse 82A-GT Series Operator's manual

morse

morse 82A-GT Series Operator's manual

morse 400A-96-110 User manual

morse

morse 400A-96-110 User manual

morse 400AM-60 User manual

morse

morse 400AM-60 User manual

morse 185A-GR User manual

morse

morse 185A-GR User manual

morse 400A-60-125 User manual

morse

morse 400A-60-125 User manual

morse 400AM-72-124 User manual

morse

morse 400AM-72-124 User manual

morse 525M-T User manual

morse

morse 525M-T User manual

morse 400AM-72-114 User manual

morse

morse 400AM-72-114 User manual

morse 515-N-125 User manual

morse

morse 515-N-125 User manual

morse 400A-72-120 User manual

morse

morse 400A-72-120 User manual

morse 82H-124 User manual

morse

morse 82H-124 User manual

Popular Lifting System manuals by other brands

Britec GENERATOR HOIST V22 user guide

Britec

Britec GENERATOR HOIST V22 user guide

Atlas Equipment PV-15PX manual

Atlas Equipment

Atlas Equipment PV-15PX manual

Car-O-Liner Speed instruction manual

Car-O-Liner

Car-O-Liner Speed instruction manual

Mohawk A-7 manual

Mohawk

Mohawk A-7 manual

AJ 31078 operating instructions

AJ

AJ 31078 operating instructions

Liko Likorall 242 S Instruction guide

Liko

Liko Likorall 242 S Instruction guide

Stratus SAE-C9P Installation, operation, and parts manual

Stratus

Stratus SAE-C9P Installation, operation, and parts manual

Refco LFT-230 instruction manual

Refco

Refco LFT-230 instruction manual

Chiltern Invadex Wispa Mobile Series user guide

Chiltern Invadex

Chiltern Invadex Wispa Mobile Series user guide

Clarke Strong Arm CML2 Operating & maintenance instructions

Clarke

Clarke Strong Arm CML2 Operating & maintenance instructions

The Handy 20707G INSTRUCTIONS, PARTS DRAWING, PART LIST

The Handy

The Handy 20707G INSTRUCTIONS, PARTS DRAWING, PART LIST

progressive automations FLT-03-2-2 manual

progressive automations

progressive automations FLT-03-2-2 manual

Nexus 21 AL-125 installation instructions

Nexus 21

Nexus 21 AL-125 installation instructions

Floe PWC1300 Quick start quide

Floe

Floe PWC1300 Quick start quide

POWERTEX PAPH-S1 Series user manual

POWERTEX

POWERTEX PAPH-S1 Series user manual

Servonaut AMO manual

Servonaut

Servonaut AMO manual

Arjo Calypso Instructions for use

Arjo

Arjo Calypso Instructions for use

twin busch TW M-04 Installation, operation and maintenance manual

twin busch

twin busch TW M-04 Installation, operation and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.