STANDARDS TO FOLLOW
DESCRIPTION
DEVICE INSTALLATION
FACTORY RESET AND SET MANAGEMENT CARD
ADMIN SETTING ON KEYPAD
OPEN DOOR AS USER
PRODUCT INSTALLATION
REMOVE ALARM
ADMIN CARD OPERATION
SOUND AND LIGHT INDICATION
ADVANCED APPLICATION
. SAFETY INSTRUCTIONS
. DEVICE
. INSTALLATION AND CONNECTIONS
. CONFIGURATIONS
. CONTENT . SAFETY INSTRUCTIONS
INDEX STANDARDS TO FOLLOW
2B
FEATURES
ATTENTION:
This product is certified in accordance with European Community
(EC) safety standards.
This product complies with Directive 2011/65/EU of the European
Parliament and of the Council, of 8 June 2011, on the restriction of
the use of certain hazardous substances in electrical and electronic
equipment.
(Applicable in countries with recycling systems).
This marking on the product or literature indicates that the product
andelectronicaccessories(eg.Charger,USBcable,electronicmaterial,
controls, etc.) should not be disposed of as other household waste at
the end of its useful life. To avoid possible harm to the environment
or human health resulting from the uncontrolled disposal of waste,
separate these items from other types of waste and recycle them
responsibly to promote the sustainable reuse of material resources.
Home users should contact the dealer where they purchased this
product or the National Environment Agency for details on where and
how they can take these items for environmentally safe recycling.
Business users should contact their vendor and check the terms and
conditions of the purchase agreement. This product and its electronic
accessories should not be mixed with other commercial waste.
This marking indicates that the product and electronic accessories
(eg. charger, USB cable, electronic material, controls, etc.) are
susceptible to electric shock by direct or indirect contact with
electricity. Be cautious when handling the product and observe all
safety procedures in this manual.
2B
TECHNICAL SPECIFICATIONS
3A
3B
WIRES
CONNECTIONS SCHEME

A B
ENEN
. SAFETY INSTRUCTIONS . DEVICE
STANDARDS TO FOLLOW DESCRIPTION
FEATURES
MLS4 is a waterproof standalone access control, reading EM&HID card, it uses advanced
Microprocessor, with high-capacity flash memory for 10000 users. Users can be added and
deleted via admin card, very simple to operate. The infrared remote control make the device
not only have alarm, protection, anti-passback function but also allows to install two units
interlocked and add and delete the user on the device.
Besides, it has a low power consumption, anti-theft alarm and door release button. All these
characteristics make it convenient, safe and reliable.
Feature Description
Waterproof Design Rainproof, moistureproof , durable
Ultralow power consumption Longer working life, more stable performance
Large capacity 10000 user cards
Wiegand reader Can be used as wiegand 26 output reader
External reader connection Can be connected an EM/IC/HIDwiegand 26 output reader
Two devices interlocked Two devices can be interlocked online
Anti-passback Single door or two doors anti-passback
TECHNICAL SPECIFICATIONS
• Power Supply 12Vdc ± 10%
• Static current <30mA
• Card maximum reading distance 5 ~ 8cm
• Operating temperature -25°C ~ 55°C
• Operating humidity 20% ~ 98%
• Output load blocking 2A
• Alarm Output load 2A
• Management card 2 units
• It is important for your safety that these instructions are followed.
• Keep these instructions in a safe place for future reference.
• The ELECTROCELOS S.A. is not responsible for the improper use of the product,
or other use than that for which it was designed.
• The ELECTROCELOS S.A. is not responsible if safety standards were not taken
into account when installing the equipment, or for any deformation that may
occur.
• The ELECTROCELOS S.A. is not responsible for insecurity and malfunction of the
product when used with components that were not sold by the them.
• This product was designed and manufactured strictly for the use indicated in
this manual.
• Any other use not expressly indicated may damage the product and/or can
cause physical and property damages, and will void the warranty.
• Do not make any changes to the automation components and/or their
accessories.
• The customer shall not, under any circumstances, attempt to repair or tune the
automatism. Must call qualified technician only.
•Theinstallermusthavecertifiedprofessionalknowledgeatthelevelofelectronic.
He should also be able to perform electrical connections in compliance with all
applicable regulations.
• The installer should inform the customer how to handle the product in an
emergency and provide him the manual.
• This device can be used by children 8 year old or older and persons whose
physical, sensory or mental capacities are reduced, or by persons without
experience or knowledge if they have received supervision or instructions on
the use of the device in a safe manner and understood the hazards involved.
Children should not play with the device. Cleaning and maintenance by the user
must not be carried out by unsupervised children.
• Automatism powered by very low safety voltage, with electronic board/control
board/control unit.
• Before installing, the installer must verify that the temperature range indicated
on the automatism is appropriate to the location of the installation.
• In order to protect the electrical cables against mechanical stress, you should
use conduit for the electrical wires, essentially on the power cable.

A B
ENEN
. INSTALLATION AND CONNECTIONS . INSTALLATION AND CONNECTIONS
DEVICE INSTALLATION
WIRES
CONNECTIONS SCHEME
1 • Drill the holes according to the distance and the dimension on the back cover, or install
the distributing box
2 • Pass the cable through the hole, connect the necessary wires and insulate the unused
wires with insulation tape to safeguard a short circuit
3 • Fix the back cover on the wall with special screws
4 • Fix the front cover to the back cover with the screws
Note • Please check all wires and install front cover carefully before power on.
MLS4
M2 Relay
12Vdc/3A
Extra Energy
NC
NC COM NO PUSH GND +12V
NC
Orange
Orange
Connect Extra Energy
Extra Power Scheme
12Vdc Extra Power Standalone for single door mode scheme
Power off - the lock keep
unlocking
Power on - the lock keep
unlocking
+12V
Door Contact
Exit Button
Alarm
Reset External Reader
Purple
Purple
Blue
Blue
Black Red Brown Yellow Gray White Green Pink Pink
COM
COM
NO
NO
GND Push
GND
D_IN
D1
D1
+12V
GND
GND
+12V
ALARM-
OPEN
D0
D0
RESET
Line
sequence Marks Color Description
1RESET Pink RESET
2GND Pink RESET
3D Green WG output line D
4D White WG output line D
ALARM- Gray Alarm
OPEN Yellow Exit button
D_IN Brown Door contact switch
V Red V Input
GND Black GND
NO Blue Relay NO end
COM Purple Relay Com
NC Orange Relay NC end

A B
ENEN
. INSTALLATION AND CONNECTIONS . INSTALLATION AND CONNECTIONS
CONNECTIONS SCHEME CONNECTIONS SCHEME
NC
Orange
Exit Button
Alarm
Reset External Reader
Access Controller
12V Power Supply
Purple Blue Black Red Brown Yellow Gray White Green Pink Pink
COM
NO
GND
D_IN
D1
D1
D1
+12V
+12V
GND
GND
GND
+12V
ALARM-
OPEN
D0
D0
D0
RESET
Power off - the lock keep
unlocking
Power on - the lock keep
unlocking
NC
NC
RESET
Orange
Exit Button
Alarm
Reset External Reader
12V Power Supply
Purple Blue Black Red Brown Yellow Gray White Green Pink Pink
COM
COM
GND
NO
NO
D0
GND
GND
D1
D_IN
D_IN
OPEN
D1
D1
GND
D1
+12V
GND
GND
GND
COM
+12V
+12V
ALARM-
ALARM-
ALARM-
+12V
OPEN
OPEN
D_IN
D0
D0
NO
D0
RESET
RESET
NC
Power off - the lock keep
unlocking
Power on - the lock keep
unlocking
12Vdc Common Power Standalone for single door mode scheme
12Vdc Common Power Two units interlocked for two doors scheme
Anti-passback for two doors scheme
Wiegand reader mode scheme
12Vdc Common Power Two units interlocked for single door scheme
Anti-passback for single door scheme
NC
Orange Purple Blue Black Red Brown Yellow Gray White Green Pink Pink
COM
NO
GND
D_IN
D1
GND
+12V
ALARM-
OPEN
D0
RESET
Orange PinkPurple PinkBlue GreenBlack WhiteRed GrayBrown YellowYellow BrownGray RedWhite BlackGreen BluePink PurplePink Orange
Door Contact Door Contact
MLS4
MLS4
MLS4 MLS4
MLS4

A B
ENEN
. CONFIGURATION
FACTORY RESET AND SET MANAGEMENT CARD PRODUCT INSTALLATION
. CONFIGURATION
Connect the two pink wires, then turn on the power. After the sound “didi”, Factory reset is
finished. When indication LED turns green, it means you can set the two admin cards. Read
the first card as admin add card. After that read the second card as admin delete card. Then
LED turns red flash, and after that, the device can work normally.
Note • Reset factory default won’t delete user cards. If you present the same card on the
second read, the device will whistle 3 consecutive times indicando erro. Then you can
continue present another card. If doesn't happen operations within 10seconds, the device
will enter working mode automatically and the parameter reset to factory default.
Add users by remote control:
Delete users via remote control:
Safe mode setting:
ADMIN SETTING ON KEYPAD
Entering admin
operating mode
Press factory default: 999999
Note • All the below operations need to be under programming
mode.
master code
*#
Change the master
code
Press
Note • Master Code length:6~8 digits
Add consecutive
number card
Press
Add consecutive user card numbers, card quantity 1-9999, green
fast flash
Delete all users Press
Note • This operation will delete all users, but admin cards won’t
be deleted.
Use ID Number to add
user
Press
Note • 1 Card number must be 8 or 10 digits. If the card number
has less than 8 or 10 digits, type 0 before the card number 2
press #confirm, press last #finish, press *exit.
Read card to add user Press
Read card to delete
user Press
Normal mode (factory
default) Press
Dead mode
Press
Read invalid cards 10 times continuously within 10 minutes it will
take the device to a dead status for 10 minutes.
Alarm mode
Press
Read invalid cards 10times continuously within 10 minutes it will
activate both external alarm and built-in alarm sound.
Set Door open time
Press
Range "0~99 seconds", 0mS equates 50mS.
Use card NO. to delete
user
Press
cards quantity
2000
1#
#
#
#
#
#
read card
1#
read card
2
3
3
3
4
0
1
2
0~99
8 or 10 digits card number
8 or 10 digits card number
2
read card #
read card #
#
#
#
8 or 10 digits card number
new code
0#repeat new code #
card number
1#card number #
...
...
Set alarm time
Press
Note • Range "0~3 minutes", 1 minute by factory default.
#
50~3

A B
ENEN
. CONFIGURATION
PRODUCT INSTALLATION OPEN DOOR AS USER
. CONFIGURATION
Set Red light mode:
Add user:
External alarm and built-in alarm both sound
Inside buzzer alarm after door close
Delete user:
Set Interlock:
Set Anti-passback:
Static off mode Press Read user card Read a valid user card. Door will be open,but admin card can’t
open the door.
Press
Read
Close the door and read
Press
Close interlock
(factory default) Press
Disable anti-passback
(factory default) Press
Enable hosting anti-
passback mode Press
#
#
#
#
#
#
6
7
8
8
0
0
0
1
Static on mode
(factory default) Press
Open interlock Press
#
#
6
7
1
1
Enable anti-passback
subsidiary mode
Press
Note • Details will be illustrated in Advanced Application below.
#
8 2
ADMIN CARD OPERATION
REMOVE ALARM
read admin add card
user card
user card
read admin delete card
read admin delete card
read admin add card
read user card 1
admin card
admin card
read user card 1 read user card 2
read user card 2
admin PIN
admin pin
... ,
... ,
finally
alarm will be removed.
alarm will be removed.
or type
or type
finally
exit.
,
,
,
,
exit.
OPERATION LED COLOR BUZZER
Initialization Orange Bip Bip
Static Red Flash
Valid key Long bip
Enter programme Red Long bip
Setting Orange Bip
Exit Red Flash Long bip
Operation Failed Bip Bip
Lock open Green Long bip
Alarm Red Quick Flash Alarm
Add sequential No. card Green Quick Flash
SOUND AND LIGHT INDICATION

A B
ENEN
1• Two devices for single door
Install one device at indoor and the other at outdoor. Indoor device it’s the
controller and the outdoor device works as reader. The difference between two
interlocked devices for a single door and standalone for single is below:
1.1 • Add users on both devices. Both indoor user data and outdoor data can be
shared. Users can be added up to 20000.
1.2 • The setting of the two device must be the same. When admin PIN setting is
different, outdoor device can’t open the door with saved users data.
2• Two devices interlocked for two doors
Install two controllers for two doors in way to control two locks separately, set
interlocked for two devices, open door contact. One door is locked when the
other door is open. The device can’t control another electric lock and saved
data can’t be shared between different devices. This function mainly apply for
bank, prison etc.
3• Anti-passback for Single door
Install a common reader outdoor (or use this device without any card No. for
reader). Install this device outdoor and set it as anti-passback host mode. In
this case, the two devices consist of an anti-passback system for single door,
mainly apply to controlling enter and exit for single door. Operation details
below:
3.1 • Set the necessary functions and add an user card on the host device.
3.2 • Users can only present the card on the external reader to enter, and
then present the card on the host device to exit. Users can't enter or exit 2
consecutive times.
. CONFIGURATION
ADVANCED APPLICATION ADVANCED APPLICATION
. CONFIGURATION
4• Anti-passback for two doors
Install one device on Door 1 in auxiliary anti-passback mode. Install one device
on Door 2 in hosting anti-passback mode. In this case, the two devices consist in
a anti-passback for two doors, mainly apply for one-way in and out for double
doors like a parking. Functions as follows:
4.1 • Set the necessary functions and add an user card on the host device.
4.2 • Users can only present the card on the auxiliary device to enter, and then
present the card on the hosting device to exit. Users can't enter or exit at 2
consecutive times.
Other manuals for MLS4
2
Table of contents
Other Motorline professional IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

Third Millennium
Third Millennium OC1 manual

KALE KILIT
KALE KILIT KD050/10-360 INTRODUCTION AND USER MANUAL

AAS
AAS Advantage DKE 26-100sg Installation and programming instructions

Videosec
Videosec TYW-CODMF1 user manual

TH COMMUNICATIONS
TH COMMUNICATIONS MZ11D7 quick start guide

Roger
Roger MC16-PAC-1-KIT installation manual

Moniteq
Moniteq Crypto-Lock CC-8521B instruction manual

eKey
eKey FS OM Crestron Series operating instructions

Visonic Networks
Visonic Networks TAG-IN-A-BAG Installation and programming guide

VisAccess
VisAccess VXS-10 installation instructions

FingerTec
FingerTec AC900 installation guide

TimeTec
TimeTec ProFace X installation guide